Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 60.12.8.048.5040 is a 10 A two-pole changeover general purpose relay with a 48 V AC coil, gold-plated silver-nickel contacts and plug-in mounting for industrial automation, machinery control and auxiliary electrical switching.
The Finder 60.12.8.048.5040 is a versatile 2-pole changeover electromechanical relay designed for dependable electrical switching in industrial automation, machinery control and electrical control panels. As part of the established Finder 60 Series, this general purpose relay combines a compact plug-in construction with flexible contact arrangements for control and auxiliary switching applications.
Featuring a 48 V AC operating coil and two changeover contacts (2CO / DPDT), the Finder 60.12.8.048.5040 allows two independent electrical circuits to be controlled using a single operating signal. The Finder 60.12 relay family provides a 10 A rated contact current, making it suitable for appropriately rated control equipment, signalling circuits and industrial electrical loads.
The relay features a monostable electromagnetic operating mechanism and a practical plug-in connection system. The .5040 variant identifies a specific contact configuration within the 60 Series and should be matched by its complete manufacturer part number when selecting replacement components. Its socket-mounted construction supports convenient installation, inspection and maintenance in industrial electrical cabinets.
Electromechanical relays such as the Finder 60.12.8.048.5040 provide a practical interface between electrical control signals and switched load circuits. When the 48 V AC coil is energised, the relay's electromagnetic mechanism changes the position of its contacts, enabling connected equipment to be controlled according to the requirements of the electrical system.
The two-pole changeover configuration allows two independent circuits to respond to the same control signal. Each changeover contact provides common, normally open and normally closed switching paths, making the relay suitable for auxiliary control, electrical interlocking, equipment sequencing and signalling applications. Its monostable construction returns the contacts to their normal positions when the operating coil is de-energised.
The Finder 60 Series is designed for practical integration into industrial electrical installations. The plug-in format enables convenient replacement when used with a compatible socket, helping simplify maintenance and reduce rewiring requirements. For the 60.12.8.048.5040, the complete manufacturer part number should be used when selecting replacements to ensure that the coil supply, contact arrangement and variant-specific construction are correctly matched.
Tick the specs you need, then view products that match.
| Device Type | Plug-in Relay | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Switching Current (A) | 10 A | |
| Manufacturer | Finder | |
| Series | 60 Series General Purpose Relays | |
| Model | 60.12.8.048.5040 | |
| Product type | Electromechanical general purpose relay | |
| Relay configuration | 60.12 | |
| Contact arrangement | 2CO / DPDT | |
| Number of poles | 2 | |
| Rated contact current | 10 A | |
| Nominal coil voltage | 48 V AC | |
| Coil supply type | AC | |
| Coil operating frequency | 50/60 Hz | |
| Relay operating principle | Monostable electromagnetic | |
| Contact operation | Two independent changeover circuits | |
| Electrical connection | Plug-in terminals | |
| Mounting type | Compatible relay socket | |
| Relay family | Finder 60.12 | |
| Manufacturer variant | .5040 | |
| Application category | Industrial control and auxiliary electrical switching |
The Finder 60.12.8.048.5040 is a general purpose electromechanical relay used for switching electrical circuits in industrial automation, machinery control and electrical panels. Its two changeover contacts allow two independent circuits to be controlled using one relay coil.
The relay is designed for a nominal 48 V AC coil supply at 50/60 Hz. It should be operated using a suitable AC control supply rather than a DC supply.
The relay features two changeover contacts (2CO / DPDT). Each contact provides common, normally open and normally closed connections, allowing two independent electrical circuits to be switched.
The Finder 60.12 relay family has a 10 A rated contact current. Actual switching capability depends on the connected load, operating voltage, utilisation category and applicable variant specifications.
The .5040 suffix identifies a manufacturer-specific configuration within the Finder 60 Series. The complete part number should be matched when ordering a replacement, particularly where contact material or other variant-specific characteristics are important.
No. The Finder 60.12 family uses a monostable electromagnetic operating principle. Its contacts change position when the coil is energised and return to their normal positions when the coil is de-energised.
The relay is designed for plug-in socket mounting in electrical control equipment. The selected socket must be compatible with the relay's terminal arrangement, contact configuration and manufacturer variant.
Finder 60 Series general purpose relays provide dependable electrical switching for industrial automation, machinery control and electrical installations. Their practical plug-in construction, versatile changeover contact arrangements and established electromagnetic relay technology make them a reliable choice for control panel builders, electrical engineers and industrial maintenance professionals.