66.82.9.024.4003 Finder Power relay 2pole 30A DC 24V

66.82.9.024.4003 Finder Power relay 2pole 30A DC 24V

Finder 66.82.9.024.4003 is a Series 66 DPDT electromagnetic power relay with a 24 V DC coil, silver tin oxide contacts, reinforced insulation, Faston 250 terminals and flange mounting, featuring a special-version designation associated with ATEX and hazardous-location industrial switching applications.

SKU: 66.82.9.024.4003Alt SKU: 668290244003MPN: 66.82.9.024.4003
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 66.82.9.024.4003 Power Relay?

The Finder 66.82.9.024.4003 is a specialist electromagnetic power relay from the Finder Series 66 range, designed for reliable electrical switching in industrial automation, machinery control and power management equipment. Its ordering code identifies a 24 V DC operating coil, two changeover contacts (DPDT), silver tin oxide (AgSnO2) contact material and a special version associated with ATEX and hazardous-location applications.

The Finder 66.82 configuration combines a robust electromechanical switching mechanism with Faston 250 quick-connect terminals and top-flange mounting. This construction provides a practical solution for industrial equipment requiring secure mechanical installation, accessible wiring and reliable switching of two electrical circuits using a single control signal.

Unlike standard Series 66 relays, the .4003 special-version suffix identifies a configuration intended for applications requiring additional hazardous-location considerations. Finder documents special Series 66 variants for Ex ec nC and HazLoc Class I, Division 2 applications. These special versions have different operating conditions and may have lower contact current ratings than standard 30 A versions. The exact certification, temperature classification and permissible electrical ratings of 66.82.9.024.4003 must therefore be verified against the applicable Finder documentation before installation.

Key Advantages

  • 24 V DC operating coil suitable for common industrial control supplies.
  • DPDT contact arrangement provides two independent changeover switching circuits.
  • Silver tin oxide (AgSnO2) contacts offer robust electrical switching characteristics.
  • Special .4003 version associated with ATEX and hazardous-location applications.
  • Reinforced insulation between coil and contacts supports separation of control and load circuits.
  • 8 mm creepage and clearance distances in the Series 66 insulation design.
  • Faston 250 quick-connect terminals simplify electrical connections and equipment assembly.
  • Top-flange mounting provides secure installation in machinery and electrical enclosures.
  • Two changeover contacts provide normally open and normally closed switching functions.
  • Non-latching electromechanical operation returns contacts to their normal state when coil power is removed.
  • Industrial Series 66 construction supports integration into demanding electrical control systems.
  • Cadmium-free AgSnO2 contact material offers an alternative to silver cadmium oxide contacts.

Key Features

  • Finder Series 66 industrial electromagnetic power relay.
  • Manufacturer part number: 66.82.9.024.4003.
  • 24 V DC nominal coil voltage.
  • DC-operated electromagnetic coil.
  • DPDT (2 Form C) contact configuration.
  • Two changeover contacts with normally open and normally closed connections.
  • Silver tin oxide (AgSnO2) contact material.
  • Special hazardous-location version designation.
  • Ex ec nC and HazLoc options within the Finder Series 66 range.
  • 25 A contact class associated with Finder's special version 3 relay configurations, subject to the exact approved ratings.
  • 250 V AC nominal switching voltage in the standard Series 66 contact specification.
  • Reinforced coil-to-contact insulation.
  • 6 kV coil-to-contact impulse withstand capability in the Series 66 design.
  • 8 mm creepage and clearance distances between coil and contacts.
  • Faston 250 (6.3 × 0.8 mm) quick-connect terminals.
  • Top-flange / chassis mounting.
  • Non-latching relay operation.

24 V DC Power Switching for Industrial and Hazardous-Location Control Systems

The Finder 66.82.9.024.4003 operates through a 24 V DC electromagnetic coil that controls two mechanically linked changeover contacts. When the coil is energised, each common contact transfers from its normally closed connection to its normally open connection. Removing the coil supply allows the contacts to return to their normal positions, providing straightforward switching of two circuits through a common control signal.

The DPDT configuration offers greater switching flexibility than a relay equipped only with normally open contacts. It can support circuit selection, load control, electrical interlocking and control signalling. Because normally open and normally closed contacts may have different permissible current ratings, engineers should check the applicable switching specifications for each contact path.

The silver tin oxide contacts are intended for robust electrical switching, while the Series 66 reinforced insulation design provides separation between the low-voltage DC control circuit and the connected load circuits. The standard Series 66 relay family includes 30 A contact configurations, but the special version 3 is associated with a 25 A contact class. The standard 30 A rating must not automatically be applied to this special-version part number.

