Finder 58.34.9.024.0089SMA four-pole relay interface module for 24 V DC control systems, with 4PDT silver-nickel contacts, 6 A hazardous-area contact rating, DIN-rail mounting, screw terminals, modular timer configuration and mechanical indicator. Listed in Finder’s ATEX and HazLoc range.
£70.86
The Finder 58.34.9.024.0089SMA is a 24 V DC four-pole relay interface module from the Finder 58 Series, designed for industrial automation, PLC interfacing and electrical control applications where hazardous-area compliance is required. Its complete ordering code is listed in Finder's published catalogue under the ATEX and HazLoc product range.
Featuring four changeover contacts (4 CO / 4PDT), the module allows one control signal to operate four separate switching circuits. It combines an electromechanical relay with a screw-terminal interface socket and is designed for mounting on a standard 35 mm DIN rail.
Unlike standard Finder 58.34 interface modules, which have a general-purpose 7 A contact rating, the hazardous-area version has a 6 A nominal contact rating, with additional current limits depending on the certification, ambient temperature and installation arrangement. The 0089 configuration incorporates a modular timing function and a mechanical indicator, making it a specialised interface solution for suitably designed industrial control systems.
Important hazardous-area rating note: Finder's 58 Series documentation specifies 6 A for a single hazardous-area 58.34 module at the relevant ATEX/IECEx conditions, reducing to 4 A for certain grouped installations at +70 °C. HazLoc ratings are 5 A under the specified +40 °C conditions. These values must not be replaced by the standard non-ATEX 7 A rating.
Exact configuration note: Finder's published price list identifies 58.34.9.024.0089SMA as an ATEX/HazLoc variant. The 58 Series ordering system identifies the 8 option position with the Finder 86.30 timing module and the final 9 with the hazardous-area version incorporating a mechanical indicator. The complete assembly's certification, permitted timing functions and any additional limitations must be checked against the current Finder approval documents.
The Finder 58.34.9.024.0089SMA belongs to the specialist 58 Series interface range intended for electrical equipment operating under defined hazardous-location requirements.
Finder's hazardous-area interface family includes versions designed to meet ATEX and IECEx Ex ec nC requirements and HazLoc Class I, Division 2 classifications. Such applications may include industrial process equipment, chemical handling systems and electrical control panels installed in appropriately classified environments.
Hazardous-area approval is not determined by the relay alone. The complete assembly, including its timer module, wiring, enclosure, temperature limits and installation conditions, must comply with the applicable certification. The module must not be assumed suitable for Zone 0, Zone 1 or other classifications outside its documented approval.
The 0089 special configuration includes a timing-module option associated with the Finder 86.30 modular timer. This enables timed control functions in compatible relay interface assemblies, supporting applications where relay operation needs to be coordinated with other equipment.
Typical timing requirements include controlled equipment start-up, auxiliary switching delays and process sequencing. The exact selectable timing modes and adjustment range depend on the fitted timer module and should be verified against the appropriate Finder 86.30 documentation.
When a modular timer is installed, the permissible operating temperature may be narrower than that of the relay alone. Finder's 58 Series documentation identifies a −20 to +50 °C ambient range when used with an 86 modular timer, before any additional hazardous-area approval restrictions are considered.
The Finder 58.34.9.024.0089SMA provides four changeover contact sets, allowing several electrical circuits to be controlled through one interface module.
Each pole includes a common connection, a normally open contact and a normally closed contact. This arrangement is useful where a PLC or control system needs to operate multiple auxiliary outputs, alarm signals or control circuits.
The AgNi contacts support general-purpose switching, while the hazardous-area construction requires the applicable 6 A or lower derated contact limits to be respected. Inductive and DC loads must also be assessed using their appropriate switching ratings.
The module is designed for installation on a 35 mm DIN rail in accordance with EN 60715. Its 27 mm width supports compact integration into electrical control panels.
The screw-terminal interface provides connections for the relay contacts and control supply. Finder specifies an 8 mm wire stripping length and 0.5 Nm tightening torque for the relevant interface terminal family.
Installation in a hazardous area must follow the complete manufacturer's instructions, including restrictions on energised connection or disconnection, enclosure requirements, approved wiring practices, ambient temperature and the maximum permitted load current.
