56.42.8.230.2300 Finder Miniature power relay 2pole 12A 230V.
The Finder 56.42.8.230.2300 is a robust industrial electromagnetic power relay from the Finder 56 Series, designed for reliable electrical switching in machinery, automation equipment and industrial control panels. Featuring a 230 V AC nominal coil and two changeover contacts (2 CO / DPDT), this relay provides a practical solution for controlling two independent electrical circuits using a single control signal.
Unlike miniature signal relays, the Finder 56 Series is designed for applications requiring higher contact switching capacity. The 56.42 configuration provides a 12 A nominal contact current rating, making it suitable for appropriately rated electrical loads, auxiliary equipment and industrial control circuits.
The Finder 56.42.8.230.2300 combines a versatile double-pole changeover arrangement with plug-in construction for installation in compatible Finder relay sockets. Its electromagnetic switching mechanism, compact industrial design and service-friendly installation make it a practical choice for electrical panel builders, automation engineers and machinery manufacturers.
The Finder 56.42.8.230.2300 uses an electromagnetic coil to operate two changeover contact sets. When the appropriate 230 V AC control voltage is applied, the relay changes the position of both contacts. When the coil is de-energised, the contacts return to their normal positions, providing conventional monostable operation.
Each changeover contact provides a common terminal that switches between normally closed and normally open connections. This DPDT arrangement allows a single control signal to perform two separate switching functions, such as operating an auxiliary load while simultaneously changing a control or status circuit.
The 12 A nominal contact rating makes the Finder 56.42 suitable for applications requiring greater switching capacity than many miniature control relays. However, the permissible load depends on the operating voltage, load characteristics, inrush current, power factor and switching frequency. Inductive loads, motors and electronic power supplies may require additional contact protection or suitably rated switching equipment.
Its plug-in construction provides practical installation and maintenance advantages. When fitted into a compatible Finder socket, the relay can be removed and replaced without disconnecting the permanent socket wiring. This can simplify equipment servicing, troubleshooting and component replacement in industrial control panels.
For applications involving frequent switching or inductive loads, engineers should select appropriate coil suppression and contact protection measures in accordance with the electrical characteristics of the installation. The relay should always be used within the manufacturer's specified operating limits.
Tick the specs you need, then view products that match.
| Device Type | Power Relay | |
|---|---|---|
| Mounting Type | Plug-in socket | |
| Manufacturer | Finder | |
| Series | 56 Series | |
| Part number | 56.42.8.230.2300 | |
| Product type | Industrial electromagnetic power relay | |
| Relay configuration | 56.42 | |
| Nominal coil voltage | 230 V AC | |
| Coil supply type | AC | |
| Contact arrangement | 2 CO / DPDT / 2 Form C | |
| Number of poles | 2 | |
| Number of changeover contacts | 2 | |
| Nominal contact current | 12 A | |
| Nominal contact voltage | 250 V AC | |
| Contact function | Changeover | |
| Relay operation | Monostable, non-latching | |
| Switching technology | Electromagnetic | |
| Electrical connection | Plug-in terminals | |
| Mounting | Compatible relay socket | |
| Socket family | Finder 96 Series, subject to exact compatibility | |
| Application | Industrial automation, machinery control and electrical load switching |
The Finder 56.42.8.230.2300 is an industrial electromagnetic power relay used to switch two separate electrical circuits from a single 230 V AC control signal. Typical applications include industrial automation, machinery control, auxiliary load switching and electrical control panels.
The relay has a 230 V AC nominal coil voltage. It should be operated using a compatible AC control supply within the manufacturer's specified operating voltage and frequency limits.
The relay features two changeover contacts (2 CO / DPDT). Each contact set provides common, normally open and normally closed connections, allowing two independent electrical circuits to be switched simultaneously.
The Finder 56.42 relay configuration has a 12 A nominal contact current rating and a nominal contact voltage of 250 V AC. Actual permissible switching capacity depends on the operating voltage, load type, inrush current and switching conditions.
The Finder 56.42 relay family is designed for plug-in installation using compatible Finder 96 Series relay sockets. The correct socket should be selected according to the relay's terminal arrangement, mounting requirements and electrical ratings.