Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 66.82.8.240.1000 is a Finder 66 Series flange-mounted electromechanical power relay featuring a 240 V AC coil, two changeover contacts, a 30 A normally open contact rating and Faston quick-connect terminals for industrial electrical switching applications.
The Finder 66.82.8.240.1000 is a 30 A electromechanical power relay from the Finder 66 Series, designed for switching high-current electrical loads in industrial automation, heating equipment, machinery and power control systems. Its flange-mounted construction and Faston quick-connect terminals provide a practical solution for integration into electrical panels and OEM equipment.
Featuring a 240 V AC operating coil and two changeover contacts (2 CO / DPDT), the relay enables two circuits to be switched between normally closed and normally open positions through a single control signal. The changeover configuration provides flexibility for electrical control, load transfer and auxiliary switching applications.
The Finder 66 Series combines a 30 A normally open contact rating, a 10 A normally closed contact rating and reinforced insulation between the coil and contacts. With a rated contact voltage of 250 V AC and a maximum switching voltage of 440 V AC, the 66.82.8.240.1000 is suited to appropriately rated industrial electrical switching duties.
Electromechanical power relays allow a control circuit to operate electrical loads through mechanically actuated contacts. When the 240 V AC coil of the Finder 66.82.8.240.1000 is energised, its two changeover contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the contacts return to their original states.
This switching arrangement is useful for machinery control, electrical load selection, heating equipment and auxiliary control circuits. The relay's flange-mounted construction allows installation on a suitable mounting surface, while Faston terminals facilitate wiring. Contact ratings must be assessed against the actual load type, particularly where motors, transformers or other inductive equipment produce elevated starting currents.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Load Voltage | 440 V AC | |
| Manufacturer | Finder | |
| Series | 66 Series | |
| Manufacturer part number | 66.82.8.240.1000 | |
| Product type | Electromechanical power relay | |
| Relay operation | Non-latching | |
| Contact configuration | 2 CO (DPDT) | |
| Number of poles | 2 | |
| Nominal coil voltage | 240 V AC | |
| Coil frequency | 50/60 Hz | |
| Nominal AC coil consumption | 3.6 VA at 50 Hz | |
| Rated normally open contact current | 30 A | |
| Rated normally closed contact current | 10 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 440 V AC | |
| Rated resistive load (AC1) | 7500 VA (NO) / 2500 VA (NC) | |
| Rated inductive load (AC15, 230 V AC) | 1200 VA (NO) | |
| Single-phase motor rating (230 V AC) | 1.5 kW (NO) | |
| DC1 breaking capacity at 24 V DC | 25 A (NO) | |
| Mounting type | Flange mounting | |
| Connection type | Faston 250 quick-connect terminals | |
| Terminal dimensions | 6.3 × 0.8 mm | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Creepage and clearance distance | 8 mm between coil and contacts | |
| Dielectric strength between open contacts | 1500 V AC | |
| Ambient operating temperature | −40 to +70 °C | |
| Environmental protection | RT II |
The Finder 66.82.8.240.1000 is an electromechanical power relay for switching electrical loads in industrial automation, machinery, heating equipment and power control systems.
The relay uses a 240 V AC nominal operating coil designed for a 50/60 Hz supply. The 66 Series AC coil specification lists a nominal consumption of 3.6 VA at 50 Hz.
The Finder 66.82 Series changeover configuration is rated at 30 A for normally open contacts and 10 A for normally closed contacts under specified conditions. Actual load suitability depends on the switching voltage, load category and operating requirements.
Yes. The relay has a 2 CO (DPDT) contact configuration, providing two changeover poles, each with normally open and normally closed contact positions.
The Finder 66.82 relay design uses flange mounting and Faston 250 quick-connect terminals, allowing installation onto a suitable mounting surface and connection using compatible electrical terminals.
Finder 66 Series power relays offer high-current switching capabilities for industrial automation, electrical equipment and power control applications. Their robust electromagnetic construction, versatile contact configurations and practical mounting options make them suitable for panel builders, equipment manufacturers and electrical engineering applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.