Finder 62.32.9.036.0006 - 62 Series Power relays

Finder 62.32.9.036.0006 – 62 Series Power relays

Finder 62.32.9.036.0006 – 62 Series Power relays.

SKU: 62.32.9.036.0006Alt SKU: 623290360006MPN: 62.32.9.036.0006
This product has been discontinued A direct replacement is available below.
Finder 62.32.9.036.4006 - 62 Series Power relays Replacement product Finder 62.32.9.036.4006 - 62 Series Power relays SKU: 62.32.9.036.4006 View

Why Choose the Finder 62.32.9.036.0006 Industrial Power Relay?

The Finder 62.32.9.036.0006 is a high-performance two-pole changeover (DPDT) industrial power relay designed for reliable switching in industrial automation, electrical control panels and machinery applications. As part of the established Finder 62 Series power relay range, it combines a substantial contact current rating with a compact plug-in design and robust electromagnetic switching technology.

Featuring a 36 V DC operating coil and two changeover contacts rated at 16 A, the Finder 62.32.9.036.0006 enables two independent electrical circuits to be controlled through a single electromagnetic operating mechanism. Its silver-cadmium oxide (AgCdO) contact material provides dependable switching performance, while the .0006 rear-flange mounting configuration offers additional installation flexibility.

The relay provides a 250 V AC rated contact voltage, a maximum switching voltage of 400 V AC and a nominal AC1 switching capacity of 4,000 VA. Its plug-in/Faston 187 terminal arrangement supports installation in compatible Finder 92 Series relay sockets or suitable quick-connect wiring arrangements, making it a practical solution for industrial machinery, auxiliary power switching and electrical automation systems.

Key Advantages

  • Reliable 16 A industrial power relay for electrical control and automation applications.
  • Two changeover contacts (DPDT) enable switching of two independent electrical circuits.
  • 36 V DC operating coil suitable for compatible industrial DC control supplies.
  • 250 V AC rated contact voltage for general-purpose electrical switching.
  • 4,000 VA AC1 switching capacity for resistive AC loads.
  • AgCdO contact material supports dependable switching under suitable load conditions.
  • Rear-flange mounting configuration provides additional mechanical installation options.
  • Plug-in/Faston terminal construction simplifies installation and replacement.
  • Compatible with appropriately selected Finder 92 Series relay sockets.
  • Suitable for industrial machinery, electrical distribution and auxiliary switching systems.
  • Reinforced insulation between the coil and contacts supports electrical separation in control equipment.

Key Features

  • Finder 62 Series industrial power relay.
  • DPDT (2 Form C) contact arrangement.
  • Two independent changeover contacts.
  • 16 A nominal contact current.
  • 36 V DC nominal coil voltage.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • 4,000 VA rated AC1 switching capacity.
  • 750 VA AC15 switching capacity at 230 V AC.
  • Silver-cadmium oxide (AgCdO) contact material.
  • Rear-flange mounting option identified by the .0006 suffix.
  • Electromagnetic, monostable switching operation.
  • Plug-in/Faston 187 terminal arrangement.
  • Compatible with suitable Finder 92 Series sockets.
  • 11 ms typical operate time.
  • 4 ms typical release time.
  • Designed for industrial automation, power switching and electrical control applications.

Reliable 36 V DC Power Relay Switching with Rear-Flange Mounting

The Finder 62.32.9.036.0006 operates by applying a 36 V DC control voltage to its electromagnetic coil. When energised, the relay transfers its two changeover contacts from their normal positions to their operated positions. When the coil is de-energised, the contacts return to their normal states.

Its DPDT contact arrangement provides two electrically independent changeover contact sets controlled by one coil. This configuration is useful in machinery sequencing, auxiliary switching, electrical interlocking and control circuits where two separate switching functions must operate simultaneously.

The relay's 16 A nominal contact rating and 4,000 VA AC1 switching capacity make it suitable for higher-current switching applications than many conventional miniature control relays. For inductive loads, motors and DC circuits, the relevant load-specific switching ratings must be observed rather than relying solely on the nominal contact current.

The .0006 rear-flange configuration provides an alternative mounting arrangement for equipment designs requiring mechanical fixing. The relay also uses a plug-in/Faston 187 terminal system, allowing integration with compatible Finder 92 Series sockets or suitable quick-connect wiring.

