Finder 62.32.8.048.4040 is a 62 Series plug-in electromechanical power relay featuring a 48 V AC coil, two 16 A changeover contacts, silver tin oxide contact material, Faston 187 terminals, a lockable test button and a mechanical flag indicator for industrial automation and electrical control applications.
The Finder 62.32.8.048.4040 is a robust 16 A two-pole electromechanical power relay designed for dependable electrical switching in industrial automation, machinery control and electrical control panels. Part of the established Finder 62 Series, this relay features a 48 V AC operating coil, two changeover contacts and a plug-in mounting arrangement for convenient integration into industrial electrical systems.
Featuring a 2 CO (DPDT) contact configuration, the relay enables two independent circuits to be switched simultaneously using a single control signal. Each contact provides common, normally open and normally closed connections, making the relay suitable for electrical interlocking, control logic and auxiliary switching. Its silver tin oxide (AgSnO2) contacts provide good resistance to contact welding and support reliable operation with appropriately rated industrial loads.
A distinguishing feature of the 62.32.8.048.4040 is its lockable test button and mechanical flag indicator. The test button allows technicians to operate the contacts manually during commissioning and maintenance, while the mechanical flag provides a visual indication of relay operation. Combined with Faston 187 quick-connect terminals and compatibility with appropriately selected Finder 92 Series sockets, this model offers a practical solution for industrial control installations requiring reliable switching and convenient maintenance access.
The Finder 62.32.8.048.4040 operates through an electromagnetic switching mechanism. When the 48 V AC coil is energised, the internal armature transfers both changeover contacts from their normal positions to their operated positions. Each pole can therefore switch between a normally closed and a normally open circuit. When the coil is de-energised, the relay returns to its normal contact state.
The integrated lockable test button and mechanical flag indicator make this version particularly useful in industrial control panels where commissioning, fault-finding and routine maintenance are important. Technicians can manually operate the relay contacts using the test button and observe the mechanical indication without relying solely on external monitoring equipment. When installed in a suitable Finder 92 Series socket, the relay can also be replaced without desoldering or modifying a printed circuit board. Manual testing should only be carried out by competent personnel using appropriate electrical safety procedures.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | Faston / flat-pin | |
| Load Voltage | 400 V AC | |
| Mounting Type | Plug-in socket | |
| Switching Current (A) | 16 A | |
| Manufacturer | Finder | |
| Series | 62 Series Power Relays | |
| Manufacturer part number | 62.32.8.048.4040 | |
| Product type | Electromechanical power relay | |
| Relay configuration | 2 CO / DPDT | |
| Number of poles | 2 | |
| Contact arrangement | Two independent changeover contacts | |
| Nominal coil voltage | 48 V AC | |
| Coil supply type | Alternating current (AC) | |
| Coil frequency | 50/60 Hz | |
| Operating principle | Electromagnetic | |
| Relay operating mode | Monostable / non-latching | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated resistive load (AC1) | 4,000 VA | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Coil-to-contact insulation | Reinforced | |
| Coil-to-contact clearance | 6 mm | |
| Coil-to-contact creepage distance | 8 mm | |
| Rated impulse withstand voltage between coil and contacts | 6 kV | |
| Manual test function | Lockable test button | |
| Contact operation indication | Mechanical flag indicator | |
| Mounting type | Plug-in / quick-connect | |
| Terminal type | Faston 187 | |
| Terminal dimensions | 4.8 × 0.5 mm | |
| Compatible socket family | Finder 92 Series, subject to socket selection | |
| Typical applications | Industrial control panels, machinery control, automation and auxiliary electrical switching |
The Finder 62.32.8.048.4040 is a two-pole electromechanical power relay used for switching electrical circuits in industrial automation, machinery control and electrical panels. Its two changeover contacts allow two independent circuits to be controlled simultaneously, while its lockable test button and mechanical flag support commissioning and maintenance.
The relay requires a 48 V AC nominal coil supply operating at 50/60 Hz. It is designed for compatible alternating-current control circuits and should not be substituted directly for a 48 V DC relay.
Both models belong to the Finder 62 Series and feature a 48 V AC coil and two changeover contacts. The 62.32.8.048.4040 additionally includes a lockable test button and mechanical flag indicator, while the 62.32.8.048.4000 is the standard version without these additional manual testing and indication features.
The lockable test button allows the relay contacts to be operated manually for testing and commissioning. The button can provide momentary operation and, when configured according to Finder's instructions, can be locked in the operated position. The mechanical flag provides visual indication of relay operation. Manual operation should be performed only under suitable electrical safety conditions.
The relay uses Faston 187 quick-connect terminals measuring 4.8 × 0.5 mm and can be installed with a suitably selected Finder 92 Series socket. This arrangement supports installation in industrial electrical control panels and allows convenient relay replacement during maintenance.
Finder 62 Series power relays are designed for dependable electrical switching in industrial automation, machinery and control equipment. The Finder 62.32.8.048.4040 combines a 48 V AC coil, two 16 A changeover contacts, silver tin oxide contact technology, a lockable test button and a mechanical flag indicator, making it a practical solution for electrical engineers, industrial panel builders and maintenance professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.