Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 48.52.8.120.5060SMA industrial relay interface module featuring a 120 V AC operating coil, two 8 A DPDT changeover contacts, screw-terminal connections and slim 35 mm DIN rail mounting for electrical switching in PLC systems and industrial automation control panels.
£20.36
The Finder 48.52.8.120.5060SMA is a compact 8 A industrial relay interface module from the Finder 48 Series, designed for electrical switching and signal interfacing in industrial automation systems, PLC control panels and machinery. Combining an electromechanical relay with a DIN rail mounting socket, this interface module provides a convenient solution for connecting control circuits to compatible electrical loads.
Featuring a 120 V AC nominal operating coil and two changeover contacts (2 CO / DPDT), the Finder 48.52.8.120.5060SMA allows two independent electrical circuits to be switched simultaneously using a single control signal. The relay interface platform supports an 8 A rated contact current and 250 V AC rated contact voltage, making it suitable for appropriately rated industrial switching applications.
The module features a slim 15.8 mm housing width, screw-terminal connections and mounting compatibility with standard 35 mm DIN rails. Its replaceable relay construction, integrated supply indication and coil suppression arrangement make the Finder 48.52 platform particularly useful for panel builders, maintenance engineers and automation professionals seeking compact and serviceable relay interfaces. The .5060SMA suffix identifies a specific ordering configuration whose additional contact and packaging details should be confirmed against the manufacturer's documentation.
The Finder 48.52.8.120.5060SMA is designed to simplify the connection between an electrical control signal and the equipment being switched. When the 120 V AC operating coil is energised, the relay mechanism transfers both changeover contacts from their normally closed connections to their normally open connections. Removing the coil supply allows the contacts to return to their original positions.
The dual changeover contact arrangement provides flexibility for auxiliary switching, status signalling, interlocking and control logic applications. Each contact pole offers common, normally open and normally closed terminals, enabling two separate circuits to be controlled from one relay interface module. The 8 A contact rating makes the module suitable for a wide range of compatible electrical loads, provided the relevant load-specific switching limits are respected.
Its 15.8 mm DIN rail format is particularly advantageous where multiple interface relays must be installed within a limited control panel space. Screw terminals allow straightforward field wiring, while the removable relay and supply indication simplify maintenance and fault identification. For inductive loads, motors and circuits with significant inrush current, the manufacturer's applicable switching ratings and any required external protection should be considered during system design.
Tick the specs you need, then view products that match.
| Device Type | Interface Relay | |
|---|---|---|
| Terminal Type | Screw | |
| Switching Current (A) | 8 A | |
| Mounting Type | DIN rail | |
| Manufacturer | Finder | |
| Series | Finder 48 Series | |
| Model | 48.52.8.120.5060SMA | |
| Product type | Industrial electromechanical relay interface module | |
| Relay interface type | 48.52 | |
| Relay operation | Monostable, non-latching | |
| Contact configuration | 2 CO (DPDT / 2 Form C) | |
| Number of poles | 2 | |
| Nominal coil voltage | 120 V AC | |
| Coil supply type | AC | |
| Nominal coil frequency | 50/60 Hz | |
| Coil operating voltage range | 96 to 132 V AC | |
| Nominal AC coil consumption | 1.2 VA | |
| Rated contact current | 8 A | |
| Maximum peak contact current | 15 A | |
| Rated contact voltage | 250 V AC | |
| Rated AC1 switching capacity | 2000 VA | |
| Rated AC15 switching capacity | 400 VA at 230 V AC | |
| Single-phase motor rating | 0.3 kW at 230 V AC | |
| DC1 breaking capacity | 8 A at 30 V DC | |
| Minimum switching load | 300 mW (5 V / 5 mA) | |
| Typical operate time | 7 ms for AC coil versions | |
| Typical release time | 4 ms for AC coil versions | |
| Mechanical endurance | 10 million cycles under specified conditions | |
| Electrical endurance | 100,000 cycles at rated AC1 load | |
| Coil-to-contact impulse withstand voltage | 6 kV | |
| Coil-to-contact insulation distance | 8 mm | |
| Dielectric strength between open contacts | 1000 V AC | |
| Operating temperature range | −40 to +70 °C | |
| Protection category | IP20 | |
| Mounting type | 35 mm DIN rail | |
| Terminal type | Screw terminals | |
| Module width | 15.8 mm | |
| Supply indication | Integrated indication module | |
| Coil suppression | Integrated EMC suppression module | |
| Replaceable relay | Yes | |
| Ordering suffix | 5060SMA; exact suffix-specific configuration requires confirmation |
The Finder 48.52.8.120.5060SMA is an industrial relay interface module used for electrical switching in PLC systems, machinery and control panels. Its two changeover contacts allow two independent electrical circuits to be controlled using a 120 V AC operating coil.
The module has a 120 V AC nominal operating coil, designed for 50/60 Hz AC control supplies. The published operating range for the 120 V AC version of the 48.52 platform is 96 to 132 V AC.
The Finder 48.52 platform features two changeover contacts (2 CO / DPDT) with an 8 A rated contact current and a 250 V AC rated contact voltage. Its rated AC1 switching capacity is 2000 VA. Actual permissible loads depend on their electrical characteristics and switching duty.
Yes. The Finder 48.52 relay interface platform is designed for 35 mm DIN rail mounting in accordance with EN 60715. It features a slim 15.8 mm width and screw-terminal connections for integration into industrial electrical control panels.
The standard Finder 48.52 interface platform includes a supply status indication and EMC coil suppression module. These features assist with troubleshooting and managing coil switching disturbances. The exact indication colour and any additional features associated with the .5060SMA ordering suffix should be confirmed against the manufacturer's specification.
Finder 48 Series relay interface modules provide compact, serviceable switching solutions for PLC systems, industrial machinery and electrical control panels. The Finder 48.52.8.120.5060SMA combines a 120 V AC control input, dual 8 A changeover contacts and slim DIN rail mounting to support reliable electrical interfacing in compatible automation applications.
We use cookies