Its AgCdO contacts, reinforced coil-to-contact insulation and established Finder 62 Series construction make the 62.32.9.036.0006 a practical switching component for industrial control panels, machinery and electrical equipment requiring dependable electromagnetic relay operation.

Typical Applications

  • Industrial automation and machinery control panels.
  • 36 V DC electrical control circuits.
  • Electrical power switching and auxiliary control systems.
  • Industrial heating and process control equipment.
  • Motor starter auxiliary switching and control circuits.
  • Electrical interlocking and machinery sequencing.
  • Industrial pumps, fans and equipment control interfaces.
  • Electrical distribution and switching equipment.
  • Manufacturing and production machinery.
  • Equipment requiring rear-flange relay mounting.
  • Maintenance and replacement of compatible Finder 62 Series power relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Load Voltage 400 V AC
Switching Current (A) 16 A
Manufacturer Finder
Series 62 Series
Model 62.32.9.036.0006
Manufacturer part number 62.32.9.036.0006
Product type Industrial electromagnetic power relay
Contact configuration DPDT / 2 Form C
Number of poles 2
Number of changeover contacts 2
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated switching capacity (AC1) 4,000 VA
Rated switching capacity (AC15 at 230 V AC) 750 VA
Single-phase motor rating at 230 V AC 0.8 kW
DC1 breaking capacity at 24 V DC 16 A
DC1 breaking capacity at 110 V DC 0.6 A
DC1 breaking capacity at 220 V DC 0.4 A
Minimum switching load 1,000 mW
Nominal coil voltage 36 V DC
Coil supply type DC
Minimum operate voltage 28.8 V DC
Maximum nominal operating voltage 39.6 V DC
Maximum release voltage 7.2 V DC
Nominal DC coil consumption 1.3 W
Contact material Silver-cadmium oxide (AgCdO)
Contact material option 0 — AgCdO
Special version 6 — Rear-flange mounting
Relay operation Electromagnetic, monostable
Coil type Non-latching
Mechanical endurance (DC coil) 30 million cycles
Electrical endurance at rated AC1 load 100,000 cycles
Typical operate time 11 ms
Typical release time 4 ms
Impulse withstand voltage between coil and contacts 6 kV
Dielectric strength between open contacts 1,500 V AC
Operating ambient temperature −40 to +70 °C
Environmental protection category RT I
Connection type Plug-in / Faston 187
Faston terminal dimensions 4.8 × 0.5 mm
Mounting arrangement Rear flange or compatible relay socket
Compatible socket family Finder 92 Series
Application category Industrial automation and electrical power switching

Frequently Asked Questions

What is the Finder 62.32.9.036.0006 used for?

The Finder 62.32.9.036.0006 is a two-pole industrial electromagnetic power relay used for switching electrical circuits in industrial automation, machinery control, auxiliary power systems and electrical equipment.

What coil voltage does the Finder 62.32.9.036.0006 require?

The relay operates with a nominal 36 V DC coil supply. Its minimum operate voltage is 28.8 V DC, and the standard DC coil operating range extends to approximately 39.6 V DC.

How many contacts does the Finder 62.32.9.036.0006 have?

The relay features two changeover contacts (DPDT), allowing two independent electrical circuits to be switched simultaneously through a single electromagnetic operating coil.

What does the .0006 suffix mean on this Finder relay?

The .0006 suffix identifies the standard AgCdO contact configuration with a rear-flange mounting arrangement. This provides an additional mechanical installation option for suitable industrial equipment.

What is the contact rating and how is the relay installed?

The Finder 62.32.9.036.0006 has a 16 A nominal contact rating and a 250 V AC rated contact voltage. It uses plug-in/Faston 187 terminals and can be installed using its rear-flange arrangement or a compatible Finder 92 Series relay socket.

Trusted by Industrial Automation Professionals

Finder 62 Series power relays provide dependable electromagnetic switching for industrial automation, machinery and electrical power control applications. The Finder 62.32.9.036.0006 combines two 16 A changeover contacts, a 36 V DC operating coil, AgCdO contact technology and rear-flange mounting flexibility to support reliable switching in industrial electrical systems.