Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 66.22.9.006.0000 – 66 Series Power relays.
The Finder 66.22.9.006.0000 is a high-current 30 A, two-pole changeover (DPDT) PCB-mounted power relay designed for industrial automation, power switching and electrical equipment. Part of the Finder 66 Series, this electromagnetic relay combines substantial switching capacity with reinforced coil-to-contact insulation and a compact printed circuit board mounting arrangement.
Featuring a 6 V DC operating coil and two independent changeover contacts, the Finder 66.22.9.006.0000 allows two electrical circuits to be controlled simultaneously from one signal. Its contact system provides normally open and normally closed switching paths, making it suitable for applications requiring high-current switching, circuit changeover or electrical interlocking.
The relay provides a 30 A normally open contact rating, a 250 V AC rated contact voltage and up to 7,500 VA AC1 switching capacity on its normally open contacts. Its reinforced insulation, 6 kV coil-to-contact impulse withstand voltage and PCB solder terminals make it suitable for integration into industrial electronic assemblies, machinery and power control equipment.
The Finder 66.22.9.006.0000 operates through an electromagnetic coil energised by a 6 V DC control supply. When energised, its two changeover contact sets transfer from their normally closed positions to their normally open positions. Removing the coil supply returns the contacts to their normal states, allowing the relay to perform circuit switching, changeover and interlocking functions.
A key characteristic of this relay is the distinction between its normally open and normally closed contact ratings. The normally open contacts are rated at 30 A, while the normally closed contacts are rated at 10 A. This difference must be considered when designing the circuit, particularly where both contact paths are used for switching substantial electrical loads.
The relay's 7,500 VA AC1 switching capacity on normally open contacts supports demanding resistive-load applications. For inductive loads, motors and DC circuits, the relevant utilisation-category ratings must be observed. The relay also provides a 440 V AC maximum switching voltage, subject to the applicable load and insulation requirements.
Reinforced insulation between the coil and contact circuits is an important feature of the Finder 66 Series. With 8 mm creepage and clearance distances and a 6 kV impulse withstand rating, the relay supports electrical separation between low-voltage control electronics and higher-voltage switched circuits when correctly incorporated into the equipment design.
The 66.22 PCB-mounting arrangement uses bifurcated solder terminals for secure installation onto a suitably designed printed circuit board. The board layout, copper track capacity, terminal soldering, thermal management and electrical spacing must all be designed for the intended switching current and operating conditions.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | PCB / pins | |
| Load Voltage | 440 V AC | |
| Mounting Type | PCB | |
| Manufacturer | Finder | |
| Series | 66 Series | |
| Model | 66.22.9.006.0000 | |
| Manufacturer part number | 66.22.9.006.0000 | |
| Product type | Industrial electromagnetic power relay | |
| Contact configuration | DPDT / 2 Form C | |
| Number of poles | 2 | |
| Number of changeover contacts | 2 | |
| Rated normally open contact current | 30 A | |
| Rated normally closed contact current | 10 A | |
| Maximum peak current, normally open contacts | 120 A for 5 ms, subject to contact material | |
| Maximum peak current, normally closed contacts | 20 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 440 V AC | |
| Rated AC1 switching capacity, normally open | 7,500 VA | |
| Rated AC1 switching capacity, normally closed | 2,500 VA | |
| Rated AC15 switching capacity at 230 V AC | 1,200 VA on normally open contacts | |
| Single-phase motor rating at 230 V AC | 1.5 kW on normally open contacts | |
| DC1 breaking capacity at 24 V DC | 25 A on normally open contacts | |
| DC1 breaking capacity at 110 V DC | 0.7 A on normally open contacts | |
| DC1 breaking capacity at 220 V DC | 0.3 A on normally open contacts | |
| Minimum switching load | 1,000 mW | |
| Nominal coil voltage | 6 V DC | |
| Coil supply type | DC | |
| Coil operating voltage range | 4.8–6.6 V DC | |
| Nominal coil resistance | 21 Ω | |
| Nominal coil current | Approximately 283 mA | |
| Nominal DC coil consumption | 1.7 W | |
| Contact material | Silver-cadmium oxide (AgCdO) | |
| Contact arrangement option | Standard changeover contacts | |
| Relay operation | Electromagnetic, monostable | |
| Mechanical endurance | 10 million cycles | |
| Electrical endurance at rated AC1 load | 100,000 cycles | |
| Typical operate time | 8 ms | |
| Typical release time | 15 ms | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact creepage distance | 8 mm | |
| Coil-to-contact clearance distance | 8 mm | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Dielectric strength between open contacts | 1,500 V AC | |
| Operating ambient temperature | −40 to +70 °C | |
| Environmental protection category | RT II | |
| Mounting type | Printed circuit board (PCB) | |
| Connection type | Bifurcated solder terminals | |
| Approximate dimensions | 51.5 × 33.5 × 31 mm | |
| Approximate weight | 85 g | |
| Application category | Industrial power switching and electronic control equipment |
The Finder 66.22.9.006.0000 is a 30 A industrial PCB-mounted power relay used for switching electrical loads in machinery, power equipment, industrial automation and electronic control assemblies.
The relay has a nominal 6 V DC operating coil with a typical operating range of 4.8–6.6 V DC, approximately 21 Ω coil resistance and 1.7 W nominal coil consumption.
The relay has two changeover contacts (DPDT). Each contact set provides both normally open and normally closed switching paths, with different current ratings for the two contact positions.
No. The normally open contacts are rated at 30 A, while the normally closed contacts are rated at 10 A. The appropriate rating must be used for each circuit when selecting loads and designing the equipment.
The relay is designed for direct printed circuit board mounting using bifurcated solder terminals. It is not the Faston flange-mounted version of the Finder 66 Series, and the PCB must be designed for the intended electrical load and required insulation distances.
Finder 66 Series power relays provide dependable high-current electromagnetic switching for industrial equipment, electrical control systems and PCB-mounted power electronics. The Finder 66.22.9.006.0000 combines two changeover contacts, a 6 V DC coil, 30 A normally open contact capability and reinforced coil-to-contact insulation for demanding industrial switching applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.