Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 48.P6.8.024.1060SPA industrial interface relay module with a 24 V AC coil, 16 A single changeover contact, push-in terminals, integrated supply indication and EMC coil suppression, and 15.8 mm DIN rail mounting for industrial automation and PLC control applications.
£13.60
The Finder 48.P6.8.024.1060SPA is a compact 16 A industrial electromechanical interface relay module from the Finder 48 Series, designed for dependable switching in PLC systems, electrical control panels and industrial automation equipment. Featuring a 24 V AC operating coil, a single changeover contact and convenient push-in terminals, this relay interface provides an efficient connection between electronic control systems and electrical loads.
The Finder 48.P6 design combines a replaceable electromechanical relay with a slimline DIN rail socket assembly. Its single-pole double-throw (SPDT / 1 CO) contact configuration provides normally open and normally closed switching paths, while the standard silver-nickel (AgNi) contact material supports reliable switching of appropriately rated industrial loads.
With a 16 A rated contact current, 250 V AC rated contact voltage and 15.8 mm module width, the Finder 48.P6.8.024.1060SPA is suitable for space-conscious industrial installations. Its push-in wiring connections, integrated supply indication and EMC coil suppression module simplify panel assembly, operation and maintenance.
The Finder 48.P6.8.024.1060SPA provides an effective interface between a 24 V AC control circuit and a separate electrical switching circuit. When the coil is energised, the relay transfers its common contact from the normally closed position to the normally open position. When the coil supply is removed, the contact returns to its original state, enabling dependable control of connected electrical equipment.
A major benefit of the 48.P6 interface design is its push-in terminal connection system, which supports efficient wiring during control panel manufacture and maintenance. Combined with the slim 15.8 mm housing, this makes the module particularly suitable for densely populated electrical cabinets and industrial automation assemblies.
The Finder 48.P6 relay interface also includes supply status indication and EMC coil suppression as standard. These features assist maintenance personnel with visual monitoring and help limit electrical disturbances associated with coil switching. For applications above 10 A, the manufacturer's specified parallel contact-terminal connections must be followed to achieve the applicable higher-current rating.
Tick the specs you need, then view products that match.
| Device Type | Interface Relay | |
|---|---|---|
| Terminal Type | Push-in | |
| Load Voltage | 400 V AC | |
| Mounting Type | DIN rail | |
| Switching Current (A) | 16 A | |
| Manufacturer | Finder | |
| Manufacturer part number | 48.P6.8.024.1060SPA | |
| Series | 48 Series | |
| Interface type | 48.P6 | |
| Product type | Electromechanical interface relay module | |
| Nominal coil voltage | 24 V AC | |
| Coil frequency | 50/60 Hz | |
| Coil type | AC electromagnetic | |
| Rated AC coil consumption | 1.2 VA at 50 Hz | |
| AC operating voltage range | 0.8–1.1 × nominal voltage | |
| AC holding voltage | 0.8 × nominal voltage | |
| AC must drop-out voltage | 0.2 × nominal voltage | |
| Relay operating principle | Monostable electromagnetic switching | |
| Contact configuration | Single-pole double-throw (SPDT / 1 CO) | |
| Number of poles | 1 | |
| Number of changeover contacts | 1 | |
| Standard contact material | Silver nickel (AgNi) | |
| Rated contact current | 16 A | |
| Maximum peak contact current | 30 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Rated resistive switching load (AC1) | 4,000 VA | |
| Rated switching load (AC15 at 230 V AC) | 1,000 VA | |
| Single-phase motor rating at 230 V AC | 0.55 kW | |
| DC1 breaking capacity at 24 V DC | 16 A | |
| DC1 breaking capacity at 110 V DC | 0.6 A | |
| DC1 breaking capacity at 220 V DC | 0.25 A | |
| Minimum switching load | 500 mW (10 V / 5 mA) | |
| Mechanical life | 10 million cycles | |
| Electrical life at rated AC1 load | 100,000 cycles | |
| Nominal operate time | 7 ms for AC coil versions | |
| Nominal release time | 14 ms for AC coil versions | |
| Coil-to-contact impulse withstand voltage | 6 kV (1.2/50 µs) | |
| Coil-to-contact insulation distance | 8 mm | |
| Dielectric strength between open contacts | 1,000 V AC | |
| Operating temperature | −40 to +70 °C | |
| Protection category | IP20 | |
| Mounting type | DIN rail | |
| DIN rail standard | EN 60715, 35 mm | |
| Terminal type | Push-in | |
| Module width | 15.8 mm | |
| Supply indication | Integrated status indicator | |
| Coil protection | Integrated EMC suppression module | |
| Relay construction | Replaceable plug-in relay and socket assembly | |
| Important wiring requirement | For currents above 10 A, Finder specifies parallel connection of contact terminals 21 with 11, 24 with 14 and 22 with 12. | |
| Application category | Industrial automation, PLC interfacing and electrical switching |
The Finder 48.P6.8.024.1060SPA is an industrial interface relay module designed to switch electrical loads using a separate low-voltage control circuit. Typical applications include PLC interfaces, industrial control panels, machinery control, building automation and auxiliary electrical switching.
The Finder 48.P6.8.024.1060SPA uses a 24 V AC coil. The .8. coil designation identifies the AC version, and the nominal coil consumption for the associated Finder 48.P6 AC relay family is 1.2 VA at 50 Hz.
The Finder 48.P6 interface relay has a 16 A rated contact current and a 250 V AC rated contact voltage, with a resistive AC1 switching capacity of 4,000 VA. For currents above 10 A, Finder specifies that the relevant contact terminals must be connected in parallel according to the manufacturer's wiring diagram.
Both relay interface types provide one 16 A changeover contact and a slimline DIN rail mounting arrangement. The principal difference is the terminal connection system: the 48.P6 uses push-in terminals, while the 48.61 uses box-clamp screw terminals. The preferred version depends on the control panel's wiring and maintenance requirements.
Yes. The Finder 48.P6.8.024.1060SPA is designed for 35 mm DIN rail mounting in accordance with EN 60715. Its 15.8 mm width, push-in terminal connections and replaceable relay construction make it suitable for industrial control cabinets where space efficiency and convenient maintenance are important.
Finder 48 Series interface relays provide reliable electrical switching for automation engineers, control panel builders and industrial maintenance teams. The Finder 48.P6.8.024.1060SPA combines a 24 V AC operating coil, 16 A changeover contact, push-in terminal technology and slimline DIN rail mounting for efficient integration into industrial control systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.