Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 62.32.9.080.4300 is a 16 A two-pole normally open electromagnetic power relay with an 80 V DC coil designation, silver tin oxide contacts, at least 3 mm contact separation and plug-in mounting for industrial electrical switching.
The Finder 62.32.9.080.4300 is a 16 A electromagnetic power relay with an 80 V DC coil designation, designed for electrical switching in industrial automation, machinery control and electrical control systems. Part of the established Finder 62 Series, this relay combines two-pole switching capability with a practical plug-in design for industrial installations.
Featuring two normally open contacts (2 NO / DPST-NO), the Finder 62.32.9.080.4300 enables two separate electrical circuits to be switched simultaneously using a single DC operating coil. Its silver tin oxide (AgSnO2) contact material offers resistance to contact welding, while the contact opening distance of at least 3 mm provides increased separation between the contacts when the relay is de-energised.
With a 16 A nominal contact current rating, 250 V AC rated switching voltage and plug-in mounting arrangement, this Finder relay is suitable for appropriately rated industrial electrical loads. The 80 V DC coil designation identifies the specified coil variant; because this is an uncommon voltage within the standard published 62 Series coil range, the exact operating limits should be confirmed against the product-specific technical documentation before installation.
The Finder 62.32.9.080.4300 is designed to control electrical loads through a separate DC operating circuit. When the relay coil is energised at its specified operating voltage, the electromagnetic mechanism closes both normally open contacts, allowing current to flow through the connected load circuits. When the coil is de-energised, the contacts return to their open positions, interrupting both circuits.
The Finder 62 Series is developed for electrical installations where dependable switching, electrical separation and straightforward maintenance are important. The 62.32 plug-in construction allows convenient relay replacement, while the two normally open contacts and increased contact gap provide a practical switching arrangement for industrial equipment. The exact 80 V DC coil characteristics should be checked when selecting the control supply or replacing an existing relay.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Mounting Type | Plug-in socket | |
| Manufacturer | Finder | |
| Series | 62 Series Power Relays | |
| Model | 62.32.9.080.4300 | |
| Product type | Electromagnetic power relay | |
| Relay family | 62.32 | |
| Coil voltage designation | 80 V DC | |
| Coil supply type | DC | |
| Number of poles | 2 | |
| Contact configuration | 2 normally open (2 NO / DPST-NO) | |
| Rated contact current | 16 A | |
| Rated switching voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC for the standard contact family | |
| Rated resistive-load switching capacity (AC-1) | 4,000 VA | |
| Contact gap | ≥3 mm | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Operating principle | Electromagnetic switching | |
| Relay operation | Monostable / non-latching | |
| Mounting type | Plug-in / socket mounting | |
| Terminal type | Faston 187 quick-connect terminals | |
| Terminal dimensions | 4.8 × 0.5 mm | |
| Compatible socket family | Finder 92 Series | |
| Coil-to-contact insulation | Reinforced insulation | |
| Coil-to-contact rated impulse withstand voltage | 6 kV for the standard 62 Series design | |
| Environmental protection category | RT I for the standard relay family | |
| Application | Industrial automation and electrical switching |
The Finder 62.32.9.080.4300 is an electromagnetic power relay intended for switching electrical circuits in industrial automation, machinery control and electrical control panels. Its two normally open contacts allow two separate circuits to be controlled by a single DC operating coil.
The part number specifies an 80 V DC coil designation. As 80 V DC is not among the commonly listed standard Finder 62 Series coil voltages, the precise operating voltage range and coil electrical characteristics should be confirmed against the documentation for this exact variant.
The Finder 62.32 relay family has a 16 A nominal contact current rating at 250 V AC for specified resistive-load conditions. The permissible switching current depends on the connected load, operating voltage and electrical switching conditions.
The 4300 contact configuration features two normally open contacts (2 NO / DPST-NO), rather than changeover contacts. Both contacts close when the coil is energised and open when the coil is de-energised. This arrangement provides a contact opening distance of at least 3 mm.
The relay uses a plug-in mounting arrangement with Faston 187 quick-connect terminals measuring 4.8 × 0.5 mm. It is designed for installation with a compatible Finder 92 Series relay socket, supporting convenient servicing and replacement in electrical control equipment.
Finder 62 Series power relays are designed for industrial automation, electrical control and machinery applications where dependable switching and practical maintenance are essential. The Finder 62.32.9.080.4300 combines a DC operating coil designation, 16 A contact rating, two normally open contacts and increased contact separation in a practical plug-in format for industrial electrical control applications.