60.12.8.120.2000 Finder General purpose relay 2pole 10A 120V.
The Finder 60.12.8.120.2000 is a versatile Finder Series 60 plug-in electromechanical relay designed for industrial automation, electrical control panels and machinery control applications. Featuring a 120 V AC coil and two changeover contacts (DPDT, 2 CO), it provides a practical solution for switching two independent electrical circuits from a single control signal.
As part of Finder's established Series 60 general-purpose relay family, the 60.12.8.120.2000 combines dependable electromagnetic switching with a convenient plug-in construction. Its 10 A contact rating makes it suitable for a variety of control and load-switching duties, subject to the electrical characteristics of the connected equipment.
The relay is designed for installation into a suitable socket, allowing straightforward replacement during servicing without disturbing the permanent wiring. Its 120 V AC, 50/60 Hz coil is particularly useful in equipment employing this control voltage, including imported machinery, industrial control systems and OEM electrical assemblies.
The Finder 60.12.8.120.2000 operates using an electromagnetic coil that mechanically changes the position of two separate sets of contacts. When the 120 V AC coil is energised, both changeover contacts transfer from their normally closed positions to their normally open positions. When coil power is removed, the relay returns to its normal, de-energised state.
This DPDT contact arrangement makes the relay suitable for applications requiring two switching functions from a single control signal. For example, one contact may be used to operate an auxiliary circuit while the second provides status feedback or controls another compatible load. The contact circuits are electrically separate, allowing flexible control system design within the relay's specified electrical ratings.
The plug-in construction is particularly valuable in industrial maintenance environments. When installed in a correctly matched socket, the relay can be removed and replaced without rewiring the socket terminals. For reliable operation, engineers should verify the coil supply, socket compatibility, load category, contact protection and switching duty against the applicable Finder technical documentation.
Tick the specs you need, then view products that match.
| Device Type | Plug-in Relay | |
|---|---|---|
| Terminal Type | PCB / pins | |
| Mounting Type | Plug-in socket | |
| Switching Current (A) | 10 A | |
| Manufacturer | Finder | |
| Series | Series 60 General-Purpose Relays | |
| Type | 60.12 | |
| Model | 60.12.8.120.2000 | |
| Product type | Electromechanical plug-in relay | |
| Contact configuration | 2 CO (DPDT, 2 Form C) | |
| Number of poles | 2 | |
| Rated contact current | 10 A | |
| Rated contact voltage | 250 V AC | |
| Rated AC1 switching load | 2,500 VA | |
| Rated coil voltage | 120 V AC | |
| Coil supply type | AC | |
| Coil frequency | 50/60 Hz | |
| Relay operation | Monostable, non-latching | |
| Contact operation | Electromagnetically actuated changeover contacts | |
| Mounting type | Plug-in socket mounting | |
| Terminal type | Plug-in pins | |
| Socket selection | Suitable Finder socket matched to the Series 60 Type 60.12 pin arrangement | |
| Typical applications | Industrial automation, control panels, machinery and auxiliary switching circuits |
The Finder 60.12.8.120.2000 is a general-purpose industrial plug-in relay used to switch electrical circuits in automation systems, machinery and control panels. Its two changeover contacts allow two independent circuits to be controlled using a single relay coil.
The relay is designed for a nominal 120 V AC coil supply at 50/60 Hz. It should be connected to a suitably rated AC control supply rather than a DC supply.
The relay has 10 A rated contacts at 250 V AC, with a rated resistive AC1 switching load of 2,500 VA. Actual permissible switching loads depend on the load type, inrush current and operating conditions.
DPDT means double-pole double-throw, also described as 2 CO or two changeover contacts. Each pole has a common, normally open and normally closed connection, allowing two separate circuits to change state when the relay coil is energised.
The relay is designed for plug-in socket mounting. A suitable socket must be selected for the Finder Series 60 Type 60.12 terminal arrangement and the intended installation. Socket mounting enables convenient replacement without disconnecting the permanent control panel wiring.
The Finder 60.12.8.120.2000 combines a 120 V AC coil, two 10 A changeover contacts and convenient plug-in mounting in a practical industrial relay. Designed for flexible control and straightforward maintenance, it is a suitable choice for electrical panel builders, automation engineers and OEM equipment manufacturers working with compatible 120 V AC control systems.