Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 62.33.9.060.4040 is a 16 A industrial electromechanical power relay featuring a 60 V DC coil, three changeover contacts, silver tin oxide contact material, a lockable test button and mechanical indicator for industrial automation and electrical switching applications.
£13.25
The Finder 62.33.9.060.4040 is a 16 A industrial electromechanical power relay from the Finder 62 Series, designed for reliable switching in industrial automation, machinery control and electrical control panels. Featuring a 60 V DC operating coil and 3 changeover contacts (3 CO / 3PDT), it provides flexible switching of three independent electrical circuits using a single control signal.
The relay incorporates silver tin oxide (AgSnO2) contacts, providing a cadmium-free contact material suitable for appropriately rated electrical loads. Its 16 A nominal contact current, 250 V AC rated contact voltage and 4,000 VA AC-1 switching capacity make it suitable for a range of industrial control and power-switching applications.
The 62.33.9.060.4040 configuration combines a lockable test button with a mechanical indicator, supporting controlled manual testing and visual confirmation of relay operation. Its plug-in construction enables installation using compatible Finder 92 Series sockets, simplifying maintenance and replacement in industrial control assemblies.
The Finder 62.33.9.060.4040 uses an electromagnetic operating mechanism to switch three independent electrical circuits. When its 60 V DC coil is energised, the three changeover contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the contacts return to their normal states, providing dependable non-latching operation.
The lockable test button allows controlled manual actuation during commissioning and maintenance, while the mechanical indicator helps technicians identify the relay's operating position. Its 16 A contact rating and plug-in design make it suitable for maintainable industrial control assemblies. The connected load, switching frequency, socket rating and protective devices must be selected in accordance with the manufacturer's specifications.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Manufacturer | Finder | |
| Series | 62 Series Power Relays | |
| Part number | 62.33.9.060.4040 | |
| Product type | Electromechanical power relay | |
| Contact configuration | 3 CO (3PDT) | |
| Number of poles | 3 | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated load AC-1 | 4,000 VA | |
| Rated load AC-15 at 230 V AC | 750 VA | |
| Single-phase motor rating at 230 V AC | 0.8 kW | |
| Nominal coil voltage | 60 V DC | |
| Coil supply type | DC | |
| Nominal coil current | Approximately 21.7 mA | |
| Coil resistance | Approximately 2,760 Ω | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Relay operating type | Monostable / non-latching | |
| Test button | Lockable | |
| Mechanical indicator | Included | |
| Mounting type | Plug-in / compatible socket mounting | |
| Compatible socket family | Finder 92 Series, subject to socket selection | |
| Electrical life at rated AC-1 load | 100,000 operations | |
| Operating temperature range | −40 to +70 °C | |
| Application | Industrial automation and electrical power switching |
The Finder 62.33.9.060.4040 is a 16 A industrial electromechanical power relay used for switching electrical circuits in automation equipment, machinery controls and industrial control panels.
The relay operates with a nominal 60 V DC coil supply. It is intended for compatible DC control systems and should be connected according to the manufacturer's coil specifications.
The relay features 3 changeover contacts (3 CO / 3PDT), allowing three separate circuits to switch between normally open and normally closed contact paths.
Yes. The 4040 configuration incorporates a lockable test button and mechanical indicator, supporting controlled manual testing and visual confirmation of relay operation.
The relay is designed for plug-in installation using a suitable Finder 92 Series socket. The exact socket should be selected to match the relay's contact arrangement, electrical ratings and mounting requirements.
Finder 62 Series power relays provide practical electrical switching solutions for industrial automation engineers, electrical panel builders and OEM equipment manufacturers requiring reliable multi-circuit control, high-current contacts and convenient maintenance features.
We use cookies