62.32.9.006.4040 Finder Power relay 2pole 16A DC 6VNO

62.32.9.006.4040 Finder Power relay 2pole 16A DC 6VNO

Finder 62.32.9.006.4040 is a 16 A electromechanical power relay featuring a 6 V DC coil, two changeover contacts, silver tin oxide contact material, Faston 187 terminals, a lockable test button and a mechanical indicator for industrial automation and electrical switching applications.

SKU: 62.32.9.006.4040Alt SKU: 623290064040MPN: 62.32.9.006.4040
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 62.32.9.006.4040 Power Relay?

The Finder 62.32.9.006.4040 is a 16 A industrial electromechanical power relay designed for reliable electrical switching in automation systems, machinery control and industrial electrical installations. Part of the established Finder 62 Series, this relay features 2 changeover contacts (2 CO / DPDT), a 6 V DC operating coil and a plug-in connection arrangement suitable for industrial control equipment.

The Finder 62.32 relay design combines dependable switching performance with convenient installation and maintenance. Its Faston 187 terminals allow direct connections or installation using compatible Finder 92 Series sockets. The silver tin oxide (AgSnO2) contact material provides a cadmium-free switching solution for appropriately rated industrial electrical loads.

The 62.32.9.006.4040 configuration also incorporates a lockable test button and mechanical indicator, providing a practical means of checking relay operation and identifying contact status during commissioning and maintenance. Its 16 A contact rating and 6 V DC coil make it suitable for applications requiring a low-voltage DC control signal to operate higher-power electrical circuits.

Key Advantages

  • 16 A contact rating for industrial electrical switching applications.
  • 2 changeover contacts (DPDT) provide flexible control of two independent circuits.
  • 6 V DC coil supports compatible low-voltage DC control systems.
  • Lockable test button allows manual relay operation during appropriate testing and commissioning procedures.
  • Mechanical indicator provides a visual indication of relay operation.
  • Silver tin oxide (AgSnO2) contacts provide a cadmium-free contact material.
  • Faston 187 plug-in terminals support straightforward installation and replacement.
  • Compatible with suitable Finder 92 Series relay sockets.

Key Features

  • Finder 62 Series industrial power relay.
  • 2 CO (DPDT) contact configuration.
  • 16 A nominal contact current.
  • 6 V DC nominal coil voltage.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • Silver tin oxide (AgSnO2) contact material.
  • Lockable test button for manual contact actuation.
  • Mechanical flag indicator for visual monitoring.
  • Faston 187 terminals measuring 4.8 × 0.5 mm.
  • Plug-in installation with compatible Finder 92 Series sockets.
  • Monostable, non-latching electromagnetic operation.
  • Reinforced insulation between coil and contacts.
  • Suitable for electrical control panels, industrial automation and OEM equipment.

Reliable Power Switching for Industrial Automation

The Finder 62.32.9.006.4040 uses an electromagnetic switching mechanism to control two independent electrical circuits. When the 6 V DC coil is energised, both changeover contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the contacts return to their normal states, providing dependable non-latching operation.

Its lockable test button and mechanical indicator are useful during equipment commissioning, inspection and troubleshooting. The plug-in Faston construction also makes the relay suitable for maintainable industrial control assemblies. Electrical loads must remain within the applicable contact ratings, and manual testing should only be undertaken under appropriate safe working conditions.

Typical Applications

  • Industrial automation and machinery control systems.
  • Low-voltage DC-operated relay control circuits.
  • Electrical control panels and automation cabinets.
  • Motor starter auxiliary control and interlocking circuits.
  • Industrial and commercial lighting control.
  • Heating and temperature control equipment.
  • Electrical signalling and auxiliary switching systems.
  • OEM machinery and industrial equipment assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 16 A
Load Voltage 400 V AC
Mounting Type Plug-in socket
Manufacturer Finder
Series 62 Series
Part number 62.32.9.006.4040
Product type Electromechanical power relay
Contact configuration 2 CO (DPDT)
Number of poles 2
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Nominal coil voltage 6 V DC
Coil supply type DC
DC coil operating voltage range 4.8–6.6 V DC
Nominal coil current approximately 214 mA
Coil resistance approximately 28 Ω
Nominal coil power approximately 1.3 W
Contact material Silver tin oxide (AgSnO2)
Relay operating type Monostable / non-latching
Test button Lockable
Mechanical indicator Included
Mounting type Plug-in / compatible socket mounting
Connection type Faston 187 terminals
Terminal dimensions 4.8 × 0.5 mm
Compatible socket family Finder 92 Series, subject to socket selection
Insulation between coil and contacts Reinforced
Application Industrial automation and electrical power switching

Frequently Asked Questions

What is the Finder 62.32.9.006.4040 used for?

The Finder 62.32.9.006.4040 is a 16 A industrial power relay used for switching electrical circuits in automation equipment, machinery controls, lighting systems and industrial control panels.

What coil voltage does the Finder 62.32.9.006.4040 require?

The relay requires a nominal 6 V DC coil supply. Its specified DC coil operating range is approximately 4.8–6.6 V DC.

What is the contact configuration of this Finder relay?

The relay features 2 changeover contacts (2 CO / DPDT), allowing two separate circuits to switch between normally open and normally closed contact positions.

Does the Finder 62.32.9.006.4040 have a test button?

Yes. The 4040 configuration includes a lockable test button and mechanical indicator, allowing manual testing and visual confirmation of relay operation during appropriate maintenance procedures.

Which sockets are compatible with the Finder 62.32.9.006.4040?

The relay uses Faston 187 terminals measuring 4.8 × 0.5 mm and can be installed with a suitable Finder 92 Series socket. The exact socket should be selected according to the relay configuration and installation requirements.

Trusted by Industrial Automation Professionals Worldwide

Finder 62 Series power relays provide dependable electrical switching solutions for industrial automation engineers, electrical panel builders and OEM equipment manufacturers requiring robust contact ratings, flexible circuit control and convenient maintenance features.