Why Choose the Finder 66.22.9.006.0600 Industrial Power Relay?

The Finder 66.22.9.006.0600 is a high-current 30 A, two-pole normally open (DPST-NO) PCB-mounted power relay designed for industrial automation, electrical power switching and electronic control equipment. Part of the Finder 66 Series, this specialised relay combines substantial switching capacity with increased contact separation and reinforced insulation between its coil and contact circuits.

Featuring a 6 V DC nominal operating coil and two independent normally open contacts, the Finder 66.22.9.006.0600 allows two electrical circuits to be switched simultaneously from a single control signal. Its .0600 configuration provides normally open contacts with a separation greater than 1.5 mm, making it suitable for applications requiring increased contact-opening distance.

The relay provides a 30 A nominal contact rating, 250 V AC rated contact voltage and 7,500 VA AC1 switching capacity. With 440 V AC maximum switching voltage, reinforced coil-to-contact insulation and bifurcated PCB solder terminals, it is designed for integration into industrial machinery, power control assemblies and high-current electronic switching equipment.

Key Advantages

  • 30 A nominal contact rating for demanding electrical power switching.
  • Two normally open contacts (DPST-NO) enable simultaneous switching of independent circuits.
  • 6 V DC operating coil for compatible low-voltage electronic control systems.
  • Contact separation greater than 1.5 mm provides increased open-contact distance.
  • 7,500 VA AC1 switching capacity for suitable resistive AC loads.
  • 440 V AC maximum switching voltage for appropriately rated applications.
  • Reinforced insulation between coil and contacts supports separation of control and load circuits.
  • 8 mm creepage and clearance distances between coil and contacts.
  • 6 kV impulse withstand voltage between coil and contacts.
  • PCB mounting with bifurcated solder terminals provides secure integration into electronic assemblies.
  • Silver-cadmium oxide (AgCdO) contacts support reliable industrial switching.
  • Suitable for industrial machinery, power electronics, heating systems and automation equipment.

Key Features

  • Finder 66 Series industrial power relay.
  • DPST-NO / 2 Form A contact configuration.
  • Two independent normally open contacts.
  • 30 A rated contact current.
  • 6 V DC nominal coil voltage.
  • 250 V AC rated contact voltage.
  • 440 V AC maximum switching voltage.
  • 7,500 VA AC1 switching capacity.
  • Contact gap greater than 1.5 mm.
  • AgCdO contact material.
  • 21 Ω nominal coil resistance.
  • 1.7 W nominal DC coil consumption.
  • Reinforced coil-to-contact insulation.
  • 6 kV coil-to-contact impulse withstand voltage.
  • 8 mm coil-to-contact creepage and clearance distances.
  • PCB mounting with bifurcated solder terminals.
  • Electromagnetic, monostable operation.
  • Standard version without integrated LED, test button or coil suppression diode.

High-Current Normally Open Switching with Increased Contact Separation

The Finder 66.22.9.006.0600 operates using an electromagnetic coil energised by a 6 V DC control supply. When the coil is energised, its two normally open contact sets close, allowing current to flow through the connected circuits. When the coil is de-energised, both contacts return to their open positions.

Unlike the standard Finder 66.22.9.006.0000, which has two changeover contacts, the 66.22.9.006.0600 has two normally open contacts only. This distinction is important when selecting a relay for an existing PCB or control circuit, because the two configurations provide different switching functions and must not be treated as directly interchangeable.

The .0600 contact configuration incorporates an open-contact gap greater than 1.5 mm. This increased separation is intended for applications requiring a larger physical distance between open contacts. Whether the relay provides an appropriate disconnection function depends on the applicable installation standards, overvoltage category and complete equipment design.

With a 30 A contact rating and 7,500 VA AC1 switching capacity, the relay supports high-current resistive-load switching. Its 250 V AC rated contact voltage and 440 V AC maximum switching voltage provide flexibility for appropriately rated electrical equipment. Inductive loads, motors and DC circuits must be assessed against the applicable load-specific ratings.

Reinforced insulation between the operating coil and contact circuits provides electrical separation between the low-voltage control system and the switched load. The relay's 8 mm creepage and clearance distances and 6 kV impulse withstand rating support integration into equipment requiring suitable insulation coordination.

