Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 62.32.9.006.4040 is a 16 A electromechanical power relay featuring a 6 V DC coil, two changeover contacts, silver tin oxide contact material, Faston 187 terminals, a lockable test button and a mechanical indicator for industrial automation and electrical switching applications.
The Finder 62.32.9.006.4040 is a 16 A industrial electromechanical power relay designed for reliable electrical switching in automation systems, machinery control and industrial electrical installations. Part of the established Finder 62 Series, this relay features 2 changeover contacts (2 CO / DPDT), a 6 V DC operating coil and a plug-in connection arrangement suitable for industrial control equipment.
The Finder 62.32 relay design combines dependable switching performance with convenient installation and maintenance. Its Faston 187 terminals allow direct connections or installation using compatible Finder 92 Series sockets. The silver tin oxide (AgSnO2) contact material provides a cadmium-free switching solution for appropriately rated industrial electrical loads.
The 62.32.9.006.4040 configuration also incorporates a lockable test button and mechanical indicator, providing a practical means of checking relay operation and identifying contact status during commissioning and maintenance. Its 16 A contact rating and 6 V DC coil make it suitable for applications requiring a low-voltage DC control signal to operate higher-power electrical circuits.
The Finder 62.32.9.006.4040 uses an electromagnetic switching mechanism to control two independent electrical circuits. When the 6 V DC coil is energised, both changeover contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the contacts return to their normal states, providing dependable non-latching operation.
Its lockable test button and mechanical indicator are useful during equipment commissioning, inspection and troubleshooting. The plug-in Faston construction also makes the relay suitable for maintainable industrial control assemblies. Electrical loads must remain within the applicable contact ratings, and manual testing should only be undertaken under appropriate safe working conditions.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Mounting Type | Plug-in socket | |
| Manufacturer | Finder | |
| Series | 62 Series | |
| Part number | 62.32.9.006.4040 | |
| Product type | Electromechanical power relay | |
| Contact configuration | 2 CO (DPDT) | |
| Number of poles | 2 | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Nominal coil voltage | 6 V DC | |
| Coil supply type | DC | |
| DC coil operating voltage range | 4.8–6.6 V DC | |
| Nominal coil current | approximately 214 mA | |
| Coil resistance | approximately 28 Ω | |
| Nominal coil power | approximately 1.3 W | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Relay operating type | Monostable / non-latching | |
| Test button | Lockable | |
| Mechanical indicator | Included | |
| Mounting type | Plug-in / compatible socket mounting | |
| Connection type | Faston 187 terminals | |
| Terminal dimensions | 4.8 × 0.5 mm | |
| Compatible socket family | Finder 92 Series, subject to socket selection | |
| Insulation between coil and contacts | Reinforced | |
| Application | Industrial automation and electrical power switching |
The Finder 62.32.9.006.4040 is a 16 A industrial power relay used for switching electrical circuits in automation equipment, machinery controls, lighting systems and industrial control panels.
The relay requires a nominal 6 V DC coil supply. Its specified DC coil operating range is approximately 4.8–6.6 V DC.
The relay features 2 changeover contacts (2 CO / DPDT), allowing two separate circuits to switch between normally open and normally closed contact positions.
Yes. The 4040 configuration includes a lockable test button and mechanical indicator, allowing manual testing and visual confirmation of relay operation during appropriate maintenance procedures.
The relay uses Faston 187 terminals measuring 4.8 × 0.5 mm and can be installed with a suitable Finder 92 Series socket. The exact socket should be selected according to the relay configuration and installation requirements.
Finder 62 Series power relays provide dependable electrical switching solutions for industrial automation engineers, electrical panel builders and OEM equipment manufacturers requiring robust contact ratings, flexible circuit control and convenient maintenance features.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.