65.31.8.012.4300 Finder Power relay 1NO 30A 12VNO

65.31.8.012.4300 Finder Power relay 1NO 30A 12VNO

65.31.8.012.4300 Finder Power relay 1NO 30A 12VNO.

SKU: 65.31.8.012.4300Alt SKU: 653180124300MPN: 65.31.8.012.4300
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 65.31.8.012.4300 Power Relay?

The Finder 65.31.8.012.4300 is a heavy-duty 30 A electromechanical power relay designed for industrial automation, electrical control panels, machinery and high-current switching applications. Part of the Finder 65 Series, this relay combines robust contact performance with a practical flange-mounting arrangement and Faston quick-connect terminals.

Featuring a 12 V AC operating coil and one normally open contact (1 NO / SPST-NO), the Finder 65.31.8.012.4300 enables a low-voltage AC control circuit to operate a separate, higher-current electrical load. Its silver tin oxide (AgSnO₂) contact material is suited to demanding switching applications where contact durability and resistance to welding are important.

With a 30 A rated contact current, 250 V AC rated switching voltage and 7,500 VA AC1 resistive switching capacity, this relay provides substantial switching capability for industrial equipment. The minimum 3 mm open-contact gap and 2,500 V AC dielectric strength between open contacts make the -4300 configuration particularly useful where increased contact separation is required.

The relay is designed for panel mounting using its integrated flange, with 6.3 × 0.8 mm Faston 250 terminals providing convenient electrical connections.

Key Advantages

  • 30 A rated contact current for high-current industrial switching applications.
  • 12 V AC nominal coil for compatible low-voltage AC control circuits.
  • Single normally open contact (SPST-NO) for straightforward load switching.
  • 7,500 VA AC1 switching capacity for appropriately rated resistive loads.
  • 120 A maximum peak current for 5 ms under specified conditions.
  • Silver tin oxide (AgSnO₂) contact material provides robust switching performance.
  • Minimum 3 mm contact gap for increased separation between open contacts.
  • 2,500 V AC dielectric strength between open contacts.
  • Integrated mounting flange supports secure panel installation.
  • Faston 250 quick-connect terminals simplify wiring and maintenance.
  • Monostable operation returns the contact to its open position when the coil is de-energised.
  • Suitable for machinery, industrial electrical equipment and high-current control systems.

Key Features

  • Finder 65 Series industrial power relay.
  • Type 65.31-4300: 30 A flange-mounted relay.
  • 12 V AC operating coil.
  • 50/60 Hz coil operation.
  • One normally open contact (1 NO / SPST-NO).
  • 30 A rated contact current.
  • 120 A maximum peak current for 5 ms under specified conditions.
  • 250 V AC rated switching voltage.
  • 400 V AC maximum switching voltage.
  • 7,500 VA AC1 resistive switching capacity.
  • 1,250 VA AC15 switching capacity at 230 V AC.
  • 1.5 kW single-phase motor rating at 230 V AC.
  • Silver tin oxide (AgSnO₂) contacts.
  • Minimum 3 mm open-contact gap.
  • 2.2 VA rated AC coil consumption at 50 Hz.
  • 4 kV coil-to-contact impulse withstand voltage.
  • Flange mounting for installation onto a suitable panel or mounting surface.
  • Faston 250 terminals measuring 6.3 × 0.8 mm.

30 A High-Current Switching for Industrial Equipment

The Finder 65.31.8.012.4300 operates using an electromagnetic coil that controls a single normally open power contact. When the specified 12 V AC control voltage is applied, the relay energises and closes the contact, allowing current to flow through the connected load. When the coil is de-energised, the contact returns to its normally open position.

This arrangement enables a low-voltage control circuit to switch a separate electrical load without carrying the full load current through the control device. The relay's 30 A rated contact current and 7,500 VA AC1 switching capacity make it suitable for demanding resistive switching duties within the manufacturer's specified limits.

The relay also provides a 120 A peak-current capability for 5 ms on the normally open contact under defined conditions. This short-duration rating is relevant when assessing loads with starting or inrush currents, but it must not be interpreted as a continuous operating current.

For motors, transformers, solenoids and electronic loads, the applicable switching category and actual inrush characteristics must be considered. The relay's resistive AC1 rating cannot automatically be applied to every type of electrical load.

Minimum 3 mm Contact Gap for Enhanced Open-Contact Separation

A distinguishing feature of the Finder 65.31-4300 configuration is its minimum 3 mm contact gap. This provides increased physical separation between the contacts when the relay is de-energised.

The relay is also specified with a 2,500 V AC dielectric strength between open contacts, supporting applications where open-contact insulation performance is an important design consideration.

Although the extended gap is a valuable characteristic, it does not automatically make the relay suitable as a safety isolator or emergency switching device. Any application requiring safety isolation, protective disconnection or compliance with a particular installation standard must be assessed against the complete equipment design and relevant certification requirements.

