Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 50.16.9.012.5420 is an 8 A six-pole PCB safety relay with a 12 V DC coil, four normally open contacts, two normally closed contacts and Type A forcibly guided contact technology compliant with EN 61810-3 for safety-related industrial control applications.
£23.83
The Finder 50.16.9.012.5420 is a six-pole electromechanical safety relay from the Finder 50 Series, specifically designed for applications requiring forcibly guided contacts. Featuring a 12 V DC operating coil, four normally open (4 NO) contacts and two normally closed (2 NC) contacts, this relay provides reliable switching and contact-state monitoring for safety-related electrical control systems.
Manufactured with Type A forcibly guided contacts in accordance with EN 61810-3, the Finder 50.16.9.012.5420 provides a mechanically linked contact arrangement that helps support fault detection in appropriately designed safety circuits. Its 8 A rated contact current, 250 V AC rated contact voltage and silver tin oxide contacts with gold plating (AgSnO₂ + Au) make it suitable for a range of industrial control and safety-monitoring applications.
The relay features PCB through-hole mounting, a 5 mm terminal pitch and a compact housing measuring approximately 55 × 16.5 × 16.5 mm. Its RT III wash-tight protection category, reinforced coil-to-contact insulation and six independent contact circuits make it particularly suitable for safety relay assemblies, machinery control electronics and industrial automation equipment.
The defining feature of the Finder 50.16.9.012.5420 is its Type A forcibly guided contact arrangement. Unlike conventional relays, the normally open and normally closed contacts are mechanically linked so that they cannot simultaneously occupy incompatible closed states under the fault conditions addressed by the relevant standard.
This construction allows suitably designed monitoring circuits to detect certain contact faults, including a welded contact. The relay's four normally open contacts can be used for switching functions, while the two normally closed contacts can provide feedback to the associated monitoring electronics.
All six contacts belong to the forcibly guided arrangement, making the relay useful in applications where contact-state monitoring is an important part of the safety architecture.
Important: A forcibly guided relay is a component used within a safety system; it does not independently provide a complete safety function or establish a particular Performance Level (PL) or Safety Integrity Level (SIL). The complete circuit must be designed, evaluated and validated for the intended safety requirements.
The Finder 50.16.9.012.5420 operates using a 12 V DC electromagnetic coil. When energised, its four normally open contacts close and its two normally closed contacts open. When the coil is de-energised, the contacts return to their normal positions, provided the relay is operating correctly.
The coil has a nominal resistance of 180 Ω, corresponding to approximately 66.7 mA nominal current and 0.8 W power consumption. This allows the relay to be driven by an appropriately rated DC control circuit.
The AgSnO₂ + Au contact system combines silver tin oxide switching characteristics with gold plating. The relay also provides reinforced insulation between the coil and contact circuits, including a 6 kV impulse withstand rating.
The Finder 50.16.9.012.5420 is designed for direct PCB through-hole mounting, with a 5 mm terminal pitch and an approximate body size of 55 × 16.5 × 16.5 mm. This configuration allows six contact circuits to be incorporated into a compact electronic assembly.
Its RT III wash-tight construction provides protection suitable for specified PCB washing processes. The relay is particularly useful for manufacturers developing safety interface boards, industrial monitoring equipment and machinery control electronics.
PCB track sizing, contact loading, coil drive capability, electrical clearances and applicable safety requirements should be verified as part of the final equipment design.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Auxiliary Contacts | 2 NC | |
| Mounting Type | PCB | |
| Switching Current (A) | 8 A | |
| Manufacturer | Finder | |
| Series | 50 Series | |
| Manufacturer part number | 50.16.9.012.5420 | |
| Relay type | 50.16 | |
| Product category | Forcibly guided safety relays | |
| Relay technology | Electromechanical | |
| Relay operation | Monostable / non-latching | |
| Contact guidance | Type A, forcibly guided | |
| Contact guidance standard | EN 61810-3 | |
| Total number of contacts | 6 | |
| Normally open contacts | 4 | |
| Normally closed contacts | 2 | |
| Contact configuration | 4 NO + 2 NC | |
| Rated contact current | 8 A | |
| Maximum peak contact current | 15 A | |
| Rated contact voltage | 250 V AC | |
| Maximum AC switching voltage | 400 V AC | |
| Maximum DC switching voltage | 220 V DC | |
| Rated AC-1 switching capacity | 2,000 VA | |
| Rated DC resistive load | 8 A at 24 V DC | |
| Contact material | Silver tin oxide with gold plating (AgSnO₂ + Au) | |
| Nominal coil voltage | 12 V DC | |
| Coil supply type | DC | |
| Nominal coil resistance | 180 Ω | |
| Nominal coil current | Approximately 66.7 mA | |
| Nominal coil consumption | 0.8 W | |
| Coil operating voltage range | Approximately 9–14.4 V DC | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact clearance and creepage | 8 mm | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Coil-to-contact dielectric strength | 4,000 V AC | |
| Dielectric strength between open contacts | 1,500 V AC | |
| Mechanical endurance | 10 million operations | |
| Operating time | Approximately 10 ms | |
| Release time | Approximately 4 ms | |
| Protection category | RT III, wash-tight | |
| Mounting type | PCB through-hole | |
| Terminal pitch | 5 mm | |
| Dimensions | 55 × 16.5 × 16.5 mm | |
| Operating temperature | −40 to +70 °C | |
| EAN / GTIN | 8012823416052 | |
| Application | Safety-related control, industrial automation and contact-state monitoring |
The Finder 50.16.9.012.5420 is a six-pole safety relay with Type A forcibly guided contacts, designed for use in safety-related control electronics, machinery monitoring circuits, industrial automation and PCB-based switching assemblies.
The relay uses a 12 V DC nominal coil with a resistance of 180 Ω, approximately 66.7 mA nominal coil current and 0.8 W nominal coil consumption.
The relay has six forcibly guided contacts, comprising four normally open contacts (4 NO) and two normally closed contacts (2 NC). This configuration supports switching and contact-state monitoring within appropriately designed control systems.
Type A forcibly guided contacts are mechanically linked in accordance with EN 61810-3. This arrangement helps a properly designed monitoring circuit detect certain contact failures, including welded contacts. The relay must be incorporated into a validated safety system to achieve the required safety performance.
The relay is designed for PCB through-hole mounting and features a 5 mm terminal pitch, compact 55 × 16.5 × 16.5 mm housing and RT III wash-tight construction. It is intended for integration into electronic assemblies rather than direct DIN-rail mounting.
Finder 50 Series relays combine forcibly guided contact technology, compact PCB construction and dependable electromechanical switching. Designed for integration into appropriately engineered safety-related control systems, they provide a practical solution for automation engineers, machinery manufacturers and industrial electronics designers requiring multi-contact switching and contact-state monitoring.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.