66.82.9.012.0600 Finder Power relay 2pole 30A DC 12V.
The Finder 66.82.9.012.0600 is a high-current 30 A, two-pole normally open (DPST-NO) industrial power relay designed for demanding electrical switching applications. Part of the Finder 66 Series, this electromagnetic relay combines high-current switching capability, reinforced coil-to-contact insulation and a practical flange-mounting arrangement with Faston 250 quick-connect terminals.
Featuring a 12 V DC nominal operating coil and two independent normally open contacts, the Finder 66.82.9.012.0600 enables two electrical circuits to be switched simultaneously from a single control signal. Its .0600 contact configuration provides an open-contact gap of at least 1.5 mm, making it particularly suitable for equipment requiring increased contact separation, including appropriately designed photovoltaic inverter applications.
With a 250 V AC rated contact voltage, 440 V AC maximum switching voltage and 7,500 VA AC1 switching capacity, this relay is suitable for high-current resistive-load switching. Its silver-cadmium oxide (AgCdO) contacts, 6 kV coil-to-contact impulse withstand voltage and reinforced insulation make it a versatile component for industrial machinery, power control equipment and electrical automation systems.
The Finder 66.82.9.012.0600 operates through an electromagnetic coil energised by a 12 V DC control supply. When the coil is energised, both normally open contacts close, allowing the connected electrical circuits to conduct. When the coil is de-energised, the contacts return to their open positions, providing conventional non-latching relay operation.
The relay's DPST-NO contact configuration allows two independent circuits to be switched simultaneously. Unlike a two-pole changeover relay, this version does not provide normally closed contact paths. It is therefore suitable for applications where both circuits are intended to remain open until the control coil is energised.
The .0600 configuration provides a contact gap of at least 1.5 mm. This increased open-contact separation is a distinguishing feature of the Finder 66 Series normally open relay variants and is particularly relevant to appropriately designed photovoltaic inverter systems and equipment requiring specified contact separation. Suitability for a particular disconnection function must be assessed against the complete equipment design and applicable standards.
With a 30 A nominal contact rating and 7,500 VA AC1 switching capacity, the relay is capable of switching substantial resistive electrical loads. Its 440 V AC maximum switching voltage provides flexibility for suitable industrial circuits. Motors, inductive loads and DC circuits must be evaluated using the appropriate switching ratings rather than the nominal AC1 capacity alone.
The Finder 66.82.9.012.0600 incorporates reinforced insulation between the coil and contact circuits. Its 8 mm creepage and clearance distances, together with a 6 kV impulse withstand rating, support insulation coordination between low-voltage control electronics and higher-voltage load circuits.
Unlike the PCB-mounted Finder 66.22 versions, the 66.82 construction uses a flange-mounted housing and Faston 250 terminals. This enables secure mechanical installation and direct quick-connect wiring in industrial control cabinets, machinery and power switching equipment.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Load Voltage | 440 V AC | |
| Switching Current (A) | 30 A | |
| Manufacturer | Finder | |
| Series | 66 Series | |
| Type | 66.82 | |
| Model | 66.82.9.012.0600 | |
| Manufacturer part number | 66.82.9.012.0600 | |
| Product type | Industrial electromagnetic power relay | |
| Contact configuration | DPST-NO / 2 Form A | |
| Number of poles | 2 | |
| Number of normally open contacts | 2 | |
| Rated contact current | 30 A | |
| Maximum peak contact current | 50 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 440 V AC | |
| Rated switching capacity (AC1) | 7,500 VA | |
| Rated switching capacity (AC15 at 230 V AC) | 1,200 VA | |
| Single-phase motor rating at 230 V AC | 1.5 kW | |
| DC1 breaking capacity at 30 V DC | 30 A | |
| DC1 breaking capacity at 110 V DC | 1.2 A | |
| DC1 breaking capacity at 220 V DC | 0.5 A | |
| Minimum switching load | 1,000 mW | |
| Open-contact gap | At least 1.5 mm | |
| Nominal coil voltage | 12 V DC | |
| Coil supply type | DC | |
| Coil operating voltage range | 9.6–13.2 V DC | |
| Nominal coil resistance | 85 Ω | |
| Nominal coil current | Approximately 141 mA | |
| Nominal DC coil consumption | 1.7 W | |
| Contact material | Silver-cadmium oxide (AgCdO) | |
| Contact arrangement option | Normally open contacts with increased contact separation | |
| Option configuration | .0600 | |
| Relay operation | Electromagnetic, monostable | |
| Mechanical endurance | 10 million cycles | |
| Electrical endurance at rated AC1 load | 100,000 cycles | |
| Typical operate time | 15 ms | |
| Typical release time | 4 ms | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact creepage distance | 8 mm | |
| Coil-to-contact clearance distance | 8 mm | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Coil-to-contact dielectric strength | 4,000 V AC | |
| Dielectric strength between open contacts | 2,500 V AC | |
| Operating ambient temperature | −40 to +70 °C | |
| Environmental protection category | RT II | |
| Mounting type | Flange mounting | |
| Connection type | Faston 250 quick-connect terminals | |
| Terminal dimensions | 6.3 × 0.8 mm | |
| Dimensions | 68.5 × 33.5 × 31 mm | |
| Approximate weight | 85 g | |
| Application category | Industrial power switching, photovoltaic equipment and electrical automation |
The Finder 66.82.9.012.0600 is a 30 A, two-pole normally open industrial power relay used for electrical switching in industrial machinery, power control equipment, automation systems and appropriately designed photovoltaic inverter applications.
The relay has a nominal 12 V DC operating coil, a nominal resistance of 85 Ω and approximately 1.7 W coil consumption. Its specified operating voltage range is 9.6–13.2 V DC.
No. The relay has two normally open contacts (DPST-NO), each with an open-contact gap of at least 1.5 mm. Both contacts close when the relay coil is energised.
The Finder 66.82.9.012.0600 belongs to a relay family designed for applications including photovoltaic inverter equipment. Its minimum 1.5 mm contact gap and reinforced coil-to-contact insulation support such designs, subject to the complete inverter's applicable electrical and safety requirements.
The relay has a 30 A nominal contact rating, 250 V AC rated contact voltage and 7,500 VA AC1 switching capacity. It is designed for flange mounting and uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm.
Finder 66 Series power relays provide dependable high-current electromagnetic switching for industrial machinery, electrical control equipment and power electronics. The Finder 66.82.9.012.0600 combines two 30 A normally open contacts, a 12 V DC coil, increased contact separation, reinforced insulation and flange-mounted Faston 250 connections for demanding industrial switching applications.