Finder 27.22.8.230.4000 Series 27 electromechanical impulse relay with a 230 V AC operating coil and two normally open contacts for mechanically maintained multi-point lighting control using momentary push buttons.
£11.02
The Finder 27.22.8.230.4000 is a modular electromechanical impulse relay designed for convenient lighting control and electrical switching in residential and commercial installations. Part of the Finder Series 27, it provides a practical solution for controlling lighting circuits from multiple push-button locations without requiring conventional multi-way switching arrangements.
Featuring a 230 V AC operating coil and two normally open (2 NO) contacts, the relay uses an impulse-operated, mechanically maintained switching mechanism. Each suitable control pulse advances the switching mechanism, allowing connected lighting circuits to be switched without requiring the operating coil to remain continuously energised.
The Finder 27.22.8.230.4000 is particularly useful for corridors, staircases, communal areas and other installations where lighting needs to be operated from several positions. Its impulse relay design reduces the need for complex switching wiring while providing a dependable mechanical switching function for compatible electrical loads.
The Finder 27.22.8.230.4000 operates using short electrical impulses applied to its 230 V AC coil. Rather than maintaining the coil energised throughout the operating period, the relay uses a mechanical mechanism to retain its selected contact position after the control pulse ends.
This operating principle makes impulse relays particularly suitable for lighting installations with multiple push-button control points. Push buttons can be positioned at entrances, exits, stair landings and other convenient locations, allowing the same lighting circuit to be controlled from several positions.
The relay's two normally open contacts provide switching capability for compatible electrical circuits. The switching sequence and circuit arrangement should be implemented according to the applicable Finder wiring diagram, with the connected loads selected within the manufacturer's specified ratings.
Finder Series 27 impulse relays offer a practical alternative to traditional multi-way lighting switching arrangements, combining mechanical contact retention with straightforward momentary control for building electrical installations.
Tick the specs you need, then view products that match.
| Device Type | Latching / Impulse Relay | |
|---|---|---|
| Timing Function | Pulse | |
| Manufacturer | Finder | |
| Series | Series 27 | |
| Model | 27.22.8.230.4000 | |
| Product type | Electromechanical impulse relay | |
| Operating principle | Impulse-operated, mechanically maintained | |
| Rated coil voltage | 230 V AC | |
| Coil supply | Alternating current | |
| AC supply frequency | 50/60 Hz | |
| Contact configuration | 2 NO | |
| Number of switching contacts | 2 | |
| Control method | Momentary electrical impulse | |
| Contact retention | Mechanical | |
| Typical application | Multi-point lighting control | |
| Installation environment | Suitable electrical enclosure |
The Finder 27.22.8.230.4000 is an electromechanical impulse relay designed primarily for lighting control. It allows compatible lighting circuits to be operated using momentary push buttons installed at multiple locations.
The relay uses a 230 V AC operating coil for impulse control. The control circuit must be designed for the specified coil voltage and installed in accordance with applicable electrical regulations.
An impulse relay is a switching device that changes its mechanically maintained contact state in response to a short electrical control pulse. Unlike a conventional monostable relay, it does not require continuous coil energisation to maintain its selected switching position.
The Finder 27.22.8.230.4000 features two normally open contacts, providing switching capability for compatible electrical circuits.
Yes. Multi-point lighting control is a principal application of Finder Series 27 impulse relays. Compatible momentary push buttons can be connected according to the manufacturer's wiring diagram to operate the relay from different locations.
No. The relay uses a mechanically maintained switching mechanism, so the coil is energised only during the appropriate control pulse rather than continuously throughout the lighting operating period.
No. A conventional monostable installation relay normally returns to its original contact position when coil power is removed. The Finder 27.22.8.230.4000 is an impulse relay that mechanically retains its switching state after a control pulse.
Yes. It is suitable for compatible commercial lighting control applications, including corridors, staircases and communal areas, provided the electrical installation and connected loads comply with the manufacturer's ratings.
The relay is intended for operation using momentary push-button controls that provide an appropriate electrical impulse to its operating coil.
Finder Series 27 impulse relays provide practical, mechanically maintained switching for multi-point lighting control, helping electrical installers simplify push-button wiring arrangements in residential and commercial buildings.