Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 50.12.9.006.1000 force-guided PCB relay with a 6 V DC coil, two 8 A changeover contacts, silver nickel contact material and EN 61810-3 Type B construction for industrial control, monitoring and safety-related electronic circuits.
£10.35
The Finder 50.12.9.006.1000 is a compact 8 A force-guided electromechanical relay designed for printed circuit board integration in industrial control, monitoring and safety-related applications. Part of the Finder 50 Series, this specialist PCB relay features mechanically linked contacts manufactured in accordance with EN 61810-3 Type B, previously EN 50205, providing defined contact behaviour that can be used in appropriately designed monitoring and diagnostic circuits.
Featuring a 6 V DC nominal operating coil and two changeover contacts (2 CO / DPDT), the Finder 50.12.9.006.1000 provides flexible electrical switching in a compact PCB-mounted package. Its 8 A rated contact current, silver nickel (AgNi) contacts and 50 Ω nominal coil resistance make it suitable for compatible industrial and electronic control circuits where reliable contact operation and defined switching behaviour are important.
Unlike a conventional general-purpose relay, the Finder 50.12 uses a force-guided contact mechanism intended to prevent specified normally open and normally closed contacts from being closed simultaneously under defined fault conditions. The relay also provides 8 mm coil-to-contact insulation separation, 6 kV impulse withstand capability and RT II flux-proof construction. Its compact dimensions of approximately 29 × 12.4 × 25 mm make it particularly suitable for densely populated industrial control PCBs.
The distinguishing feature of the Finder 50.12.9.006.1000 is its force-guided contact mechanism. In an ordinary relay, normally open and normally closed contacts may not have a defined relationship after certain mechanical failures. Force-guided relays use mechanically linked contact elements so that, under the conditions defined by the relevant standard, a welded contact prevents the corresponding monitored contact from returning to an apparently normal state.
The Type B contact arrangement requires particular care when designing safety-monitoring circuits. Although the relay has two changeover contacts, the standard's force-guided relationship applies to specified normally open and normally closed contact combinations, rather than treating every possible contact pairing as an independent safety-rated combination. Circuit designers should use the manufacturer's approved contact combinations and PCB terminal diagram when implementing feedback monitoring.
When the 6 V DC coil is energised, the relay changes the state of its contacts; removing the coil supply allows the mechanism to return to its rest position. The relay's 8 mm insulation separation, 6 kV impulse withstand rating and compact PCB footprint support integration into industrial electronic equipment. A force-guided relay is a component of a safety-related system, not a complete safety function by itself; the required safety integrity or performance level must be established for the finished circuit.
Tick the specs you need, then view products that match.
| Device Type | Positively Guided Relay | |
|---|---|---|
| Mounting Type | PCB | |
| Switching Current (A) | 8 A | |
| Manufacturer | Finder | |
| Series | Finder 50 Series | |
| Manufacturer part number | 50.12.9.006.1000 | |
| Product type | Force-guided electromechanical PCB relay | |
| Relay model | 50.12 | |
| Contact guidance classification | EN 61810-3 Type B | |
| Previous contact guidance standard | EN 50205 Type B | |
| Contact configuration | 2 CO (DPDT / 2 Form C) | |
| Number of poles | 2 | |
| Rated contact current | 8 A | |
| Maximum peak contact current | 15 A | |
| Contact material | Silver nickel (AgNi) | |
| Nominal coil voltage | 6 V DC | |
| Coil supply type | DC | |
| Nominal coil resistance | 50 Ω | |
| Nominal coil consumption | 0.7 W | |
| Minimum operating coil voltage | 4.5 V DC | |
| Maximum specified coil voltage | 7.2 V DC | |
| Typical operate time | 10 ms | |
| Typical release time | 4 ms | |
| Coil-to-contact insulation separation | 8 mm | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Coil-to-contact dielectric strength | 4000 V AC | |
| Dielectric strength between open contacts | 1500 V AC | |
| Electrical endurance | 100,000 cycles under specified test conditions | |
| Operating temperature range | −40 to +70 °C | |
| Environmental protection | RT II, flux-proof | |
| Mounting type | Printed circuit board (PCB) | |
| Termination type | Through-hole solder pins | |
| Contact pin pitch | 5 mm | |
| Number of PCB terminals | 8 | |
| Length | 29 mm | |
| Width | 12.4 mm | |
| Height | 25 mm | |
| Contact material composition | Cadmium-free | |
| Application category | Industrial control, monitoring and safety-related electronics |
The Finder 50.12.9.006.1000 is a force-guided PCB relay designed for industrial control, monitoring and safety-related electronic circuits. It uses a 6 V DC coil and two changeover contacts, with a mechanically guided contact arrangement that can assist fault detection in appropriately engineered systems.
Force-guided contacts are mechanically linked so that specified normally open and normally closed contacts cannot both indicate a closed state under the fault conditions defined by EN 61810-3. This characteristic can be used to detect certain contact welding failures through an appropriately designed feedback circuit.
The Finder 50.12.9.006.1000 uses a 6 V DC nominal coil with a 50 Ω nominal resistance and approximately 0.7 W nominal coil consumption. The specified operating voltage limits should be observed when designing the control circuit.
The relay has two changeover contacts (2 CO / DPDT), each rated at 8 A under the applicable conditions. For safety-related monitoring, only the contact combinations specified by Finder for the Type B force-guided arrangement should be used.
The relay is designed for through-hole PCB mounting with solder terminals and a 5 mm contact pin pitch. Its housing measures approximately 29 × 12.4 × 25 mm. The manufacturer's PCB footprint, terminal assignment and soldering recommendations should be followed during installation.
Finder 50 Series force-guided relays are designed for industrial monitoring and safety-related control applications requiring defined mechanical contact behaviour. The Finder 50.12.9.006.1000 combines a 6 V DC coil, dual 8 A changeover contacts and EN 61810-3 Type B construction in a compact PCB-mounted package.