Finder 62.33.9.032.0040 - 62 Series Power relays

Finder 62.33.9.032.0040 – 62 Series Power relays

Finder 62.33.9.032.0040 – 62 Series Power relays.

SKU: 62.33.9.032.0040Alt SKU: 623390320040MPN: 62.33.9.032.0040
This product has been discontinued A direct replacement is available below.
Finder 62.33.9.032.4040 - 62 Series Power relays Replacement product Finder 62.33.9.032.4040 - 62 Series Power relays SKU: 62.33.9.032.4040 View

Why Choose the Finder 62.33.9.032.0040 Industrial Power Relay?

The Finder 62.33.9.032.0040 is a robust 16 A, 32 V DC industrial power relay designed for dependable electrical switching in industrial automation, machinery control and electrical control panels. Part of the Finder Series 62 power relay range, this electromechanical relay combines three changeover contacts with a plug-in mounting arrangement and convenient manual testing features.

Featuring a three-pole double-throw (3PDT, 3 CO) contact configuration, the Finder 62.33.9.032.0040 allows three independent electrical circuits to be switched using a single electromagnetic coil. Its 32 V DC nominal coil voltage makes it suitable for equipment specifically designed around this control voltage, while its 16 A rated contacts at 250 V AC provide substantial switching capacity for industrial electrical loads.

The 0040 variant features a lockable manual test button and mechanical flag indicator, making it particularly useful for equipment commissioning, maintenance and fault-finding. Its plug-in construction is designed for compatible Finder Series 92 relay sockets, allowing straightforward installation and replacement in suitably designed control panels.

Key Advantages

  • 16 A rated contact current provides substantial switching capacity for industrial control and power applications.
  • Three changeover contacts (3PDT, 3 CO) enable simultaneous switching of three independent electrical circuits.
  • 32 V DC nominal coil voltage suits compatible industrial equipment requiring this specific DC control supply.
  • Lockable manual test button supports functional checks during commissioning and maintenance.
  • Mechanical flag indicator provides visual confirmation of the relay's mechanical operating position.
  • Plug-in mounting arrangement simplifies installation, servicing and relay replacement.
  • 4,000 VA AC1 switching capacity supports higher-current resistive switching applications.
  • Silver cadmium oxide (AgCdO) contacts provide a robust contact system for industrial switching duties.
  • Monostable electromagnetic operation returns the contacts to their normal positions when the coil is de-energised, provided the manual test mechanism is not locked.
  • Finder Series 62 construction provides a versatile switching solution for industrial automation and OEM electrical equipment.

Key Features

  • Finder Series 62 industrial power relay.
  • Type 62.33 with three changeover contacts.
  • 32 V DC nominal coil voltage.
  • 3PDT (3 CO, 3 Form C) contact configuration.
  • 16 A rated contact current.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • 4,000 VA rated AC1 switching load.
  • 750 VA rated AC15 switching load at 230 V AC.
  • 30 A maximum peak contact current under specified conditions.
  • Silver cadmium oxide (AgCdO) contact material.
  • Lockable manual test button for functional testing.
  • Mechanical flag indicator for visual contact-position indication.
  • Plug-in terminals for compatible Finder Series 92 sockets.
  • Monostable, non-latching electromagnetic operation.
  • Suitable for electrical control panels, industrial machinery and automation systems.

Dependable Three-Pole Switching for 32 V DC Control Systems

The Finder 62.33.9.032.0040 operates using an electromagnetic coil that actuates three mechanically linked changeover contacts. When the 32 V DC coil is energised, the contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the contacts return to their normal positions during standard operation.

The 3PDT contact configuration makes the relay suitable for applications requiring several electrical switching functions from a single control signal. For example, one contact may operate an auxiliary load, another may control a signalling circuit and the third may provide an electrical interlocking function. The three contact circuits are electrically separate, offering flexibility when designing industrial control equipment.

With a 16 A rated contact current and 4,000 VA AC1 switching capacity, this Finder Series 62 power relay is suitable for substantial resistive switching duties. The permissible switching current may be lower for motors, inductive loads, transformers and other equipment with significant inrush currents. Engineers should assess the actual load characteristics and applicable switching category before selecting the relay.

Lockable Manual Test Button and Mechanical Flag Indicator

The Finder 62.33.9.032.0040 includes a manual test button that allows the relay contacts to be actuated without energising the coil. This provides a convenient method of checking the operation of connected control circuits during commissioning, inspection and fault-finding.

Finder's dual-purpose test mechanism can be used for momentary testing or, after deliberate removal of the retaining feature in accordance with the manufacturer's instructions, locking operation. In its normal configuration, pressing the button operates the contacts and releasing it allows them to return to their previous positions. When configured for locking, the button can be pressed and rotated to maintain the contacts in their actuated positions until manually released.

The integrated mechanical flag indicator provides visual feedback of the relay's mechanical position. This is particularly useful in control panels containing several relays, where maintenance personnel may need to identify which devices are actuated.

