62.32.8.110.0030 Finder Power relay 2pole 16A 110V

62.32.8.110.0030 Finder Power relay 2pole 16A 110V

Finder 62.32.8.110.0030 is a plug-in electromagnetic power relay with a 110 V AC coil, two 16 A changeover contacts and an integrated LED status indicator.

SKU: 62.32.8.110.0030Alt SKU: 623281100030MPN: 62.32.8.110.0030
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 62.32.8.110.0030 Power Relay?

The Finder 62.32.8.110.0030 is a robust plug-in electromagnetic power relay designed for dependable switching in industrial control, automation and electrical equipment. Part of the Finder 62 Series, it combines a 110 V AC coil with two changeover contacts, each rated at 16 A.

Its DPDT contact configuration provides two independently switched normally open and normally closed circuits, offering flexibility for controlling multiple loads or functions. The relay uses durable AgCdO contact material and provides reinforced insulation between the coil and contact circuits.

The 62.32.8.110.0030 includes an integrated LED indicator for the AC coil, providing clear visual confirmation when the relay is energised. Its plug-in format and 4.8 × 0.5 mm Faston terminals enable straightforward installation in compatible sockets and industrial control assemblies.

Key Advantages

  • Heavy-duty power relay for industrial switching applications.
  • Two changeover contacts rated at 16 A.
  • 110 V AC coil for compatible control circuits.
  • Integrated AC LED indicator provides visible coil-status indication.
  • AgCdO contact material supports dependable load switching.
  • Plug-in construction supports convenient installation and replacement.

Key Features

  • Finder 62 Series power relay.
  • 110 V AC nominal coil voltage.
  • DPDT / 2 CO contact configuration.
  • 16 A rated contact current.
  • 250 V AC rated contact voltage.
  • AgCdO contact material.
  • 1.6 kΩ coil resistance.
  • Integrated LED indicator for AC coil operation.
  • Plug-in mounting with Faston terminals.

Visible Status for Industrial Power Switching

Power relays allow a control circuit to operate electrically isolated loads without carrying the load current through the controlling device. Applying 110 V AC to the coil of the Finder 62.32.8.110.0030 transfers both changeover contacts between their normally closed and normally open circuits.

The integrated LED illuminates when the coil is energised, allowing engineers to check the relay’s control status quickly during operation, commissioning and fault diagnosis. Its two 16 A changeover contacts provide flexible switching for industrial equipment and control panels.

Typical Applications

  • Industrial machinery and automation systems.
  • Electrical control panels and switchgear.
  • Heating, ventilation and air-conditioning equipment.
  • Pumps, motors and auxiliary load controls.
  • Lighting and building automation systems.
  • Industrial ovens, furnaces and process equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Terminal Type Faston / flat-pin
Switching Current (A) 16 A
Load Voltage 400 V AC
Mounting Type Plug-in socket
Coil / Supply Voltage 110 V AC
Contacts 2 C/O
HS Code 85364900
Manufacturer Finder
Series 62 Series
Model 62.32.8.110.0030
Product type Electromagnetic power relay
Coil voltage 110 V AC, 50 / 60 Hz
Coil resistance 1.6 kΩ
Rated coil consumption 2.2 VA
Rated coil current 20 mA
Coil operating range 88–121 V AC
Contact configuration 2 changeover contacts (DPDT / 2 CO)
Rated contact current 16 A
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated load AC1 4,000 VA
Rated load AC15 at 230 V AC 750 VA
Contact material AgCdO
Indicator LED for AC coil
Coil-to-contact isolation 6 kV impulse withstand voltage
Operate time 11 ms
Release time 4 ms
Operating type Monostable
Mounting type Plug-in / direct Faston connection
Compatible socket series Finder 92 Series
Terminal type Faston connectors
Terminal dimensions 4.8 × 0.5 mm
Ambient temperature range −40 to +70 °C
Dimensions 35.8 × 38.2 × 49.1 mm

Frequently Asked Questions

What is the Finder 62.32.8.110.0030 used for?

This power relay switches electrical loads in industrial machinery, control panels, building automation and process equipment.

What coil voltage does this relay require?

The Finder 62.32.8.110.0030 operates from a nominal 110 V AC coil supply.

What contact configuration does the relay have?

It has two DPDT changeover contacts, providing two sets of normally open, normally closed and common connections.

What is the contact current rating?

Each changeover contact has a rated current of 16 A.

Does this relay include a status indicator?

Yes. It has an integrated LED indicator for the AC coil, which provides visual confirmation when the relay is energised.

Trusted Finder Power Relay Technology

Finder 62 Series power relays are widely used in industrial control and automation systems where high-capacity switching and clear operating-status indication are required.