Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 62.23.9.060.4000 is a 62 Series PCB-mounted electromechanical power relay featuring a 60 V DC coil, three 16 A changeover contacts, silver tin oxide contact material and reinforced coil-to-contact insulation for industrial automation, machinery control and electrical switching applications.
£13.76
The Finder 62.23.9.060.4000 is a robust 16 A three-pole electromechanical power relay designed for dependable switching in industrial automation, machinery control and electronic equipment. Part of the established Finder 62 Series power relay range, this model combines a 60 V DC operating coil, three changeover contacts and durable silver tin oxide contact technology for reliable operation in industrial electrical systems.
Featuring a 3PDT (three-pole double-throw) contact configuration, the relay allows three independent electrical circuits to be switched simultaneously using a single control signal. Each changeover contact provides a common, normally open and normally closed connection, making the relay suitable for control logic, electrical interlocking and auxiliary switching applications. Its silver tin oxide (AgSnO2) contacts provide good resistance to contact welding and support dependable switching of suitable industrial loads.
With a 16 A rated contact current, 250 V AC rated contact voltage and 60 V DC nominal coil voltage, the Finder 62.23.9.060.4000 is suitable for industrial control equipment, machinery automation and power switching assemblies. Its printed circuit board mounting arrangement enables direct integration into electronic control systems, while reinforced insulation between the coil and contacts supports electrical separation within industrial equipment.
Electromechanical power relays such as the Finder 62.23.9.060.4000 provide a dependable method of controlling electrical circuits through an electromagnetic switching mechanism. When the 60 V DC coil is energised, the internal armature changes the state of the relay's three changeover contacts. Each common contact transfers between its normally closed and normally open positions, allowing connected electrical circuits to be controlled through a single coil signal. When the coil supply is removed, the contacts return to their normal positions.
The Finder 62 Series is designed for industrial applications requiring high switching capacity, durable construction and reliable electrical isolation. The 62.23.9.060.4000 combines 16 A silver tin oxide changeover contacts with reinforced coil-to-contact insulation and a compact PCB mounting arrangement. This makes it suitable for OEM equipment manufacturers, automation engineers and electronic control system designers requiring reliable multi-circuit switching within industrial equipment.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Terminal Type | PCB / pins | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Mounting Type | PCB | |
| Manufacturer | Finder | |
| Series | 62 Series Power Relays | |
| Model | 62.23.9.060.4000 | |
| Product type | Electromechanical power relay | |
| Relay configuration | 3 CO / 3PDT | |
| Number of poles | 3 | |
| Contact arrangement | Three independent changeover contacts | |
| Nominal coil voltage | 60 V DC | |
| Coil supply type | Direct current (DC) | |
| Coil operating voltage range | 48–66 V DC | |
| Nominal coil power consumption | 1.3 W | |
| Nominal coil resistance | 2,760 Ω | |
| Nominal coil current | Approximately 21.7 mA | |
| Relay operating mode | Monostable / non-latching | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated resistive load (AC1) | 4,000 VA | |
| Rated AC15 load at 230 V AC | 750 VA | |
| Single-phase motor rating at 230 V AC | 0.8 kW | |
| Three-phase motor rating at 400 V AC | 1.5 kW | |
| DC1 breaking capacity at 30 V DC | 16 A | |
| DC1 breaking capacity at 110 V DC | 0.6 A | |
| DC1 breaking capacity at 220 V DC | 0.4 A | |
| Minimum switching load | 1,000 mW | |
| Contact material | Silver tin oxide (AgSnO2) | |
| Mechanical durability | 30 million operations for DC coil versions | |
| Electrical durability at rated AC1 load | 100,000 operations | |
| Typical operating time | 11 ms | |
| Typical release time | 4 ms | |
| Rated impulse withstand voltage between coil and contacts | 6 kV | |
| Coil-to-contact insulation | Reinforced insulation | |
| Coil-to-contact clearance | 6 mm | |
| Coil-to-contact creepage distance | 8 mm | |
| Dielectric strength between open contacts | 1,500 V AC | |
| Operating temperature | −40 to +70 °C | |
| Environmental protection category | RT I | |
| Mounting type | Printed circuit board mounting | |
| Terminal type | PCB through-hole solder terminals | |
| Operating principle | Electromagnetic switching | |
| Typical applications | Industrial automation, machinery control, electrical interlocking and electronic switching assemblies |
The Finder 62.23.9.060.4000 is a three-pole electromechanical power relay used for switching electrical circuits in industrial automation, machinery control and electronic equipment. Its three changeover contacts allow three independent circuits to be controlled simultaneously using a single coil.
The relay operates with a 60 V DC nominal coil voltage. Its specified coil operating range is 48–66 V DC, making it suitable for compatible direct-current control systems.
The Finder 62.23.9.060.4000 features a 16 A rated contact current, a 250 V AC rated contact voltage and a 4,000 VA rated resistive switching capacity (AC1). The permissible switching load depends on the voltage, load characteristics and operating conditions.
3PDT means three-pole double-throw. The relay contains three independent changeover contacts, each providing common, normally open and normally closed connections. This allows three separate circuits to be switched simultaneously when the relay coil is energised.
The relay is designed for printed circuit board mounting using through-hole solder terminals. It is installed directly onto a compatible electronic control board or industrial switching assembly, with the PCB layout designed to accommodate the relay's terminal arrangement, electrical clearances and switching ratings.
Finder 62 Series power relays are designed to provide dependable high-current electrical switching for industrial automation, electronic equipment and machinery control applications. The Finder 62.23.9.060.4000 combines a 60 V DC operating coil, three 16 A changeover contacts, silver tin oxide contact technology and reinforced coil-to-contact insulation, making it a practical solution for electrical engineers, industrial equipment manufacturers and automation professionals.