Finder 486181101060SPA - 48 Series Relay interface modules

Finder 486181101060SPA – 48 Series Relay interface modules

Finder 486181101060SPA modular DIN rail interface relay featuring a 110 V AC control coil, 16 A SPDT changeover contact, AgNi contacts, screw-clamp terminals, plastic retaining clip and integrated LED plus varistor protection for industrial automation and electrical control panels.

SKU: 486181101060SPAAlt SKU: 486181101060SPAMPN: 486181101060SPA
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 486181101060SPA DIN Rail Interface Relay Module?

The Finder 486181101060SPA, also identified as 48.61.8.110.1060SPA, is a compact 16 A DIN rail interface relay module designed for dependable electrical switching in industrial automation, control panels, machinery and building management systems. Part of the established Finder 48 Series, this complete relay interface combines an electromechanical changeover relay, a compatible socket, an LED status indicator and integrated coil protection in a convenient modular assembly.

Featuring a 110 V AC control coil and a single-pole double-throw (SPDT / 1 CO) contact configuration, the Finder 486181101060SPA provides a practical interface between an electrical control signal and a separate switched load. Its 16 A rated contact current and 250 V AC rated contact voltage make it suitable for a wide range of appropriately rated industrial and commercial switching applications.

This particular version incorporates silver nickel (AgNi) contacts, screw-clamp terminals, a plastic retaining clip and an LED plus varistor protection module. Its slim 15.8 mm width helps conserve valuable DIN rail space, while the removable relay construction simplifies maintenance and replacement. The Finder 486181101060SPA is therefore an excellent solution for control panel builders, industrial electricians, automation engineers and OEM equipment manufacturers requiring an accessible, space-efficient relay interface.

Key Advantages

  • 16 A rated changeover contact for switching appropriately rated industrial and electrical loads.
  • 110 V AC control voltage for compatible industrial AC control systems.
  • SPDT / 1 CO contact arrangement provides normally open and normally closed switching functions.
  • Complete DIN rail relay interface assembly combines the relay, socket and associated accessories.
  • Integrated LED indicator provides convenient visual indication of the control supply.
  • Built-in varistor protection helps suppress voltage transients associated with coil switching.
  • Silver nickel (AgNi) contacts provide dependable electromechanical switching.
  • Screw-clamp terminals allow straightforward connection of compatible control and load wiring.
  • 15.8 mm slimline width helps maximise space in electrical control cabinets.
  • Plastic retaining clip secures the relay in its socket while allowing convenient removal.
  • DIN rail mounting supports rapid installation in standard industrial enclosures.
  • Removable relay design simplifies inspection, maintenance and replacement.
  • IP20 protection provides finger-safe protection when correctly installed in a suitable enclosure.
  • Suitable for PLC interfaces, automation systems and general industrial switching applications.

Key Features

  • Finder 48 Series modular interface relay.
  • Type 48.61 single-pole relay interface.
  • 110 V AC nominal control voltage.
  • 50/60 Hz AC control operation.
  • 16 A rated contact current.
  • 1 CO / SPDT changeover contact configuration.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage, subject to specified operating conditions.
  • Silver nickel (AgNi) contact material.
  • Integrated LED control supply indicator.
  • Varistor coil protection module.
  • Screw-clamp electrical terminals.
  • Plastic relay retaining clip.
  • 35 mm DIN rail mounting.
  • 15.8 mm module width.
  • IP20 enclosure protection rating.
  • Approximately 78.6 mm overall height.
  • Approximately 71.8–75.3 mm installation depth, depending on the referenced assembly measurement.
  • Removable electromechanical relay.
  • Monostable, non-latching operation.
  • Suitable for industrial automation and electrical control interfaces.

Efficient DIN Rail Switching with LED Indication and Varistor Protection

The Finder 486181101060SPA provides an effective interface between a 110 V AC control signal and an external electrical load. When the control coil is energised, the relay transfers its common contact from the normally closed terminal to the normally open terminal. When the coil is de-energised, the contact returns to its normal position. This changeover action allows the module to operate auxiliary loads, provide control feedback or switch between alternative circuit states.

The integrated LED indicator makes it easier for technicians to identify when the control voltage is present, supporting faster fault diagnosis and routine maintenance. The accompanying varistor protection module helps limit voltage transients generated during coil switching, reducing electrical disturbances in appropriately designed control systems. The LED indicates the control supply condition rather than independently confirming that the load contacts have changed state.

Its 15.8 mm slimline housing makes the Finder 48.61 interface particularly useful in control panels where DIN rail space is limited. The complete socket assembly provides accessible screw-clamp terminals, while the plastic retaining clip helps secure the removable relay. This combination supports efficient panel wiring, straightforward commissioning and convenient replacement when servicing equipment.

A Practical Interface Between Control Signals and Electrical Loads

The Finder 48 Series is designed to simplify the connection between control equipment and field devices. The Finder 486181101060SPA can be used to translate a compatible AC control signal into an isolated electromechanical contact output, allowing control systems to operate suitably rated electrical equipment without directly carrying the load current through the control circuit.