The PCB-mounted construction uses bifurcated through-hole solder terminals for direct installation onto a printed circuit board. The PCB must be designed with suitable conductor dimensions, copper thickness, thermal management and electrical clearances for the intended current and operating environment.

Typical Applications

  • Industrial power switching and electronic control assemblies.
  • 6 V DC relay driver and control circuits.
  • High-current PCB-mounted switching equipment.
  • Industrial automation and machinery control.
  • Electrical equipment requiring increased open-contact separation.
  • Industrial heating and resistive-load control.
  • Power generation and standby generator control equipment.
  • Industrial ovens, boilers and process heating systems.
  • Air conditioning and HVAC power control.
  • Industrial washing machines and appliance control boards.
  • Motor and auxiliary power switching where the load ratings permit.
  • Replacement of compatible Finder 66.22 normally open relay variants.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type PCB / pins
Switching Current (A) 30 A
Load Voltage 440 V AC
Mounting Type PCB
Manufacturer Finder
Series 66 Series
Model 66.22.9.006.0600
Manufacturer part number 66.22.9.006.0600
Product type Industrial electromagnetic power relay
Contact configuration DPST-NO / 2 Form A
Number of poles 2
Number of normally open contacts 2
Rated contact current 30 A
Maximum peak contact current 50 A
Rated contact voltage 250 V AC
Maximum switching voltage 440 V AC
Rated switching capacity (AC1) 7,500 VA
Minimum open-contact gap Greater than 1.5 mm
Nominal coil voltage 6 V DC
Coil supply type DC
Nominal coil resistance 21 Ω
Nominal coil consumption 1.7 W
Contact material Silver-cadmium oxide (AgCdO)
Contact circuit option Normally open contacts with increased contact separation
Option code .0600
Test button Not included
LED indicator Not included
Coil suppression diode Not included
Relay operation Electromagnetic, monostable
Mechanical endurance 10 million cycles
Electrical endurance at rated AC1 load 100,000 cycles
Typical operate time 8 ms
Typical release time 10 ms
Coil-to-contact insulation Reinforced
Coil-to-contact creepage distance 8 mm
Coil-to-contact clearance distance 8 mm
Coil-to-contact impulse withstand voltage 6 kV
Coil-to-contact dielectric strength 4,000 V AC
Operating ambient temperature −40 to +70 °C
Mounting type Printed circuit board (PCB)
Connection type Bifurcated through-hole solder terminals
Approximate dimensions 51.5 × 33.5 × 31 mm
Application category Industrial power switching and electronic control equipment

Frequently Asked Questions

What is the Finder 66.22.9.006.0600 used for?

The Finder 66.22.9.006.0600 is a 30 A, two-pole normally open industrial power relay used for high-current electrical switching in PCB-mounted industrial equipment, automation systems and electronic power control assemblies.

What coil voltage does the Finder 66.22.9.006.0600 require?

The relay has a nominal 6 V DC operating coil, approximately 21 Ω nominal coil resistance and 1.7 W nominal coil consumption. It should be operated within Finder's specified coil voltage limits.

Does the Finder 66.22.9.006.0600 have changeover contacts?

No. The .0600 configuration has two normally open contacts (DPST-NO) with an open-contact gap greater than 1.5 mm. It does not provide normally closed switching paths.

What is the difference between Finder 66.22.9.006.0000 and 66.22.9.006.0600?

The 66.22.9.006.0000 is a two-pole changeover relay, whereas the 66.22.9.006.0600 has two normally open contacts with increased contact separation. Both use a nominal 6 V DC coil, but their contact arrangements differ and must be checked before substitution.

What is the contact rating and how is the Finder 66.22.9.006.0600 installed?

The relay has a 30 A nominal contact rating, 250 V AC rated contact voltage and 7,500 VA AC1 switching capacity. It is designed for direct PCB mounting using bifurcated through-hole solder terminals.

Trusted by Industrial Automation Professionals

Finder 66 Series power relays provide high-current electromagnetic switching for industrial machinery, power electronics and electrical control systems. The Finder 66.22.9.006.0600 combines two 30 A normally open contacts, a 6 V DC coil, increased open-contact separation and reinforced insulation in a practical PCB-mounted construction.