Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 66.82.9.125.1000 is a Series 66 flange-mounted electromechanical power relay featuring a 125 V DC coil, two changeover contacts, a 30 A normally open contact rating and Faston 250 terminals for industrial electrical switching and automation applications.
The Finder 66.82.9.125.1000 is a high-current electromechanical power relay from the Finder Series 66, designed for reliable electrical load switching in industrial automation, machinery and power control equipment. Featuring a 125 V DC operating coil and two changeover contacts (2 CO / DPDT), it provides a practical solution for controlling two independent electrical circuits.
With a 30 A normally open contact rating and a 10 A normally closed contact rating, the Finder 66.82.9.125.1000 supports demanding industrial switching applications. Its flange-mounted construction and Faston 250 quick-connect terminals simplify integration into electrical panels, machinery and original equipment manufacturer (OEM) assemblies.
The relay also benefits from reinforced insulation between the coil and contacts, helping maintain electrical separation between the DC control circuit and connected loads. Its robust electromagnetic design makes it suitable for industrial applications requiring dependable switching, straightforward installation and compatibility with 125 V DC control supplies.
The Finder 66.82.9.125.1000 operates using a DC electromagnetic coil that controls two changeover contact sets. When the rated 125 V DC control voltage is applied, the relay transfers its contacts from the normally closed positions to the normally open positions. This allows two separate electrical circuits to be switched simultaneously while maintaining electrical separation between the control supply and the connected loads.
The relay is particularly suited to electrical control systems using 125 V DC supplies, including industrial power management equipment and machinery control assemblies. Its high-current contacts provide switching capability for appropriately rated AC and DC loads, while the flange-mounted housing and Faston terminals support straightforward equipment integration.
When selecting the relay for motor, inductive or DC loads, the relevant utilisation category and breaking-capacity limits should be considered. The 30 A contact rating must not be assumed to apply to every load type or operating voltage.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Manufacturer | Finder | |
| Series | 66 Series | |
| Model | 66.82.9.125.1000 | |
| Product type | Electromechanical power relay | |
| Relay family | 66.82 flange-mounted power relays | |
| Contact configuration | 2 CO (DPDT) | |
| Number of poles | 2 | |
| Contact operation | Double-pole changeover | |
| Nominal coil voltage | 125 V DC | |
| Coil type | DC electromagnetic coil | |
| Nominal coil consumption | 1.7 W | |
| DC coil operating range | 0.8–1.1 × nominal voltage | |
| DC coil operating voltage | 100–137.5 V DC | |
| DC coil holding voltage | 0.5 × nominal voltage | |
| DC coil must drop-out voltage | 0.1 × nominal voltage | |
| Rated normally open contact current | 30 A | |
| Rated normally closed contact current | 10 A | |
| Rated contact voltage | 250 V AC | |
| Maximum AC switching voltage | 440 V AC | |
| Rated AC1 load (NO) | 7,500 VA | |
| Rated AC1 load (NC) | 2,500 VA | |
| Rated AC15 load at 230 V AC (NO) | 1,200 VA | |
| Single-phase motor rating at 230 V AC (NO) | 1.5 kW | |
| DC1 breaking capacity at 24 V DC (NO) | 25 A | |
| DC1 breaking capacity at 110 V DC (NO) | 0.7 A | |
| DC1 breaking capacity at 220 V DC (NO) | 0.3 A | |
| Minimum switching load | 1,000 mW (10 V / 10 mA) | |
| Coil-to-contact insulation | Reinforced | |
| Creepage and clearance distance | 8 mm | |
| Impulse withstand voltage | 6 kV | |
| Dielectric strength between open contacts | 1,500 V AC | |
| Mechanical endurance | 10 million operations | |
| Electrical endurance at rated AC1 load | 100,000 operations | |
| Operating ambient temperature | −40 to +70 °C | |
| Environmental protection category | RT II | |
| Mounting type | Flange / chassis mounting | |
| Connection type | Faston 250 quick-connect terminals | |
| Terminal size | 6.3 × 0.8 mm | |
| Relay operation | Monostable, non-latching | |
| Application category | Industrial power switching and control |
The Finder 66.82.9.125.1000 is a flange-mounted electromechanical power relay used for switching electrical loads in industrial automation, machinery, power management systems and electrical control panels.
This relay operates using a 125 V DC electromagnetic coil with a nominal consumption of 1.7 W. The standard Series 66 DC coil operating range is approximately 100–137.5 V DC.
The relay features 30 A normally open contacts and 10 A normally closed contacts, with a rated contact voltage of 250 V AC and a maximum AC switching voltage of 440 V AC. The permissible switching current depends on the load category.
DPDT means double-pole double-throw. The relay contains two changeover contact sets, allowing two independent circuits to switch between normally closed and normally open connections when the coil is energised.
The relay is designed for flange or chassis mounting and uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm, enabling convenient electrical connections and secure installation in industrial equipment.
Finder Series 66 power relays combine dependable high-current switching, reinforced electrical insulation and practical flange-mounted installation to support reliable electrical control in industrial machinery, commercial equipment and automation systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.