Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 66.82.9.024.4600 is a flange-mounted 30 A electromagnetic power relay featuring a 24 V DC coil, two normally open silver tin oxide contacts, a minimum 1.5 mm contact gap and Faston 250 terminals for industrial electrical switching and power conversion applications.
£12.50
The Finder 66.82.9.024.4600 is a robust 30 A electromagnetic power relay designed for industrial power switching, automation equipment and electrical control applications. Featuring a 24 V DC operating coil, two normally open contacts (2 NO / DPST-NO) and a minimum 1.5 mm contact gap, it provides dependable switching with increased separation between open contacts.
Part of the established Finder Series 66, this relay combines high-current switching capability with silver tin oxide (AgSnO₂) contacts, reinforced coil-to-contact insulation and a practical flange-mounted construction. Its Faston 250 quick-connect terminals enable straightforward integration into industrial machinery, power conversion equipment and OEM electrical assemblies.
The 66.82.9.024.4600 is particularly suitable for applications requiring a defined open-contact gap, including appropriately designed renewable energy and inverter switching systems. With a 30 A resistive contact rating at 250 V AC, 1.7 W DC coil consumption and an operating temperature range of −40 to +70 °C, it offers a versatile solution for industrial control engineers.
The Finder 66.82.9.024.4600 operates through an electromagnetic switching mechanism controlled by its 24 V DC coil. When the coil is energised, the relay closes both normally open contacts, allowing the connected electrical loads to operate. Removing the coil supply returns the contacts to their open positions, interrupting the switched circuits.
A distinguishing feature of the Finder 66.82 x60x range is its minimum 1.5 mm contact gap. This increased separation is useful in applications where a defined open-contact distance is required, including suitably designed solar inverter and power conversion systems. The relay's AgSnO₂ contacts support high-current switching, while its reinforced coil-to-contact insulation helps maintain separation between the control supply and switched loads.
The flange-mounted housing and Faston 250 terminals make the relay suitable for integration into industrial machinery, control panels and OEM equipment. Its 30 A nominal resistive contact rating must be evaluated alongside the actual load type, operating voltage, switching frequency, ambient temperature and electrical protection requirements. A 1.5 mm contact gap does not, by itself, establish suitability as a safety isolator or disconnection device.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Mounting Type | Panel | |
| Manufacturer | Finder | |
| Series | 66 Series Power Relays | |
| Model | 66.82.9.024.4600 | |
| Relay type | 66.82 | |
| Product type | Electromagnetic power relay | |
| Contact configuration | 2 NO / DPST-NO | |
| Number of poles | 2 | |
| Contact arrangement | Normally open | |
| Minimum open-contact gap | 1.5 mm | |
| Contact material | Silver tin oxide (AgSnO₂) | |
| Nominal coil voltage | 24 V DC | |
| Coil supply type | Direct current (DC) | |
| Nominal coil consumption | 1.7 W | |
| Coil resistance | 340 Ω | |
| Nominal contact current | 30 A | |
| Maximum peak contact current | 120 A under specified conditions | |
| Nominal switching voltage | 250 V AC | |
| Maximum AC switching voltage | 440 V AC | |
| Maximum DC switching voltage | 220 V DC | |
| Resistive AC contact rating | 30 A at 250 V AC | |
| Rated AC-1 resistive load | 7,500 VA | |
| Resistive DC contact rating | 25 A at 24 V DC | |
| Mechanical endurance | 10,000,000 cycles | |
| Electrical endurance | 100,000 cycles under specified rated-load conditions | |
| Typical operate time | 15 ms | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact creepage and clearance | 8 mm | |
| Operating temperature | −40 to +70 °C | |
| Mounting type | Flange / panel mounting | |
| Terminal type | Faston 250 quick-connect terminals | |
| Terminal dimensions | 6.3 × 0.8 mm | |
| Number of connection terminals | 6 | |
| Overall dimensions | 68.5 × 33.5 × 31 mm | |
| Contact-gap version | Finder Series 66 x60x | |
| Compliance | RoHS | |
| Relevant insulation standard | EN 60335-1 |
The Finder 66.82.9.024.4600 is an electromagnetic power relay used for electrical load switching in industrial machinery, automation equipment, power control systems and suitably designed renewable energy equipment. It features two normally open contacts and an increased open-contact gap.
The relay features a 24 V DC nominal operating coil with a nominal power consumption of 1.7 W and a coil resistance of 340 Ω.
2 NO means two normally open contacts. DPST-NO stands for Double Pole Single Throw – Normally Open, indicating that the relay has two separate switching circuits which close together when its coil is energised.
The Finder 66.82.9.024.4600 has a 30 A resistive contact rating at 250 V AC. The contact system also has a specified maximum peak current of 120 A under the manufacturer's defined conditions. Actual switching capability depends on the electrical load and operating conditions.
The relay features a minimum 1.5 mm open-contact gap, distinguishing it from standard contact-gap versions within the Finder Series 66 range. This provides increased physical separation between the contacts when the relay is de-energised.
The Finder Series 66 x60x relay design is relevant to solar inverter and power conversion applications requiring an increased contact gap. Suitability for a specific inverter depends on the required switching duty, isolation arrangement, applicable standards and the complete equipment design.
The Finder 66.82.9.024.4600 uses silver tin oxide (AgSnO₂) contacts, a cadmium-free contact material suitable for demanding industrial electrical switching applications.
The relay uses flange mounting and Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm. Compatible connectors, correctly rated wiring and appropriate electrical protection should be used during installation.
Both relays belong to the Finder Series 66.82 family and use a 24 V DC coil with two normally open contacts. The 66.82.9.024.4600 is an increased-contact-gap version with a minimum 1.5 mm separation, while the 66.82.9.024.4303 has a different special-version configuration. Their contact-gap requirements and applicable approvals should be checked before substitution.
Yes. The relay has a specified resistive DC contact rating of 25 A at 24 V DC. The maximum switching voltage is listed as 220 V DC, but the permissible current at higher DC voltages is substantially dependent on the manufacturer's switching characteristics and the connected load.
The Finder 66.82.9.024.4600 is specified for operation at ambient temperatures from −40 to +70 °C, subject to the manufacturer's applicable load and installation conditions.
Finder Series 66 power relays provide robust electromagnetic switching solutions for industrial machinery, electrical control equipment and power conversion systems. Their high-current contact designs, reinforced insulation and specialised increased-contact-gap configurations make them a practical choice for engineers and OEM manufacturers developing dependable industrial electrical assemblies.