Flange Mounting and Faston 250 Connections

The Finder 65.31.8.012.4300 features an integrated mounting flange for secure installation onto a suitable panel or mounting surface. This arrangement is particularly useful for industrial equipment where the relay must be mechanically fixed independently of its electrical connections.

The relay uses Faston 250 quick-connect terminals measuring 6.3 × 0.8 mm. These terminals allow compatible push-on connectors to be used for the coil and contact circuits.

When installing the relay, the terminal connectors, conductor sizes and protective devices must be suitable for the intended electrical load. High-current installations require particular attention to connection quality, contact resistance, conductor temperature and enclosure ventilation.

The 12 V AC coil supply must be distinguished from the contact switching voltage. The relay requires a compatible 12 V AC control supply and should not be connected directly to a 12 V DC source unless a different coil version is selected.

Typical Applications

  • Industrial automation and machinery control.
  • High-current electrical load switching.
  • Industrial control panels and electrical equipment.
  • Heating and resistive load control within specified ratings.
  • Single-phase motor switching within the manufacturer's motor rating.
  • Industrial process equipment.
  • OEM machinery and equipment manufacturing.
  • Electrical power distribution control circuits.
  • Building services and HVAC control equipment.
  • Maintenance and replacement in compatible Finder 65 Series installations.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 30 A
Load Voltage 400 V AC
Mounting Type Panel
Manufacturer Finder
Series 65 Series
Manufacturer part number 65.31.8.012.4300
Product type Industrial electromechanical power relay
Relay operation Monostable / non-latching
Number of poles 1
Contact configuration 1 NO (SPST-NO)
Contact material Silver tin oxide (AgSnO₂)
Rated contact current 30 A
Maximum peak contact current 120 A for 5 ms, under specified conditions
Rated switching voltage 250 V AC
Maximum switching voltage 400 V AC
Rated resistive load (AC1) 7,500 VA
Rated inductive load (AC15) 1,250 VA at 230 V AC
Single-phase motor rating 1.5 kW at 230 V AC
DC1 breaking capacity at 24 V DC 30 A
DC1 breaking capacity at 110 V DC 1.1 A
DC1 breaking capacity at 220 V DC 0.7 A
Minimum switching load 1,000 mW (10 V / 10 mA)
Minimum open-contact gap 3 mm
Nominal coil voltage 12 V AC
Coil supply type AC
Coil frequency 50/60 Hz
Rated AC coil consumption 2.2 VA at 50 Hz
Nominal coil current Approximately 183 mA
Nominal coil resistance Approximately 19 Ω
AC coil operating range 80–110% of nominal voltage
Approximate operating voltage range 9.6–13.2 V AC
Operate time 15 ms
Release time 4 ms
Coil-to-contact impulse withstand voltage 4 kV (1.2/50 µs)
Dielectric strength between open contacts 2,500 V AC
Mechanical life 10 million operations
Electrical life at rated AC1 load 30,000 operations
Operating temperature −40 to +75 °C
Environmental protection classification RT I
Mounting type Flange / panel mounting
Terminal type Faston 250 quick-connect
Terminal dimensions 6.3 × 0.8 mm
Number of terminals 4
Approximate overall dimensions 36.5 × 32.2 × 59.2 mm
EAN 8012823461755
Typical application High-current industrial electrical switching

Frequently Asked Questions

What is the Finder 65.31.8.012.4300 used for?

The Finder 65.31.8.012.4300 is a 30 A electromechanical power relay used for industrial automation, machinery control and high-current electrical switching. It features a 12 V AC coil and one normally open contact.

What coil voltage does the Finder 65.31.8.012.4300 require?

The relay requires a 12 V AC nominal coil supply at 50/60 Hz. The specified AC operating range is 80–110% of nominal voltage, equivalent to approximately 9.6–13.2 V AC.

What is the contact configuration of the Finder 65.31.8.012.4300?

The relay has one normally open contact (1 NO / SPST-NO). The contact closes when the coil is energised and opens again when the coil supply is removed. It does not provide a normally closed contact or changeover function.

What does the 3 mm contact gap mean?

The minimum 3 mm contact gap is the physical separation between the open relay contacts. The Finder 65.31-4300 also specifies 2,500 V AC dielectric strength between open contacts. Suitability for a particular isolation requirement must be verified against the applicable electrical standards.

Can the Finder 65.31.8.012.4300 switch 30 A continuously?

The relay has a 30 A rated contact current under specified operating conditions. Actual suitability depends on the load type, switching voltage, duty cycle, terminal connections and installation environment. Its 120 A peak rating for 5 ms is a short-duration capability and must not be treated as a continuous current rating.

Trusted by Industrial Automation and Electrical Engineering Professionals

Finder 65 Series power relays provide robust electromechanical switching solutions for industrial machinery, electrical equipment and high-current control systems. The 65.31-4300 configuration combines 30 A contact capability, extended open-contact separation and convenient flange mounting, supporting electrical engineers, machine builders, panel manufacturers and maintenance professionals.