Finder 62.82.8.380.0300 - 62 Series Power relays

Finder 62.82.8.380.0300 – 62 Series Power relays

Finder 62.82.8.380.0300 – 62 Series Power relays.

SKU: 62.82.8.380.0300Alt SKU: 628283800300MPN: 62.82.8.380.0300
This product has been discontinued A direct replacement is available below.
Finder 62.82.8.380.4300 - 62 Series Power relays Replacement product Finder 62.82.8.380.4300 - 62 Series Power relays SKU: 62.82.8.380.4300 View

Why Choose the Finder 62.82.8.380.0300 Power Relay?

The Finder 62.82.8.380.0300 is an industrial electromagnetic power relay from the Finder 62 Series, featuring a 380 V AC coil and two normally open contacts (2 NO / DPST-NO). Designed for electrical control and power switching applications, it provides a practical means of operating two independent load circuits from a single control signal.

The relay belongs to the 62.82-0300 configuration, which features normally open contacts with a contact gap of at least 3 mm. This arrangement is particularly useful where a defined contact separation is required when the relay is de-energised. The relay's 16 A rated contact current makes it suitable for appropriately rated industrial electrical loads.

Featuring Faston 250 quick-connect terminals and a rear flange mounting arrangement, the Finder 62.82.8.380.0300 is suited to industrial equipment, electrical panels and machinery control systems. Its two-pole normally open configuration makes it especially relevant for applications requiring simultaneous switching of two circuits.

Key Advantages

  • 380 V AC nominal coil for compatible industrial AC control systems.
  • Two normally open contacts enable simultaneous switching of two independent circuits.
  • 16 A rated contact current supports suitable power switching applications.
  • Contact gap of at least 3 mm provides defined separation between open contacts.
  • Faston 250 terminals allow convenient quick-connect wiring.
  • Rear flange mounting supports secure installation in equipment and electrical assemblies.
  • Monostable electromagnetic operation returns the contacts to their open state when the coil is de-energised.
  • Two-pole switching reduces the need for separate relays when two circuits must operate together.
  • Suitable for industrial automation, machinery control and auxiliary power circuits.
  • Part of the established Finder 62 Series industrial power relay range.

Key Features

  • Finder 62 Series industrial power relay.
  • 62.82-0300 configuration with two normally open contacts.
  • 380 V AC nominal coil voltage.
  • AC coil operation for 50/60 Hz control supplies.
  • 16 A rated contact current.
  • 2 NO / DPST-NO contact arrangement.
  • Contact gap: ≥3 mm.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • Faston 250 terminals measuring 6.3 × 0.8 mm.
  • Rear flange mounting for equipment installation.
  • Electromagnetic, non-latching operation.
  • Two independent normally open contact sets.

Two-Pole Normally Open Switching with Enhanced Contact Separation

The Finder 62.82.8.380.0300 operates using an electromagnetic coil that controls two normally open contact sets. When the 380 V AC coil is energised, the relay closes both contacts, allowing current to flow through the connected load circuits. When the coil is de-energised, the return mechanism opens both contacts.

Unlike a changeover relay, the 62.82-0300 configuration provides two normally open contacts rather than normally open and normally closed contact pairs. Its minimum 3 mm contact gap is a distinguishing feature of this contact arrangement. This contact separation does not, by itself, establish suitability for safety isolation or emergency-stop functions.

The Faston 250 connection system enables suitable quick-connect terminals to be fitted to the relay, while its rear flange arrangement supports secure mounting within industrial equipment. For replacement applications, the coil voltage, contact configuration, terminal arrangement and switching ratings should all be matched to the existing installation.

Typical Applications

  • Industrial automation and machine control systems.
  • Electrical control panels and switchgear assemblies.
  • 380 V AC control circuits.
  • Two-pole normally open load switching.
  • Industrial heating and auxiliary equipment control.
  • Machinery power and control interfaces.
  • Electrical interlocking and equipment sequencing.
  • Industrial signalling and control equipment.
  • Maintenance and replacement of compatible industrial relay installations.
  • OEM machinery and industrial electrical assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 16 A
Load Voltage 400 V AC
Manufacturer Finder
Series 62 Series
Model 62.82.8.380.0300
Product type Electromagnetic power relay
Relay configuration DPST-NO / 2 NO
Number of poles 2
Number of normally open contacts 2
Contact type Normally open
Minimum open contact gap 3 mm
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated switching capacity (AC1) 4000 VA
Nominal coil voltage 380 V AC
Coil supply type AC
Coil frequency 50/60 Hz
Operating principle Electromagnetic, monostable
Mounting arrangement Rear flange mounting
Terminal type Faston 250 quick-connect
Terminal dimensions 6.3 × 0.8 mm
Application Industrial electrical control and power switching

Frequently Asked Questions

What is the Finder 62.82.8.380.0300 used for?

The Finder 62.82.8.380.0300 is an electromagnetic power relay designed to switch two normally open electrical circuits in industrial automation, machinery control and auxiliary power applications.

What coil voltage does the Finder 62.82.8.380.0300 require?

The model is identified by a 380 V AC nominal coil voltage. The control supply must match the coil requirements of the exact relay version.

How many contacts does this relay have?

The relay has two normally open contacts (2 NO), also described as a DPST-NO configuration. Both contacts close when the coil is energised and open when it is de-energised.

Is the Finder 62.82.8.380.0300 a changeover relay?

No. The .0300 contact configuration uses two normally open contacts rather than two changeover contacts. This distinction is important when selecting a replacement relay.

What is the contact current rating?

The relay has a 16 A rated contact current. The allowable switching current depends on the load voltage, load characteristics and the manufacturer's applicable ratings.

What is the contact gap of the Finder 62.82.8.380.0300?

The normally open contacts have a specified separation of at least 3 mm when open. This is a feature of the Finder 62.82-0300 contact configuration.

What terminals does the Finder 62.82.8.380.0300 use?

The relay uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm, allowing connection using appropriately sized mating terminals.

How is the Finder 62.82.8.380.0300 mounted?

The Finder 62.82 relay type features a rear flange mounting arrangement for installation in suitable electrical equipment and industrial control assemblies.

Can this relay operate from a 380 V DC supply?

No. The Finder 62.82.8.380.0300 is identified as an AC-coil relay. A DC supply should not be substituted for the specified AC coil supply.

Can the Finder 62.82.8.380.0300 switch DC loads?

It may switch suitable DC loads only within the manufacturer's specified DC contact ratings. The 16 A AC rating must not automatically be applied to DC switching applications.

Trusted by Industrial Automation and Electrical Control Professionals

Finder 62 Series power relays are used in industrial electrical control and automation applications. The Finder 62.82.8.380.0300 combines a 380 V AC coil, two 16 A normally open contacts with a minimum 3 mm contact gap, Faston 250 terminals and rear flange mounting for suitable industrial switching installations.