62.32.8.110.0056 Finder Power relay 2pole 16A 110V

62.32.8.110.0056 Finder Power relay 2pole 16A 110V

Finder 62.32.8.110.0056 is a 16 A DPDT electromagnetic power relay with a 110 V AC coil, lockable test button, LED indicator and rear mounting flange for industrial control applications.

SKU: 62.32.8.110.0056Alt SKU: 623281100056MPN: 62.32.8.110.0056
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 62.32.8.110.0056 Power Relay?

The Finder 62.32.8.110.0056 is a robust DPDT electromagnetic power relay designed for switching high-current electrical loads in industrial automation, machinery and control-panel applications. Part of the proven Finder 62 Series, it combines two changeover contacts with a compact plug-in design and rear mounting flange.

This relay features a lockable test button and AC LED indicator, allowing convenient manual testing and clear visual confirmation of coil energisation during installation, commissioning and maintenance. Its AgCdO contacts provide dependable switching performance, while Faston 187 terminals support secure and efficient electrical connections.

With a 110 V AC coil, two changeover contacts and a rated contact current of 16 A, the Finder 62.32.8.110.0056 is suitable for controlling motors, contactors, heaters, lighting circuits and other industrial loads. The integrated rear flange enables direct mounting where a relay socket is not required.

Key Advantages

  • High-capacity 16 A power relay for industrial switching.
  • Two changeover contacts provide flexible DPDT circuit control.
  • 110 V AC coil suitable for industrial control systems.
  • Lockable test button supports convenient commissioning and maintenance.
  • Integrated LED provides visual indication when the AC coil is energised.
  • Rear mounting flange enables secure direct installation.

Key Features

  • Finder 62 Series electromagnetic power relay.
  • 2 CO (DPDT) contact configuration.
  • 16 A rated contact current.
  • 110 V AC, 50/60 Hz coil.
  • AgCdO contact material.
  • Lockable test button and AC LED indicator.
  • Rear flange for direct mounting.
  • Plug-in Faston 187 terminals measuring 4.8 × 0.5 mm.

Reliable Switching for Industrial Control Systems

Electromagnetic power relays such as the Finder 62.32 provide electrical isolation between the control circuit and switched loads. Energising the coil changes the state of both changeover contacts, allowing one control signal to operate multiple circuits or switch between normally open and normally closed paths.

The integrated test button helps technicians verify circuit operation without applying an external control signal, while the LED clearly displays the coil state. Rear-flange mounting and Faston terminals make this variant particularly useful for machinery, equipment assemblies and control cabinets requiring direct, secure installation.

Typical Applications

  • Industrial machinery and automation systems.
  • Electrical control panels and switchgear.
  • Motor, contactor and solenoid control circuits.
  • Heating and lighting control equipment.
  • Pumps, fans and ventilation systems.
  • OEM equipment and machine building.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 16 A
Load Voltage 400 V AC
Mounting Type Plug-in socket
Coil / Supply Voltage 110 V AC
Contacts 2 C/O
HS Code 85364900
Manufacturer Finder
Series 62 Series
Model 62.32.8.110.0056
Product type Electromagnetic power relay
Contact configuration 2 CO (DPDT)
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated load, AC1 4,000 VA
Contact material AgCdO
Coil voltage 110 V AC
Coil frequency 50/60 Hz
Coil current 20 mA
Coil power 2.2 VA
Coil resistance 1.6 kΩ
Operating voltage range 88–121 V AC
Coil-to-contact impulse withstand voltage 6 kV
Operate time 11 ms
Release time 4 ms
Terminals Faston 187, 4.8 × 0.5 mm
Mounting type Plug-in or direct rear-flange mounting
Indicators and controls AC LED and lockable test button

Frequently Asked Questions

What is the Finder 62.32.8.110.0056 used for?

This power relay is used to switch electrical loads in industrial machinery, automation equipment and control-panel applications.

What contact configuration does this relay have?

The relay has two changeover contacts, providing a DPDT contact configuration rated at 16 A.

What coil voltage does the relay require?

The Finder 62.32.8.110.0056 uses a 110 V AC, 50/60 Hz coil.

Does this relay include an indicator and test button?

Yes. It includes an AC LED indicator and lockable test button for visual status indication and manual testing.

How is the Finder 62.32.8.110.0056 mounted?

The relay can be connected through its Faston 187 terminals and secured directly using its integrated rear mounting flange.

Trusted Industrial Relay Technology

Finder 62 Series power relays are widely used by control-panel builders, automation engineers and equipment manufacturers for dependable high-current switching in industrial electrical systems.