62.22.9.024.0600 Finder Power relay 2pole 16A DC 24V

62.22.9.024.0600 Finder Power relay 2pole 16A DC 24V

62.22.9.024.0600 Finder Power relay 2pole 16A DC 24V.

SKU: 62.22.9.024.0600Alt SKU: 622290240600MPN: 62.22.9.024.0600
This product has been discontinued A direct replacement is available below.
62.22.9.024.4600 Finder Power relay 2pole 16A DC 24V Replacement product 62.22.9.024.4600 Finder Power relay 2pole 16A DC 24V SKU: 62.22.9.024.4600 View

Why Choose the Finder 62.22.9.024.0600 Power Relay?

The Finder 62.22.9.024.0600 is an industrial electromechanical power relay from the Finder 62 Series, designed for electrical load switching in automation systems, machinery and control panels. Its compact construction and two-pole contact arrangement make it suitable for applications requiring reliable switching from a low-voltage DC control signal.

Featuring two normally open contacts (2 NO) and a 24 V DC operating coil, the Finder 62.22.9.024.0600 provides a practical solution for controlling separate electrical circuits simultaneously. The relay is part of Finder's power relay range, developed for switching applications where dependable contact operation and integration into electrical equipment are important.

The relay is suitable for use in industrial automation, building controls and OEM equipment, with a design intended for integration into compatible electrical assemblies. Its normally open contact arrangement makes it particularly useful where circuits must remain open until the relay coil is energised.

Key Advantages

  • Two normally open contacts (2 NO) enable simultaneous switching of two electrical circuits.
  • 24 V DC operating coil is suitable for compatible industrial DC control supplies.
  • Electromechanical switching provides electrical isolation between the coil and contact circuits.
  • Normally open contact arrangement supports straightforward control of electrical loads.
  • Suitable for integration into machinery, industrial automation and electrical control equipment.
  • Two-pole configuration offers flexibility where separate circuits must respond to one control command.
  • Part of the established Finder 62 Series power relay family.
  • Useful for OEM equipment manufacture and replacement of matching relay configurations.

Key Features

  • Finder 62 Series electromechanical power relay.
  • 62.22 configuration with two normally open contacts.
  • 2 NO contact arrangement for dual-circuit switching.
  • 24 V DC nominal coil voltage.
  • DC electromagnetic coil operation.
  • Monostable relay operating principle.
  • Normally open contacts close when the coil is energised.
  • Two separate switching paths operated by a common coil.
  • Suitable for electrical load switching within the applicable manufacturer ratings.
  • Designed for integration into industrial and commercial electrical equipment.

Two-Pole Power Switching for Industrial Control Systems

The Finder 62.22.9.024.0600 provides a means of switching two electrical circuits through a single 24 V DC control signal. When the coil is energised, the relay's electromagnetic mechanism closes both normally open contacts, allowing the connected circuits to operate. When the coil is de-energised, the contacts return to their normal open positions.

This arrangement is useful in automation equipment where two loads or auxiliary circuits must be activated together. Applications may include electrical control sequencing, equipment enable functions, lighting control and switching of suitably rated loads. The relay can also be integrated into PLC-controlled systems where the controller output is capable of supplying the required coil current.

For reliable operation, the selected relay must be matched to the load voltage, current, inrush characteristics and switching duty. The exact contact ratings, terminal arrangement and installation requirements for 62.22.9.024.0600 should be checked against the applicable Finder manufacturer documentation before final equipment selection.

Typical Applications

  • Industrial electrical control panels.
  • 24 V DC automation and machinery control systems.
  • Electrical load switching and equipment enable circuits.
  • PLC-controlled switching applications.
  • Lighting and building automation controls.
  • Heating, ventilation and air conditioning (HVAC) equipment.
  • Pump and fan auxiliary control circuits.
  • Industrial signalling and control sequencing.
  • OEM machinery and electrical equipment manufacturing.
  • Maintenance and replacement of matching Finder 62 Series relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Power Relay
Manufacturer Finder
Series 62 Series Power Relays
Manufacturer part number 62.22.9.024.0600
Product type Electromechanical power relay
Contact configuration 2 NO (two normally open contacts)
Number of poles 2
Nominal coil voltage 24 V DC
Coil supply type DC
Operating principle Electromagnetic, monostable
Contact operating state Normally open when the coil is de-energised
Product family Finder 62 Series

Frequently Asked Questions

What is the Finder 62.22.9.024.0600 used for?

The Finder 62.22.9.024.0600 is an electromechanical power relay used to switch electrical circuits in automation systems, machinery and electrical control equipment. Its two normally open contacts allow two circuits to be activated by a common control signal.

What coil voltage does the Finder 62.22.9.024.0600 require?

The relay has a nominal operating coil voltage of 24 V DC. It is intended for compatible direct-current control supplies and should not be connected to an AC supply without confirming the correct relay specification.

How many contacts does the Finder 62.22.9.024.0600 have?

The relay features two normally open contacts (2 NO). Both contacts are open when the relay coil is de-energised and close when the coil is energised, allowing two separate circuits to be switched simultaneously.

Can the Finder 62.22.9.024.0600 be used with a PLC?

Yes. Its 24 V DC coil makes it suitable for use with compatible PLC and automation controller outputs, provided the output can supply the required coil current. Appropriate protection or suppression should be considered for the inductive coil load.

What should be checked before installing the Finder 62.22.9.024.0600?

Before installation, confirm the 24 V DC coil supply, two normally open contact configuration, applicable load ratings and terminal arrangement against the Finder documentation for the exact part number. The installation must also provide suitable electrical protection and comply with the equipment manufacturer's requirements.

Trusted by Industrial Automation and Control Engineers Worldwide

Finder 62 Series power relays provide electromechanical switching solutions for industrial machinery, electrical control and building automation. The Finder 62.22.9.024.0600 combines a 24 V DC operating coil with two normally open contacts, offering a practical solution for coordinated switching of electrical circuits in compatible control systems.