Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 50.16.9.012.5510 is an 8 A six-pole PCB safety relay featuring a 12 V DC coil, five normally open contacts, one normally closed contact and Type A forcibly guided contact technology in accordance with EN 61810-3 for safety-related industrial control applications.
£24.19
The Finder 50.16.9.012.5510 is a six-pole electromechanical safety relay from the Finder 50 Series, designed for industrial safety-related control circuits requiring Type A forcibly guided contacts. Featuring a 12 V DC operating coil, five normally open contacts (5 NO) and one normally closed contact (1 NC), this relay combines multiple switching outputs with a mechanically linked feedback contact.
Designed in accordance with EN 61810-3 for forcibly guided contact operation, the Finder 50.16.9.012.5510 is suitable for integration into appropriately engineered safety monitoring systems, machinery controls and industrial automation equipment. Its 8 A rated contact current, 250 V AC rated contact voltage and silver tin oxide (AgSnO₂) contacts provide dependable switching for suitable electrical loads.
The relay features PCB through-hole mounting, a 5 mm terminal pitch and compact dimensions of 55 × 16.5 × 16.5 mm. Its RT III wash-tight construction, low-power DC coil and mechanically linked contact system make it a practical component for safety relay modules, industrial electronic assemblies and control equipment.
The defining characteristic of the Finder 50.16.9.012.5510 is its Type A forcibly guided contact system. The five normally open contacts and one normally closed contact are mechanically linked to provide predictable contact relationships under the conditions defined by EN 61810-3.
In an appropriately designed monitoring circuit, the normally closed contact can provide feedback about the state of the relay's switching mechanism. If a normally open contact becomes welded closed, the forcibly guided arrangement prevents the associated normally closed contact from returning to its normal closed state, allowing suitable monitoring electronics to identify the fault.
The 5 NO + 1 NC arrangement is particularly useful where multiple switched outputs and one feedback contact are required within a single safety-related control assembly.
Safety design consideration: The relay is a component for integration into a safety system and does not independently establish a particular Safety Integrity Level (SIL) or Performance Level (PL). The complete safety function must be designed and validated according to the relevant application standards.
The Finder 50.16.9.012.5510 uses a 12 V DC electromagnetic coil to operate all six contacts. When the coil is energised, the five normally open contacts close and the normally closed contact opens. When the coil is de-energised, the contacts return to their normal positions, provided the relay is functioning correctly.
Its 180 Ω coil resistance corresponds to approximately 66.6 mA nominal current and 0.8 W power consumption. These characteristics allow the relay to be driven by a suitably rated DC control circuit.
The AgSnO₂ contact material is suited to electromechanical switching applications. With a rated resistive contact capacity of 8 A at 250 V AC and 8 A at 24 V DC, the relay provides flexible switching performance when operated within its specified electrical limits.
The Finder 50.16.9.012.5510 is designed for direct PCB through-hole mounting. Its 5 mm terminal pitch and compact 55 × 16.5 × 16.5 mm housing make it suitable for safety monitoring boards, industrial electronic assemblies and multi-output control modules.
The RT III wash-tight construction supports integration into PCB manufacturing processes involving suitable cleaning operations. Its enclosed construction helps protect the relay's internal contact mechanism during specified assembly procedures.
For reliable performance, the final PCB design should account for contact loading, conductor sizing, coil drive requirements, electrical separation and the relevant safety architecture.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Auxiliary Contacts | 1 NC | |
| Mounting Type | PCB | |
| Switching Current (A) | 8 A | |
| Manufacturer | Finder | |
| Series | 50 Series | |
| Manufacturer part number | 50.16.9.012.5510 | |
| Relay type | 50.16 | |
| Product category | Forcibly guided safety relays | |
| Relay technology | Electromechanical | |
| Relay operation | Monostable / non-latching | |
| Contact guidance | Type A, forcibly guided | |
| Contact guidance standard | EN 61810-3 | |
| Total number of contacts | 6 | |
| Normally open contacts | 5 | |
| Normally closed contacts | 1 | |
| Contact configuration | 5 NO + 1 NC | |
| Rated contact current | 8 A | |
| Maximum peak contact current | 15 A | |
| Rated contact voltage | 250 V AC | |
| Maximum AC switching voltage | 400 V AC | |
| Maximum DC switching voltage | 220 V DC | |
| Resistive AC contact rating | 8 A at 250 V AC | |
| Rated AC-1 switching capacity | 2,000 VA | |
| Resistive DC contact rating | 8 A at 24 V DC | |
| Contact material | Silver tin oxide (AgSnO₂) | |
| Nominal coil voltage | 12 V DC | |
| Coil supply type | DC | |
| Nominal coil resistance | 180 Ω | |
| Nominal coil current | Approximately 66.6 mA | |
| Nominal coil consumption | 0.8 W | |
| Mounting type | PCB through-hole | |
| Terminal pitch | 5 mm | |
| Protection category | RT III, wash-tight | |
| Dimensions (L × W × H) | 55 × 16.5 × 16.5 mm | |
| Operating temperature | −40 to +70 °C | |
| EAN / GTIN | 8012823416106 | |
| Application | Safety-related switching, contact-state monitoring and industrial automation |
The Finder 50.16.9.012.5510 is a six-pole safety relay with Type A forcibly guided contacts, designed for use in industrial safety-related control electronics, machinery monitoring circuits, automation equipment and PCB-based switching assemblies.
The relay operates with a 12 V DC nominal coil. It has a nominal resistance of 180 Ω, approximately 66.6 mA coil current and 0.8 W nominal coil consumption.
The relay features six forcibly guided contacts, comprising five normally open contacts (5 NO) and one normally closed contact (1 NC). This arrangement supports multiple switching outputs and contact-state feedback.
The relay has an 8 A rated contact current, with a resistive switching rating of 8 A at 250 V AC and 8 A at 24 V DC. Its maximum peak contact current is 15 A, subject to the specified operating conditions.
The Finder 50.16.9.012.5510 is designed for PCB through-hole mounting. It features a 5 mm terminal pitch, dimensions of 55 × 16.5 × 16.5 mm and RT III wash-tight construction for integration into industrial electronic assemblies.
Finder 50 Series safety relays combine forcibly guided contact technology, compact PCB construction and reliable electromechanical switching. Their multi-contact arrangements make them suitable for engineers and equipment manufacturers developing appropriately designed safety-related monitoring and control systems.
We use cookies