For installations involving potentially explosive atmospheres, relay selection requires more than checking the contact arrangement and coil voltage. The exact ATEX, IECEx or HazLoc approval, where applicable, must be checked alongside the required equipment protection level, gas group, temperature classification, enclosure design and electrical operating limits. The Finder 66.82.9.024.4003 should only be used in a classified area when its precise approval and installation requirements have been confirmed.

The flange-mounted housing and Faston 250 terminals allow direct wiring within suitable machinery and electrical equipment. This distinguishes the Finder 66.82 design from PCB-mounted Series 66.22 relays and makes it a practical choice for industrial assemblies where secure mounting and conventional wiring are preferred.

Typical Applications

  • Industrial automation and machinery control systems.
  • 24 V DC control circuits requiring power relay switching.
  • Electrical control equipment for potentially hazardous environments, subject to certification.
  • Industrial process control and monitoring systems.
  • Electrical power management and switching assemblies.
  • Industrial heating and ventilation control equipment.
  • Manufacturing machinery and automated production equipment.
  • Electrical control panels and industrial enclosures.
  • Two-circuit changeover switching applications.
  • OEM equipment requiring specialist relay configurations.
  • Industrial electrical interlocking and control signalling.
  • Specialised electrical equipment where approved hazardous-location components are required.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Manufacturer Finder
Series 66 Series Power Relays
Manufacturer part number 66.82.9.024.4003
Product type Electromagnetic power relay
Relay operation Electromechanical, non-latching
Contact configuration DPDT (double-pole double-throw)
Contact form 2 Form C
Number of poles 2
Number of changeover contacts 2
Rated coil voltage 24 V DC
Coil type DC operated
Standard Series 66 DC coil consumption 1.7 W; confirm applicability to this special version
Contact material Silver tin oxide (AgSnO2)
Contact material characteristic Cadmium-free
Special version Version 3, associated with ATEX Ex ec nC and HazLoc Class I, Division 2 requirements
Special-version contact current class 25 A; exact approved switching ratings require confirmation
Standard Series 66 nominal switching voltage 250 V AC
Standard Series 66 maximum switching voltage 440 V AC; not an independently verified hazardous-location rating
Standard Series 66 coil-to-contact impulse withstand voltage 6 kV (1.2/50 µs)
Standard Series 66 creepage and clearance distance 8 mm between coil and contacts
Insulation design Reinforced insulation between coil and contacts
Standard Series 66 dielectric strength between open contacts 1,500 V AC
Standard Series 66 ambient temperature range −40 to +70 °C; special-version certification limits may differ
Mounting type Top-flange / chassis mounting
Terminal type Faston 250 quick-connect terminals
Terminal dimensions 6.3 × 0.8 mm
Connection method Quick-connect electrical terminals
Application category Industrial power switching and hazardous-location control equipment
Certification requirements Verify exact approval markings, installation conditions and permissible ratings for this part number

Frequently Asked Questions

What is the Finder 66.82.9.024.4003 used for?

The Finder 66.82.9.024.4003 is an industrial electromagnetic power relay designed for switching electrical loads in automation, machinery and power control equipment. It has a 24 V DC coil and two changeover contacts. Its special-version designation is associated with applications requiring additional hazardous-location considerations.

What coil voltage does the Finder 66.82.9.024.4003 require?

The relay uses a 24 V DC nominal operating coil. The standard Finder Series 66 DC coil design has a nominal consumption of approximately 1.7 W, although the exact operating limits and electrical characteristics of this special version should be checked against Finder's documentation.

Is the Finder 66.82.9.024.4003 a 25 A or 30 A relay?

The standard Finder Series 66 range includes 30 A power relays, but Finder identifies special version 3 configurations with a 25 A contact class. Because the 66.82.9.024.4003 is a special-version relay, its exact contact ratings and approved switching loads must be verified rather than assuming the standard 30 A specification applies.

What does DPDT mean on the Finder 66.82.9.024.4003?

DPDT means double-pole double-throw. The relay provides two changeover contacts, each with a common, normally open and normally closed connection. Energising the 24 V DC coil transfers both contacts simultaneously, enabling flexible switching and circuit selection.

Is the Finder 66.82.9.024.4003 suitable for hazardous locations, and how is it mounted?

The .4003 suffix identifies a special-version configuration associated with ATEX Ex ec nC and HazLoc Class I, Division 2 applications. Suitability for a particular hazardous area depends on the exact approval markings, permitted electrical ratings and installation conditions. The relay uses top-flange / chassis mounting and Faston 250 (6.3 × 0.8 mm) quick-connect terminals.

Trusted by Industrial Automation and Electrical Engineers Worldwide

Finder Series 66 power relays provide robust electromechanical switching solutions for industrial automation, machinery control and electrical power management. Combining a 24 V DC coil, silver tin oxide contacts, reinforced insulation and practical flange mounting, the Finder 66.82.9.024.4003 offers a specialist relay configuration for demanding industrial applications where the correct switching ratings and hazardous-location approvals have been verified.