Finder 62.32.9.110.4006 is a 62 Series electromechanical power relay featuring a 110 V DC coil, two 16 A changeover contacts, silver tin oxide contact material, rear flange mounting and Faston 187 quick-connect terminals. Suitable for industrial automation, machinery control and electrical switching applications.
The Finder 62.32.9.110.4006 is a robust 16 A two-pole electromechanical power relay designed for dependable electrical switching in industrial automation, machinery control and electrical control equipment. Part of the established Finder 62 Series, this model combines a 110 V DC operating coil, two changeover contacts and a rear flange mounting arrangement, making it suitable for applications requiring secure mechanical installation.
Featuring a 2 CO (DPDT) contact configuration, the Finder 62.32.9.110.4006 enables two independent electrical circuits to be switched simultaneously using a single control signal. Each changeover contact provides common, normally open and normally closed connections, offering flexibility for electrical interlocking, auxiliary power switching, signalling and industrial control logic. Its silver tin oxide (AgSnO2) contacts provide good resistance to contact welding and support reliable operation with appropriately rated electrical loads.
A distinguishing feature of the Finder 62.32.9.110.4006 is its rear flange mounting configuration, identified by the final digit 6 in the manufacturer part number. This mounting arrangement provides an additional installation option for machinery and industrial equipment. Combined with a 16 A contact rating, 4,000 VA resistive switching capacity, Faston 187 quick-connect terminals and reinforced insulation between coil and contacts, the relay is a practical choice for industrial panel builders, electrical engineers and equipment maintenance professionals.
The Finder 62.32.9.110.4006 uses an electromagnetic switching mechanism to control two independent changeover contacts. When the 110 V DC coil is energised, the internal armature transfers both common contacts from their normally closed positions to their normally open positions. This allows a single DC control signal to switch two separate electrical circuits. When the coil supply is removed, the contacts return automatically to their normal positions, providing conventional monostable operation.
The rear flange mounting arrangement distinguishes this version from the otherwise similar Finder 62.32.9.110.4000. The final digit 6 specifies the rear flange mounting option, while the 4000 version uses the standard mounting configuration. This distinction is important when selecting a replacement relay or designing a mounting arrangement. The relay's Faston 187 terminals support convenient electrical connection, and its reinforced coil-to-contact insulation provides electrical separation between the control circuit and switched loads. Where electronic outputs drive the coil, suitable external transient suppression should be considered because this version does not incorporate a flyback diode.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Manufacturer | Finder | |
| Series | 62 Series Power Relays | |
| Manufacturer part number | 62.32.9.110.4006 | |
| Product type | Electromechanical power relay | |
| Relay configuration | 2 CO / DPDT | |
| Number of poles | 2 | |
| Contact arrangement | Two independent changeover contacts | |
| Nominal coil voltage | 110 V DC | |
| Coil supply type | Direct current (DC) | |
| Coil operating voltage range | 88–121 V DC | |
| Nominal coil resistance | 9,420 Ω | |
| Nominal coil current | 11.7 mA | |
| Nominal coil consumption | Approximately 1.3 W | |
| Relay operating mode | Monostable / non-latching | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated resistive load (AC1) | 4,000 VA | |
| Rated AC15 load at 230 V AC | 750 VA | |
| Single-phase motor rating at 230 V AC | 0.8 kW | |
| DC1 breaking capacity at 24 V DC | 16 A | |
| DC1 breaking capacity at 110 V DC | 0.6 A | |
| DC1 breaking capacity at 220 V DC | 0.4 A | |
| Minimum switching load | 1,000 mW | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Contact material characteristic | Cadmium-free | |
| Mechanical durability | 30 million operations for the DC coil version | |
| Electrical durability at rated AC1 load | 100,000 operations | |
| Typical operating time | 11 ms | |
| Typical release time | 4 ms | |
| Rated impulse withstand voltage between coil and contacts | 6 kV | |
| Dielectric strength between coil and contacts | 4,000 V AC | |
| Dielectric strength between open contacts | 1,500 V AC | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact clearance | 6 mm | |
| Coil-to-contact creepage distance | 8 mm | |
| Operating temperature | −40 to +70 °C | |
| Environmental protection category | RT I | |
| Mounting configuration | Rear flange mount | |
| Terminal type | Faston 187 quick-connect | |
| Terminal dimensions | 4.8 × 0.5 mm | |
| Integrated LED indicator | Not included | |
| Integrated flyback diode | Not included | |
| Manual test button | Not included | |
| Mechanical flag indicator | Not included | |
| Operating principle | Electromagnetic switching | |
| Typical applications | Industrial automation, machinery control, electrical interlocking and auxiliary power switching |
The Finder 62.32.9.110.4006 is a two-pole electromechanical power relay used for switching electrical circuits in industrial automation, machinery control and electrical equipment. Its two changeover contacts allow two independent circuits to be controlled simultaneously using a single 110 V DC control signal. The rear flange mounting arrangement supports secure installation in suitable machinery and control assemblies.
The relay requires a 110 V DC nominal coil supply. Its specified operating voltage range is 88–121 V DC, with a nominal coil current of 11.7 mA and approximately 1.3 W coil consumption. It is designed for DC control circuits and should not be connected directly to a 110 V AC supply.
The relay features a 16 A rated contact current, a 250 V AC rated contact voltage and a 4,000 VA rated resistive switching capacity (AC1). DC switching capacities depend on voltage and load characteristics; for example, the specified DC1 breaking capacity at 110 V DC is 0.6 A.
Both models feature a 110 V DC coil, two 16 A changeover contacts and silver tin oxide contact material. The key difference is the mounting arrangement: the 62.32.9.110.4006 features rear flange mounting, while the 62.32.9.110.4000 is the standard mounting version. The correct model should be selected according to the equipment's mechanical installation requirements.
No. The 62.32.9.110.4006 is supplied without an integrated LED indicator, flyback diode, mechanical flag or manual test button. Its final digit identifies the rear flange mounting option rather than an electronic accessory. Where coil indication or transient suppression is required, an appropriate external solution should be selected.
Finder 62 Series power relays are designed for dependable electrical switching in industrial automation, machinery and electrical control equipment. The Finder 62.32.9.110.4006 combines a 110 V DC operating coil, two 16 A changeover contacts, silver tin oxide contact technology and rear flange mounting, making it a practical choice for electrical engineers, industrial panel builders and machinery maintenance professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.