62.32.9.024.4360 Finder Power relay 2pole 16A DC 24VNO

62.32.9.024.4360 Finder Power relay 2pole 16A DC 24VNO

Finder 62.32.9.024.4360 is a 16 A two-pole normally open electromechanical power relay with a 24 V DC coil, minimum 3 mm contact gap, silver tin oxide contacts, LED indication, integrated suppression diode and Faston 187 terminals for industrial automation and electrical switching.

SKU: 62.32.9.024.4360Alt SKU: 623290244360MPN: 62.32.9.024.4360
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 62.32.9.024.4360 Power Relay?

The Finder 62.32.9.024.4360 is a 16 A two-pole normally open electromechanical power relay designed for industrial automation, electrical control panels and machinery switching applications. Part of the established Finder 62 Series, this relay combines a 24 V DC operating coil with two independent normally open power contacts, providing a practical solution for controlling electrical loads from a common control signal.

Unlike changeover versions of the Finder 62.32 relay, the 62.32.9.024.4360 features two normally open contacts (2NO / DPST-NO). Its contact configuration provides a minimum 3 mm contact gap, making it suitable for applications where the specified contact separation is required. The relay has a 16 A rated contact current, a 250 V AC rated switching voltage and a 4,000 VA AC-1 rated switching capacity.

The .4360 configuration incorporates AgSnO2 silver tin oxide contacts, LED indication and an integrated suppression diode. The LED provides visual confirmation of coil energisation, while the diode helps suppress switching transients from the DC coil. Its Faston 187 terminals allow direct connection or installation using a compatible Finder 92 Series relay socket, supporting practical assembly and replacement in industrial electrical equipment.

Key Advantages

  • Two normally open contacts (2NO / DPST-NO) allow simultaneous switching of two independent electrical circuits.
  • 16 A rated contact current supports appropriately rated industrial power-switching applications.
  • 24 V DC operating coil is suitable for compatible low-voltage industrial control systems.
  • Minimum 3 mm contact gap provides increased contact separation compared with standard changeover configurations.
  • AgSnO2 silver tin oxide contacts provide a cadmium-free contact material with good resistance to electrical wear.
  • Integrated LED indicator provides convenient visual confirmation of coil energisation.
  • Built-in suppression diode helps protect compatible DC control circuits against coil switching transients.
  • Faston 187 terminals support direct electrical connection or installation with a suitable socket.
  • Monostable electromagnetic operation ensures both contacts return to their normally open state when the coil is de-energised.
  • 4,000 VA AC-1 switching capacity supports appropriately rated resistive electrical loads.
  • Established Finder 62 Series construction supports industrial automation and machinery control applications.
  • Suitable for replacement of compatible Finder 62.32 normally open relay configurations.

Key Features

  • Finder 62 Series industrial electromechanical power relay.
  • Two normally open contacts (2NO / DPST-NO / 2 Form A).
  • 16 A rated contact current.
  • 24 V DC nominal coil voltage.
  • 250 V AC rated switching voltage.
  • 400 V AC maximum switching voltage.
  • 4,000 VA rated AC-1 switching capacity.
  • Minimum 3 mm contact gap.
  • AgSnO2 silver tin oxide contact material.
  • Cadmium-free contact construction.
  • Integrated LED coil-status indication.
  • Integrated DC coil suppression diode.
  • Polarity-sensitive DC coil connection.
  • Monostable, non-latching electromagnetic operation.
  • Faston 187 terminals measuring 4.8 × 0.5 mm.
  • Socket mounting with compatible Finder 92 Series accessories.
  • Suitable for industrial control panels, automation and auxiliary power switching.
  • .4360 manufacturer variant designation.

Reliable Two-Pole Switching with LED Indication and Coil Protection

The Finder 62.32.9.024.4360 operates through an electromagnetic switching mechanism controlled by a 24 V DC coil. When the coil is energised, both normally open contacts close, allowing current to flow through their respective load circuits. When coil power is removed, the monostable mechanism returns both contacts to their open positions.

The two normally open contact arrangement is particularly useful where two circuits must be energised together without requiring changeover contacts. The minimum 3 mm contact gap is a distinguishing feature of the 62.32-4300 configuration. Applications requiring a particular disconnection function must still be assessed against the relevant electrical standards and complete installation design.

The relay incorporates AgSnO2 silver tin oxide contacts, providing a cadmium-free contact material suitable for appropriately rated industrial switching duties. Its 16 A contact rating and 4,000 VA AC-1 switching capacity support resistive load applications, while inductive loads, motors and equipment with high inrush currents require additional consideration of the relevant switching ratings.

The integrated LED provides a visual indication of coil energisation, helping engineers identify the relay's commanded operating condition during commissioning and maintenance. The suppression diode reduces the voltage transient generated when the DC coil is switched off. Because the diode is polarity-sensitive, the coil must be connected according to the manufacturer's designated positive and negative terminals.

