66.22.8.024.0001 Finder Power relay 2pole 30A 24V.
The Finder 66.22.8.024.0001 is an industrial electromechanical power relay from the Finder 66 Series, designed for electrical load switching, machinery control and industrial automation applications. Featuring a 24 V AC operating coil and two normally open contacts (2 NO), this relay provides a practical solution for switching two separate electrical circuits through a common control signal.
The Finder 66.22.8.024.0001 combines a dual-contact arrangement with electromagnetic switching technology. Both normally open contacts are operated by the same coil, allowing two independent load circuits to be switched together while maintaining electrical separation between the control and contact circuits.
As part of Finder's established 66 Series power relay range, this model is suitable for compatible industrial equipment requiring AC-controlled switching. Its contact configuration makes it particularly useful for auxiliary power switching, machinery operation, electrical control panels and OEM equipment where two normally open switching functions are required.
The Finder 66.22.8.024.0001 provides an electromechanical interface between a 24 V AC control circuit and two separately connected electrical loads. When the operating coil is energised, the relay's electromagnetic mechanism closes both normally open contacts, completing the connected circuits. When coil power is removed, the contacts return to their open positions.
The 2 NO contact configuration is useful where a single control command must switch two independent circuits. For example, one contact may operate an auxiliary electrical load while the other controls a separate equipment function. This arrangement can simplify control logic in suitable machinery, automation and electrical equipment applications.
Before installation, engineers should verify the contact current rating, switching voltage, load category, inrush current, coil frequency, connection arrangement and mounting requirements against Finder documentation for the exact 66.22.8.024.0001 variant. The 24 V AC coil rating specifies the nominal control supply and does not determine the permissible voltage across the relay contacts. Both switching circuits must remain within the manufacturer's specified electrical limits.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Manufacturer | Finder | |
| Series | 66 Series | |
| Manufacturer part number | 66.22.8.024.0001 | |
| Product category | Industrial electromechanical power relay | |
| Relay technology | Electromechanical | |
| Contact configuration | 2 NO (two normally open contacts) | |
| Number of poles | 2 | |
| Nominal coil voltage | 24 V AC | |
| Coil supply type | Alternating current (AC) | |
| Operating principle | Electromagnetic, monostable | |
| Contact operating arrangement | Two independent normally open switching circuits | |
| Contact state when de-energised | Both normally open contacts open | |
| Product family | Finder 66 Series Power Relays |
The Finder 66.22.8.024.0001 is an industrial electromechanical power relay used for switching two electrical circuits through a common AC control signal. Typical applications include machinery control, auxiliary load switching and industrial automation equipment.
The relay has a nominal operating coil voltage of 24 V AC. It must be connected to a compatible alternating-current control supply within the manufacturer's specified operating limits. The coil frequency and voltage tolerance should be confirmed before installation.
The relay features two normally open contacts (2 NO). Both contacts are open when the relay is de-energised and close when the operating coil is energised, allowing two separate electrical circuits to be switched together.
No. The Finder 66.22.8.024.0001 uses a monostable electromechanical operating principle. Its normally open contacts close while the coil is energised and return to their open positions when the coil is de-energised.
Before installation, confirm the 24 V AC coil supply, two normally open contact arrangement, applicable switching ratings, coil frequency, terminal configuration, mounting requirements and any special characteristics of the .0001 variant against Finder documentation for the exact part number. Connected loads must remain within the relay's specified operating limits.
Finder 66 Series power relays provide electromechanical switching solutions for industrial machinery, electrical control and automation equipment. The Finder 66.22.8.024.0001 combines a 24 V AC operating coil with two normally open contacts, offering flexible dual-circuit switching for compatible industrial electrical applications.