Manual operation can switch connected circuits independently of the coil supply. The test mechanism should therefore only be used under appropriate electrical safety procedures, and the button must be returned to its normal position after testing.

Convenient Plug-In Installation with Finder Series 92 Sockets

The Finder 62.33.9.032.0040 uses a plug-in terminal arrangement designed for compatible Finder Series 92 relay sockets. This allows the relay to be installed into suitable electrical control panels without soldering it directly to a printed circuit board.

Plug-in mounting can simplify servicing because the relay may be removed and replaced without disturbing the permanent socket wiring. This is particularly useful for industrial machinery and automation equipment where maintenance access and component replacement are important.

Suitable Series 92 socket and mounting accessory combinations can support DIN rail or panel installation, depending on the selected components. The correct socket must be matched to the Type 62.33 terminal arrangement and the electrical requirements of the installation.

Because this model uses a 32 V DC coil, it must not be treated as interchangeable with otherwise similar 24 V DC or 48 V DC versions without checking the control supply and equipment requirements.

Typical Applications

  • Industrial automation and process control systems.
  • Electrical control equipment using 32 V DC control supplies.
  • Industrial machinery and OEM electrical assemblies.
  • Electrical control panels and relay interface assemblies.
  • Higher-current auxiliary power switching.
  • Electrical interlocking and multi-circuit control.
  • Equipment status signalling and control circuit sequencing.
  • Building automation and equipment management systems.
  • Motor control auxiliary circuits, subject to appropriate load ratings.
  • Industrial heating and ventilation control equipment.
  • Commissioning and maintenance applications requiring manual relay testing.
  • Serviceable plug-in relay installations.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type PCB / pins
Load Voltage 400 V AC
Mounting Type Plug-in socket
Switching Current (A) 16 A
Manufacturer Finder
Series Series 62 Power Relays
Type 62.33
Model 62.33.9.032.0040
Product type Electromechanical plug-in industrial power relay
Contact configuration 3 CO (3PDT, 3 Form C)
Number of poles 3
Rated contact current 16 A
Maximum peak contact current 30 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated AC1 switching load 4,000 VA
Rated AC15 switching load at 230 V AC 750 VA
Single-phase motor rating at 230 V AC 0.8 kW
DC1 switching current at 30 V DC 16 A
DC1 switching current at 110 V DC 0.6 A
DC1 switching current at 220 V DC 0.4 A
Minimum switching load 1,000 mW
Rated coil voltage 32 V DC
Coil supply type DC
Nominal coil consumption Approximately 1.3 W for the standard DC coil configuration
Contact material Silver cadmium oxide (AgCdO)
Relay operation Monostable, non-latching
Manual test facility Lockable test button
Status indication Mechanical flag indicator
Mounting type Plug-in socket mounting
Terminal type Plug-in pins
Compatible socket family Finder Series 92, suitable Type 62.33 versions
Operating temperature −40 to +70 °C
Electrical life at rated AC1 load Approximately 100,000 cycles
Typical applications Industrial automation, machinery control, electrical interlocking and multi-circuit switching

Frequently Asked Questions

What is the Finder 62.33.9.032.0040 used for?

The Finder 62.33.9.032.0040 is a plug-in industrial power relay designed for switching electrical circuits in automation systems, machinery and control panels. Its three changeover contacts allow three independent circuits to be operated using one electromagnetic coil.

What coil voltage does the Finder 62.33.9.032.0040 require?

The relay is specified with a nominal 32 V DC coil. It should be operated from a compatible DC control supply within the manufacturer's specified operating range. It is not a direct coil-voltage substitute for a 24 V DC relay.

What is the contact rating of the Finder 62.33.9.032.0040?

The relay has three 16 A changeover contacts with a rated contact voltage of 250 V AC, a maximum switching voltage of 400 V AC and a rated AC1 resistive switching capacity of 4,000 VA. Lower limits may apply to inductive and high-inrush loads.

Does the Finder 62.33.9.032.0040 have a lockable test button?

Yes. The 0040 variant includes a lockable manual test button and mechanical flag indicator. The button supports manual contact operation during commissioning and maintenance. Locking operation requires deliberate modification of the retaining feature in accordance with Finder's instructions.

Which socket is compatible with the Finder 62.33.9.032.0040?

The relay is designed for compatible Finder Series 92 relay sockets matched to the Type 62.33 terminal arrangement. Suitable socket and accessory combinations can provide convenient installation in industrial control panels. The exact socket should be selected according to the manufacturer's compatibility information and the installation's electrical requirements.

Trusted Finder Power Relay Technology for Industrial Automation

The Finder 62.33.9.032.0040 combines a 32 V DC coil, three 16 A changeover contacts, convenient plug-in mounting, a lockable manual test button and mechanical flag indication in a robust industrial power relay. Designed for multi-circuit control and higher-current switching, it offers a practical solution for automation engineers, electrical panel builders and OEM equipment manufacturers requiring reliable switching and maintenance-friendly installation.