For installation, the relay uses Faston 187 quick-connect terminals and can be fitted into a compatible Finder 92 Series socket. Correct socket selection, contact loading, coil polarity and electrical protection are essential. The complete 62.32.9.024.4360 reference should be checked when replacing another relay, particularly because changeover and normally open Finder 62.32 variants are not electrically interchangeable.

Typical Applications

  • Industrial automation and electrical control panels.
  • 24 V DC control systems.
  • Programmable logic controller (PLC) output interfacing.
  • Manufacturing machinery and production equipment.
  • Two-pole normally open power switching.
  • Auxiliary electrical control circuits.
  • Equipment sequencing and industrial interlocking.
  • Lighting control and appropriately rated lighting circuits.
  • Heating, ventilation and air conditioning controls.
  • Industrial signalling and monitoring equipment.
  • OEM machinery and electrical equipment manufacture.
  • Control panels requiring LED relay-status indication.
  • DC control circuits requiring integrated coil suppression.
  • Replacement of compatible Finder 62.32-4300 relay variants.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Load Voltage 250 V AC
Switching Current (A) 16 A
Manufacturer Finder
Series 62 Series Power Relays
Manufacturer part number 62.32.9.024.4360
Product type Electromechanical power relay
Relay configuration 62.32-4300 family
Contact arrangement 2NO / DPST-NO / 2 Form A
Number of poles 2
Rated contact current 16 A
Maximum peak contact current 120 A for 5 ms, under specified conditions
Rated switching voltage 250 V AC
Maximum AC switching voltage 400 V AC
Rated AC-1 switching capacity 4,000 VA
Rated AC-15 switching capacity 750 VA at 230 V AC
Contact gap ≥ 3 mm
Contact material AgSnO2 (silver tin oxide)
Nominal coil voltage 24 V DC
Coil supply type DC
Nominal coil current 125 mA
Nominal coil power 3 W
Coil resistance 192 Ω
Must-operate voltage 20.4 V DC
Must-release voltage 4.8 V DC
Coil suppression Integrated diode
Electrical indication LED
Operating principle Monostable electromagnetic
Operating temperature range −40 to +70 °C
Terminal type Faston 187 quick-connect
Terminal dimensions 4.8 × 0.5 mm
Mounting arrangement Socket-mounted or direct Faston connection
Compatible socket family Finder 92 Series, suitable models
Manufacturer variant .4360

Frequently Asked Questions

What is the Finder 62.32.9.024.4360 used for?

The Finder 62.32.9.024.4360 is a two-pole normally open electromechanical power relay used for industrial automation, machinery control and auxiliary electrical switching. It allows two independent circuits to be switched using one 24 V DC control coil.

What coil voltage does the Finder 62.32.9.024.4360 require?

The relay requires a nominal 24 V DC coil supply. Its integrated LED and suppression diode make the coil connection polarity-sensitive, so the manufacturer's terminal markings must be followed.

Does the Finder 62.32.9.024.4360 have changeover contacts?

No. This model has two normally open contacts (2NO / DPST-NO), rather than two changeover contacts. Both contacts close when the coil is energised and reopen when coil power is removed.

What is the rated contact current of this relay?

The Finder 62.32.9.024.4360 has a 16 A rated contact current, with a standard 250 V AC rated switching voltage and 4,000 VA AC-1 switching capacity. Actual permissible loading depends on the application and connected load characteristics.

What does the .4360 suffix identify?

The .4360 variant combines the two normally open contact configuration with AgSnO2 silver tin oxide contacts, LED indication and an integrated suppression diode. The normally open contact design provides a minimum 3 mm contact gap.

Does the Finder 62.32.9.024.4360 have an integrated diode?

Yes. The relay includes a coil suppression diode that helps reduce voltage transients when the 24 V DC coil is de-energised. Correct coil polarity is essential for safe operation.

How is the Finder 62.32.9.024.4360 mounted?

The relay uses Faston 187 terminals measuring 4.8 × 0.5 mm and supports direct Faston connection or installation with a suitable Finder 92 Series socket. Socket compatibility and electrical ratings must be confirmed before installation.

Can this relay replace the Finder 62.32.9.024.0360?

The 62.32.9.024.4360 is listed as a manufacturer-recommended substitute for the discontinued 62.32.9.024.0360. The contact configuration, terminal arrangement and complete installation requirements should still be checked before replacement.

Trusted by Industrial Automation Professionals Worldwide

Finder 62 Series power relays provide practical electromagnetic switching for industrial automation, machinery control and electrical installations. Their robust contact construction, flexible mounting arrangements and integrated indication and suppression options support reliable operation and straightforward maintenance in industrial control equipment.