Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
66.82.8.120.0303 Finder Power relay 2pole 30A 120/125V.
The Finder 66.82.8.120.0303 is an industrial electromechanical power relay from the Finder 66 Series, designed for electrical load switching, machinery control and industrial automation applications. Featuring a 120 V AC operating coil and two normally open contacts (2 NO), this relay provides a practical solution for controlling two electrical circuits through a common control signal.
The Finder 66.82.8.120.0303 combines a dual-contact switching arrangement with electromagnetic relay technology. Its two normally open contact paths allow separate electrical circuits to be switched together, making it suitable for auxiliary load control, equipment operation and industrial electrical switching applications.
As part of Finder's established 66 Series power relay family, this model is intended for equipment requiring dependable AC-controlled switching. The complete 66.82.8.120.0303 manufacturer part number identifies the required configuration and should be used when specifying replacement components or selecting relays for new electrical installations.
The Finder 66.82.8.120.0303 provides an electromechanical interface between a 120 V AC control circuit and two separately connected electrical loads. When the operating coil is energised, the relay's electromagnetic mechanism closes both normally open contacts, completing the connected circuits. When coil power is removed, the contacts return to their open positions.
The 2 NO contact configuration is useful where one control command must operate two electrical circuits. For example, one contact may control an auxiliary load while the other operates a separate equipment function. This arrangement can simplify control wiring in compatible industrial machinery, electrical panels and automation equipment.
Before installation, engineers should verify the contact current rating, switching voltage, load category, inrush current, coil frequency, terminal arrangement, mounting requirements and any special characteristics of the .0303 variant against Finder documentation for the exact part number. The 120 V AC coil rating specifies the nominal operating supply and does not determine the permissible voltage across the relay contacts.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 66 Series | |
| Manufacturer part number | 66.82.8.120.0303 | |
| Product category | Industrial electromechanical power relay | |
| Relay technology | Electromechanical | |
| Contact configuration | 2 NO (two normally open contacts) | |
| Number of poles | 2 | |
| Nominal coil voltage | 120 V AC | |
| Coil supply type | Alternating current (AC) | |
| Operating principle | Electromagnetic, monostable | |
| Contact operating arrangement | Two normally open switching circuits | |
| Contact state when de-energised | Both normally open contacts open | |
| Product family | Finder 66 Series Power Relays |
The Finder 66.82.8.120.0303 is an industrial electromechanical power relay used for switching two electrical circuits through a common AC control signal. Typical applications include machinery control, auxiliary load switching and industrial automation equipment.
The relay has a nominal operating coil voltage of 120 V AC. It must be connected to a compatible alternating-current control supply within the manufacturer's specified operating limits. The coil frequency and voltage tolerance should be confirmed before installation.
The relay features two normally open contacts (2 NO). Both contacts are open when the relay is de-energised and close when the operating coil is energised, allowing two separate electrical circuits to be switched together.
No. The Finder 66.82.8.120.0303 uses a monostable electromechanical operating principle. Its normally open contacts close while the coil is energised and return to their open positions when the coil is de-energised.
Before installation, confirm the 120 V AC coil supply, two normally open contact arrangement, applicable switching ratings, coil frequency, terminal configuration, mounting requirements and any special characteristics of the .0303 variant against Finder documentation for the exact part number. Connected loads must remain within the relay's specified operating limits.
Finder 66 Series power relays provide electromechanical switching solutions for industrial machinery, electrical control and automation equipment. The Finder 66.82.8.120.0303 combines a 120 V AC operating coil with two normally open contacts, offering dual-circuit switching for compatible industrial electrical applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.