For industrial installations, the SPDT changeover contact provides flexibility in designing normally open and normally closed control functions. Typical uses include signalling, auxiliary interlocking, lighting control, equipment enable circuits and general-purpose load switching. Correct wiring, protective devices and load-specific switching ratings must be observed, particularly when switching motors, inductive loads or equipment with high inrush current.

Typical Applications

  • Industrial automation and machine control systems.
  • PLC output interfaces and control signal isolation.
  • Electrical control panels and switchgear assemblies.
  • Building automation and management systems.
  • Lighting control and auxiliary switching circuits.
  • Heating, ventilation and air conditioning control panels.
  • Motor control signalling and auxiliary relay circuits.
  • Electrical interlocking and changeover control functions.
  • Industrial machinery and production equipment.
  • Pump and fan control interfaces.
  • Alarm, monitoring and signalling systems.
  • OEM electrical equipment and industrial control assemblies.
  • DIN rail relay replacement and control panel maintenance.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Interface Relay
Mounting Type DIN rail
Load Voltage 400 V AC
Switching Current (A) 16 A
Manufacturer Finder
Series 48 Series Interface Relay Modules
Product reference 486181101060SPA
Formatted part number 48.61.8.110.1060SPA
Relay type 48.61
Product type Modular electromechanical interface relay assembly
Supplied configuration Relay, socket, retaining clip and indication/protection module
Contact configuration Single-pole double-throw (SPDT / 1 CO)
Number of poles 1
Number of changeover contacts 1
Number of normally open contacts 1 within the changeover arrangement
Number of normally closed contacts 1 within the changeover arrangement
Nominal control voltage 110 V AC
Control voltage type AC
Nominal frequency 50/60 Hz
Control polarity Non-polarised AC input
Coil consumption Approximately 1.2 VA, standard 48.61 AC relay rating
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Resistive load rating 16 A at 250 V AC, subject to applicable operating conditions
DC resistive load rating Up to 16 A at 30 V DC, subject to the manufacturer's switching limits
Contact arrangement 1 normally open and 1 normally closed contact sharing a common terminal
Contact material Silver nickel (AgNi)
Relay operation Monostable / non-latching
Switching mechanism Electromechanical
Typical operate time Approximately 7 ms, standard 48.61 series rating
Release time Dependent on the installed varistor suppression module and operating conditions
Mechanical life Up to 10 million operations, standard AC relay series rating
Electrical life Load-dependent; consult Finder switching-life data
LED indication Yes
Coil protection Integrated varistor
Retaining clip Plastic
Connection technology Screw-clamp terminals
Mounting type DIN rail mounting
DIN rail compatibility 35 mm DIN rail
Module width 15.8 mm
Overall height Approximately 78.6 mm
Installation depth Approximately 71.8–75.3 mm, depending on measurement convention
Ingress protection IP20
Operating ambient temperature Typically −40 to +70 °C for the 48.61 relay family, subject to complete assembly limits
EAN / GTIN 8012823451916
Application category Industrial interface relays, PLC switching, control panels and automation

Frequently Asked Questions

What is the Finder 486181101060SPA used for?

The Finder 486181101060SPA is a 16 A DIN rail interface relay module used for switching electrical circuits in industrial automation, machinery, control panels and building management systems. It provides a single changeover contact operated by a 110 V AC control supply.

What control voltage does the Finder 486181101060SPA require?

The module uses a 110 V AC nominal control voltage, suitable for compatible 50/60 Hz AC control systems. It is not a 110 V DC relay and should only be connected to a supply meeting the manufacturer's specified electrical requirements.

What is the contact rating of the Finder 486181101060SPA?

The Finder 486181101060SPA features a 16 A rated SPDT changeover contact with a 250 V AC rated contact voltage. The permissible switching load depends on the load type, switching duty, ambient conditions and the manufacturer's specifications.

Does the Finder 486181101060SPA include an LED and surge protection?

Yes. This module includes an LED control supply indicator and an integrated varistor protection module. The LED provides visual indication of the control voltage, while the varistor helps suppress switching transients associated with the relay coil.

How is the Finder 486181101060SPA installed?

The Finder 486181101060SPA is supplied as a DIN rail interface relay assembly with screw-clamp terminals and a plastic retaining clip. It mounts onto a compatible 35 mm DIN rail and occupies approximately 15.8 mm of rail width. Installation should follow Finder's terminal diagram and applicable electrical safety requirements.

Trusted by Industrial Automation Professionals Worldwide

Finder 48 Series interface relay modules are designed for reliable and convenient electrical switching in industrial automation and control panel applications. The Finder 486181101060SPA combines a 110 V AC control input, a 16 A changeover contact, silver nickel contacts, integrated LED indication, varistor coil protection and a slim DIN rail housing, providing a practical interface solution for panel builders, maintenance technicians and industrial automation engineers.