Finder 62.33.9.250.4040 - 62 Series Power relays

Finder 62.33.9.250.4040 – 62 Series Power relays

Finder 62.33.9.250.4040 – 62 Series Power relays.

SKU: 62.33.9.250.4040Alt SKU: 623392504040MPN: 62.33.9.250.4040
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 62.33.9.250.4040 Industrial Power Relay?

The Finder 62.33.9.250.4040 is a heavy-duty 16 A industrial electromechanical power relay designed for switching electrical loads in industrial automation, machinery and control panel applications. Part of the established Finder 62 Series, this model combines a 250 V DC coil with three changeover contacts to provide versatile multi-circuit switching.

Featuring a 3 CO (3PDT) contact configuration, the relay enables three independent circuits to be controlled simultaneously. The 62.33 contact system provides a 16 A rated current, 250 V AC rated contact voltage and 400 V AC maximum switching voltage, making it suitable for appropriately rated industrial loads.

The 4040 configuration incorporates silver tin oxide (AgSnO2) contacts, a mechanical operation indicator and a lockable test button. Its plug-in construction is designed for compatible Finder 92 Series sockets, supporting straightforward installation, testing and maintenance in industrial electrical equipment.

Key Advantages

  • 16 A industrial switching: Designed for reliable control of compatible electrical loads.
  • 250 V DC coil: Suitable for control systems using this specific DC supply voltage.
  • Three changeover contacts: Enables simultaneous switching of three independent circuits.
  • Silver tin oxide contacts: AgSnO2 contact material provides dependable power-switching performance.
  • Mechanical indicator: Allows convenient visual inspection of relay operation.
  • Lockable test button: Supports manual testing during commissioning and maintenance.
  • Plug-in installation: Enables convenient replacement without rewiring a compatible socket.
  • High electrical insulation: The 62 Series provides reinforced insulation between the coil and contacts.
  • Industrial temperature capability: Designed for demanding control environments.
  • Flexible socket mounting: Suitable for control panels using appropriate Finder 92 Series accessories.

Key Features

  • Finder 62 Series industrial power relay.
  • 62.33 three-pole changeover configuration.
  • 250 V DC nominal coil voltage.
  • 3 CO (3PDT) contacts.
  • 16 A rated contact current.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • 4,000 VA AC1 rated switching capacity per contact.
  • 30 A maximum peak contact current for the standard 62.33 contact system.
  • Silver tin oxide (AgSnO2) contact material.
  • Monostable, non-latching relay operation.
  • Mechanical operation indicator.
  • Lockable manual test button.
  • Plug-in terminals with Faston 187 connection dimensions.
  • Compatible with appropriately selected Finder 92 Series relay sockets.
  • Reinforced coil-to-contact insulation.
  • Suitable for industrial automation and power-control applications.

Reliable Three-Pole Switching for Industrial Automation

The Finder 62.33.9.250.4040 provides a practical solution for controlling three independent electrical circuits from a single DC control signal. When the 250 V DC coil is energised, the three changeover contacts transfer from their normally closed positions to their normally open positions, enabling coordinated switching of connected equipment.

The Finder 62.33 relay family is designed for applications requiring high-current contacts, reliable electrical isolation and flexible multi-pole switching. Its 16 A contact rating and 4,000 VA AC1 switching capacity make it suitable for appropriately rated resistive loads, while motor and inductive applications must be selected according to their specific switching characteristics.

The silver tin oxide contact material, mechanical indicator and lockable test button provide practical advantages in industrial environments. When used with a compatible Finder 92 Series socket, the relay can be inspected and replaced conveniently, helping simplify electrical panel maintenance and servicing.

Typical Applications

  • Industrial electrical control panels.
  • Automation and process control systems.
  • Machinery and production equipment.
  • Control circuits using 250 V DC supplies.
  • Multi-circuit electrical load switching.
  • Industrial heating and ventilation controls.
  • Motor control auxiliary circuits.
  • Electrical distribution and power management systems.
  • OEM industrial equipment and control assemblies.
  • Industrial relay maintenance and replacement.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 16 A
Load Voltage 400 V AC
Mounting Type Plug-in socket
Manufacturer Finder
Series 62 Series
Product code 62.33.9.250.4040
Relay type 62.33
Product category Industrial electromechanical power relay
Nominal coil voltage 250 V DC
Coil type DC
Relay operation Monostable
Contact configuration 3 CO (3PDT)
Number of poles 3
Rated contact current 16 A
Maximum peak contact current 30 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated AC1 switching capacity 4,000 VA per contact
Rated AC15 switching capacity at 230 V AC 750 VA
Single-phase motor rating at 230 V AC 0.8 kW
Contact material Silver tin oxide (AgSnO2)
Minimum switching load 1,000 mW
Coil-to-contact impulse withstand voltage 6 kV
Coil-to-contact insulation Reinforced
Coil-to-contact clearance 6 mm
Coil-to-contact creepage distance 8 mm
Electrical life at rated AC1 load 100,000 operations
Operating temperature range −40 to +70 °C
Mounting Plug-in relay socket
Terminal type Faston 187, 4.8 × 0.5 mm
Compatible socket family Finder 92 Series

Frequently Asked Questions

What is the Finder 62.33.9.250.4040 used for?

The Finder 62.33.9.250.4040 is a three-pole industrial power relay used for switching electrical loads in industrial automation, machinery, control panels and process control systems.

What coil voltage does the Finder 62.33.9.250.4040 require?

The relay is specified with a nominal 250 V DC coil. It is intended for compatible DC control supplies and must not be connected directly to an AC supply.

What is the contact rating of the Finder 62.33.9.250.4040?

The Finder 62.33 contact system has three changeover contacts rated at 16 A and 250 V AC, with a maximum switching voltage of 400 V AC and an AC1 switching capacity of 4,000 VA per contact.

Does the Finder 62.33.9.250.4040 have normally open and normally closed contacts?

Yes. The relay features a 3 CO (3PDT) configuration, providing three sets of common, normally open and normally closed contacts. All three sets change state when the relay coil is energised.

How is the Finder 62.33.9.250.4040 installed and tested?

The relay uses plug-in terminals and is designed for compatible Finder 92 Series relay sockets. Its mechanical indicator and lockable test button support inspection and commissioning, with manual testing performed only under appropriate electrical safety procedures.

Trusted by Industrial Automation and Electrical Control Professionals

Finder 62 Series industrial power relays offer dependable multi-pole switching for automation engineers, electrical panel builders, machinery manufacturers and maintenance professionals, combining robust contact performance, practical testing features and convenient plug-in installation for demanding industrial control applications.