Tick the specs you need, then view products that match.
| Device Type | Interface Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Switching Current (A) | 6 A | |
| Load Voltage | 250 V AC | |
| Mounting Type | DIN rail | |
| Manufacturer | Finder | |
| Manufacturer part number | 58.34.9.024.0089SMA | |
| Series | 58 Series | |
| Module type | 58.34 | |
| Product category | Hazardous-area electromechanical relay interface module | |
| Nominal control voltage | 24 V DC | |
| Coil version | DC | |
| Contact configuration | 4 CO / 4PDT | |
| Number of poles | 4 | |
| Number of changeover contacts | 4 | |
| Contact material | Silver nickel (AgNi) | |
| Rated contact current | 6 A, hazardous-area version | |
| Maximum peak contact current | 15 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 250 V AC | |
| Rated resistive switching capacity (AC1) | 1,500 VA | |
| Rated AC15 switching capacity at 230 V AC | 350 VA | |
| Single-phase motor rating at 230 V AC | 0.24 kW | |
| DC1 breaking capacity at 24 V DC | 6 A | |
| DC1 breaking capacity at 110 V DC | 0.25 A | |
| DC1 breaking capacity at 220 V DC | 0.12 A | |
| Minimum switching load | 300 mW (5 V / 5 mA) | |
| Relay mechanical life, DC coil | 50 million cycles | |
| Electrical life at rated AC1 load | 150,000 cycles | |
| Relay operate time | Approximately 11 ms, excluding any timer delay | |
| Relay release time | Approximately 15 ms, excluding any timer delay | |
| Coil-to-contact impulse withstand voltage | 3.6 kV | |
| Dielectric strength between open contacts | 1,000 V AC | |
| Dielectric strength between adjacent contacts | 1,550 V AC | |
| Environmental protection | IP20 | |
| Mounting type | 35 mm DIN rail | |
| Terminal type | Screw / box-clamp terminals | |
| Terminal tightening torque | 0.5 Nm | |
| Wire stripping length | 8 mm | |
| Module width | 27 mm | |
| Mechanical indicator | Fitted as part of the special 0089 configuration | |
| Timing module | Finder 86.30 timer configuration | |
| ATEX / IECEx protection marking, product family | II 3G Ex ec nC IIC Gc | |
| HazLoc classification, product family | Class I, Division 2, Groups A, B, C, D, T5 | |
| ATEX / IECEx ambient temperature range | −40 to +70 °C for the relay interface family, subject to timer-module restrictions | |
| HazLoc ambient temperature range | −25 to +40 °C under the published family conditions | |
| Ambient temperature range when fitted with Finder 86 modular timer | −20 to +50 °C, subject to certification restrictions |
The Finder 58.34.9.024.0089SMA is a four-pole relay interface module intended for industrial automation, PLC interfacing and suitably designed hazardous-area control applications. Its special configuration includes a modular timing function and mechanical indication.
The module is designated for a 24 V DC nominal control supply. The electrical characteristics of the relay and fitted timing module must be checked together before connection, including any polarity and supply restrictions.
The module provides four changeover contacts (4 CO / 4PDT). Each pole includes common, normally open and normally closed connections, enabling four separate switching circuits to be operated through one interface assembly.
No. Although the standard Finder 58.34 interface module is rated at 7 A, the hazardous-area version has a 6 A nominal contact rating. Lower limits apply under certain grouped ATEX/IECEx installations and HazLoc operating conditions. The applicable certified rating must be used.
The 0089 configuration identifies a hazardous-area version with a Finder 86.30 modular timer option and a mechanical indicator. The SMA ordering suffix is associated with the screw-terminal interface assembly. The complete assembly's certification and timer functions should be confirmed using Finder's current product documentation.
The Finder 58.34.9.024.0089SMA combines a 24 V DC relay interface, four changeover contacts, DIN-rail installation, screw-terminal wiring and specialist hazardous-area configuration. Its modular timing capability makes it a practical choice for engineered control systems where switching, sequencing and applicable ATEX/IECEx or HazLoc requirements must be considered together.