62.32.8.024.4054 Finder Power relay 2pole 16A 24V.
The Finder 62.32.8.024.4054 is a 16 A industrial electromechanical power relay from the established Finder 62 Series. Featuring a 24 V AC operating coil and two changeover contacts (DPDT / 2 CO), the relay is designed for electrical control applications requiring two independent switching circuits to operate from a single control signal.
The Finder 62.32 relay family combines high-current switching capability with a practical plug-in construction, making it suitable for industrial machinery, automation systems, electrical control panels and building services equipment. Its 16 A contact rating and 400 V AC maximum switching voltage provide flexibility for suitably rated electrical loads, subject to the applicable switching category and installation requirements.
The exact 62.32.8.024.4054 suffix configuration should be checked against Finder's original ordering documentation before installation or substitution. The core relay designation identifies a two-pole changeover relay with a 24 V AC coil, while the final digits distinguish its specific contact, mechanical or optional equipment configuration. This makes exact part-number matching particularly important for replacement applications.
The Finder 62.32.8.024.4054 uses an electromagnetic coil to operate two changeover contacts. When the 24 V AC coil is energised, both contacts transfer from their normally closed positions to their normally open positions. When the coil is de-energised, the contacts return to their original positions.
This DPDT relay arrangement is useful for applications where two electrical circuits must respond to the same control signal. It can support auxiliary switching, electrical interlocking, equipment status changes and other control functions, while reducing the need for multiple individual relays.
The plug-in construction of the Finder 62.32 family is particularly useful in maintenance environments, allowing a relay to be removed from a compatible socket without disconnecting every field wire. Before replacement, engineers should compare the complete part number, coil supply, contact configuration, socket pinout and any special suffix features. Relays sharing the same 62.32 base designation are not necessarily interchangeable in every installation.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Switching Current (A) | 16 A | |
| Manufacturer | Finder | |
| Series | 62 Series | |
| Manufacturer part number | 62.32.8.024.4054 | |
| Base relay designation | 62.32 | |
| Product category | Industrial electromechanical power relay | |
| Contact configuration | 2 changeover (2 CO / DPDT) | |
| Number of poles | 2 | |
| Nominal coil voltage | 24 V AC | |
| Coil frequency | 50/60 Hz | |
| Coil operating principle | Monostable / non-latching | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum AC switching voltage | 400 V AC | |
| Nominal coil resistance | 74 Ω for the standard 24 V AC 62.32 coil | |
| Nominal coil current | 90 mA for the standard 24 V AC 62.32 coil | |
| Standard coil operating range | 19.2 to 26.4 V AC | |
| Typical operate time | 11 ms for standard 62.32 versions | |
| Typical release time | 4 ms for standard 62.32 versions | |
| Standard operating temperature range | −40 to +70 °C | |
| Mounting method | Plug-in / compatible relay socket | |
| Connection style | Quick-connect relay terminals | |
| Nominal terminal format | Faston 187, approximately 4.8 mm | |
| Contact material | Exact .4054 suffix specification requires confirmation | |
| Optional indication or test facilities | Exact .4054 suffix specification requires confirmation | |
| Environmental and regulatory approvals | Verify against documentation for the exact part number |
The Finder 62.32.8.024.4054 is an industrial electromechanical power relay used to switch electrical circuits in automation systems, machinery and control panels. It belongs to the Finder 62 Series and has a 24 V AC coil and two changeover contacts.
The part number identifies a 24 V AC coil, not a 24 V DC coil. Standard Finder 62.32 AC versions operate at 50/60 Hz. The correct supply must be used to avoid relay malfunction or damage.
DPDT stands for double-pole double-throw. The relay has two changeover contacts, each providing a common terminal, a normally open connection and a normally closed connection. Both contacts are operated together by the same coil.
The Finder 62.32 relay family has a 16 A rated contact current and 250 V AC rated contact voltage, with a maximum AC switching voltage of 400 V AC. Actual permissible switching loads depend on their electrical characteristics and the specific relay variant.
Not automatically. Although Finder 62.32 relays share a common two-pole changeover design, different part-number suffixes can identify different contact materials, indicators, test facilities or other construction details. Confirm the complete part number, 24 V AC coil, contact arrangement and socket compatibility before selecting a replacement.
Finder 62 Series power relays provide practical multi-pole switching solutions for industrial machinery, automation equipment and electrical control panels. The Finder 62.32.8.024.4054 combines a 24 V AC coil, two 16 A changeover contacts and plug-in relay construction for professional electrical control applications where the correct variant and installation requirements are verified.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.