Finder 66.82.9.048.0300 – 66 Series Power relays.
The Finder 66.82.9.048.0300 is a high-current electromagnetic power relay from the Finder 66 Series, designed for industrial automation, electrical control and power switching applications. Featuring a 48 V DC operating coil and two normally open contacts (DPST-NO / 2 Form A), it enables two electrical circuits to be switched simultaneously using a single control signal.
The Finder 66.82-0300 configuration provides a 30 A rated contact current and is designed for appropriately rated industrial electrical loads. Its normally open contacts close when the coil is energised and return to their open positions when the coil supply is removed.
With Faston 250 quick-connect terminals and a top flange mounting arrangement, the Finder 66.82.9.048.0300 is suitable for integration into compatible machinery, electrical equipment and industrial control assemblies. Its DC-operated electromagnetic design is particularly useful in systems employing a 48 V DC control supply.
The Finder 66.82.9.048.0300 uses a 48 V DC electromagnetic coil to operate two normally open power contacts. When the coil is energised, both contacts close, completing their respective electrical circuits. When the coil supply is removed, the relay's return mechanism opens both contacts.
This DPST-NO configuration enables two separate electrical loads or control circuits to respond to one switching command. The 30 A contact rating supports suitable industrial switching applications, provided that the connected loads remain within the manufacturer's specified ratings for voltage, current and utilisation category.
The relay's Faston 250 terminals and top flange mounting support integration into industrial equipment. For replacement applications, the coil voltage, contact configuration, mounting dimensions and electrical ratings should be checked against the existing relay and equipment requirements.
The 48 V DC coil rating describes the voltage required to operate the relay, not the voltage or current that its contacts can switch. DC load switching capacity must be evaluated separately from the relay's AC contact ratings.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Switching Current (A) | 30 A | |
| Load Voltage | 440 V AC | |
| Manufacturer | Finder | |
| Series | 66 Series | |
| Manufacturer part number | 66.82.9.048.0300 | |
| Product type | Electromagnetic power relay | |
| Relay configuration | 66.82-0300 | |
| Contact arrangement | DPST-NO / 2 Form A | |
| Number of poles | 2 | |
| Number of normally open contacts | 2 | |
| Rated contact current | 30 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 440 V AC | |
| Rated switching capacity (AC1) | 7500 VA | |
| Rated switching capacity (AC15, 230 V AC) | 1200 VA | |
| Nominal coil voltage | 48 V DC | |
| Coil supply type | DC | |
| Contact material | Silver cadmium oxide (AgCdO), standard .0300 configuration | |
| Operating principle | Electromagnetic, monostable | |
| Mounting arrangement | Top flange / chassis mounting | |
| Terminal type | Faston 250 quick-connect | |
| Terminal dimensions | 6.3 × 0.8 mm | |
| Application | Industrial electrical control and power switching |
The Finder 66.82.9.048.0300 is an electromagnetic power relay designed to switch two normally open electrical circuits in industrial automation, machinery control and auxiliary power applications.
The relay has a 48 V DC nominal coil voltage. The applied control supply must match the manufacturer's specified DC coil operating requirements.
The relay has two normally open contacts (2 NO), described as a DPST-NO or 2 Form A configuration. Both contacts close when the coil is energised and open when it is de-energised.
The Finder 66.82-0300 configuration has a 30 A rated contact current. Actual switching capacity depends on the load voltage, electrical characteristics and applicable manufacturer ratings.
No. The .0300 configuration provides two normally open contacts rather than two changeover contacts. A DPDT relay should be selected where normally closed switching paths are also required.
The standard Finder 66.82-0300 configuration uses silver cadmium oxide (AgCdO) contact material, which is used in industrial power switching applications.
The relay features a top flange / chassis mounting arrangement and Faston 250 quick-connect terminals for electrical connections.
The relay uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm, designed for use with appropriately sized mating connectors.
No. It uses a monostable electromagnetic operating mechanism. Both normally open contacts return to their open positions when the coil is de-energised.
No. The .9.048 coil designation identifies a 48 V DC coil. An appropriately specified AC-coil relay is required for an AC control supply.
Not automatically. The 30 A contact rating must be interpreted alongside the manufacturer's applicable load and voltage specifications. DC switching capacity can differ significantly from AC switching capacity.
Finder 66 Series power relays are designed for industrial electrical control and power switching applications. The Finder 66.82.9.048.0300 combines a 48 V DC operating coil, two 30 A normally open contacts and Faston quick-connect terminals in a flange-mounted construction for compatible industrial control installations.