40.61.9.005.1300 Finder Miniature PCB relay 1pole 16A DC 5V

40.61.9.005.1300 Finder Miniature PCB relay 1pole 16A DC 5V

Finder 40.61.9.005.1300 Series 40 miniature electromechanical power relay with a 5 V DC standard coil, 16 A rated contact current and one SPDT changeover contact for compatible PCB switching, industrial automation and electronic control applications.

SKU: 40.61.9.005.1300Alt SKU: 406190051300MPN: 40.61.9.005.1300
Price on application Contact us for pricing and availability.
Call 01708 343600

Finder 40.61.9.005.1300 – 16 A, 5 V DC Miniature Power Relay

The Finder 40.61.9.005.1300 is a miniature electromechanical power relay from the Finder Series 40 range. Featuring a 5 V DC standard coil and a 16 A single changeover contact (1 CO / SPDT), it is designed for electrical switching in compatible electronic control systems, printed circuit board assemblies and industrial automation equipment.

The Finder Type 40.61 combines a compact housing with substantial switching capability. Its 250 V AC rated contact voltage and 4000 VA AC-1 switching capacity make it suitable for a wide range of appropriately rated electrical loads, including control equipment, appliances and industrial switching circuits.

The 5 V DC standard coil has a nominal consumption of approximately 0.65 W, enabling operation from a suitable low-voltage DC supply through an appropriately rated relay-driver circuit.

The .1300 suffix identifies a specific construction variant within the Finder Type 40.61 family. The exact variant-specific features, including contact material, terminal arrangement and enclosure classification, should be verified against Finder's current ordering documentation before the relay is specified or substituted.

Key Advantages

  • 16 A rated contact current for compatible electrical power-switching applications.
  • 5 V DC standard coil for low-voltage electronic control systems.
  • Approximately 0.65 W nominal coil consumption for efficient electromechanical operation.
  • One changeover contact (1 CO / SPDT) provides normally open and normally closed switching functions.
  • 250 V AC rated contact voltage for compatible mains-voltage circuits.
  • 400 V AC maximum switching voltage under specified operating conditions.
  • 4000 VA AC-1 switching capacity for suitable resistive loads.
  • Compact miniature construction for space-efficient electrical assemblies.
  • 5 mm contact pin pitch within the Type 40.61 PCB layout.
  • 6 kV impulse withstand voltage between coil and contacts.
  • 8 mm coil-to-contact creepage and clearance for substantial electrical separation.
  • Monostable operation returns the contacts to their normal state when coil power is removed.
  • Finder Series 40 platform for PCB and compatible socket-based installations.

Key Features

  • Finder Series 40 miniature electromechanical power relay.
  • Type 40.61 single-pole changeover design.
  • Manufacturer part number: 40.61.9.005.1300.
  • Rated contact current: 16 A.
  • Nominal coil voltage: 5 V DC.
  • Coil classification: Standard DC.
  • Contact configuration: 1 CO / SPDT.
  • Rated contact voltage: 250 V AC.
  • Maximum switching voltage: 400 V AC.
  • Rated AC-1 switching capacity: 4000 VA.
  • Nominal coil resistance: 38 Ω.
  • Nominal coil current: 130 mA.
  • Nominal coil consumption: approximately 0.65 W.
  • Typical operate time: 7 ms.
  • Typical release time: 3 ms.
  • Monostable, non-latching operation.
  • Compact Type 40.61 housing.
  • Suitable for compatible PCB and plug-in socket arrangements.

Important specification note: The core Type 40.61 ratings and the 9.005 standard DC-coil data are established Series 40 specifications. The exact 40.61.9.005.1300 construction variant has not been independently verified against a current manufacturer product record. Do not assume that the .1300 suffix guarantees RT III wash-tight protection, a particular contact material, a high-temperature rating or a specific pin configuration without checking Finder's documentation.

5 V DC Standard Coil for Electronic Control Applications

The Finder 40.61.9.005.1300 uses a 5 V DC standard coil, allowing a compatible low-voltage control circuit to operate a separate electrical load.

The 9.005 coil code identifies the standard DC-coil version. Its nominal resistance is 38 Ω, with a rated coil current of approximately 130 mA at 5 V DC.

This corresponds to a nominal coil power consumption of approximately 0.65 W.

The specified coil operating range extends from approximately 3.65 to 7.5 V DC, subject to the manufacturer's conditions. A nominal 5 V DC supply should be selected and regulated appropriately for the intended installation.

In electronic control systems, the relay can be operated using a suitably rated transistor, MOSFET or dedicated relay-driver circuit.

Because the coil draws approximately 130 mA, it should not be connected directly to a microcontroller output unless that output is specifically rated to provide the required current.

Appropriate coil transient suppression should be included where necessary to protect the driver electronics when the relay is switched off.

Standard DC Coil Versus Sensitive DC Coil

Finder Series 40 relays are available with different DC-coil configurations, including standard and sensitive versions.

The 40.61.9.005.1300 uses a standard DC coil, while a comparable Type 40.61 relay with coil code 7.005 uses a sensitive DC coil.

Although both operate at a nominal 5 V DC, their electrical characteristics differ:

  • Standard 5 V DC coil (9.005): Approximately 38 Ω, 130 mA and 0.65 W.
  • Sensitive 5 V DC coil (7.005): Approximately 50 Ω, 100 mA and 0.5 W.

These differences can affect the relay-driver circuit, power supply capacity, thermal behaviour and coil operating characteristics.

When replacing an existing relay, the coil code must be checked rather than selecting a replacement solely by nominal voltage.

16 A Changeover Contact for Flexible Electrical Switching

The Finder Type 40.61 incorporates one changeover contact (1 CO / SPDT).

The contact arrangement provides three switching connections:

  • Common (COM): The shared contact terminal.
  • Normally closed (NC): Connected to common when the relay is de-energised.
  • Normally open (NO): Connected to common when the relay is energised.

When the 5 V DC coil is energised, the relay transfers the common contact from the normally closed path to the normally open path.

When the coil supply is removed, the contacts return to their normal position.

This arrangement enables a single relay to provide on/off switching, changeover control, signalling and electrical interlocking functions.

The 16 A rated contact current and 4000 VA AC-1 switching capacity apply under the manufacturer's specified conditions.

Load type must be considered carefully. Motors, transformers, solenoids, capacitive circuits and LED drivers can produce substantial inrush currents or switching transients, which may reduce contact life or require a different relay configuration.

High Electrical Isolation Between Coil and Contacts

The Finder Type 40.61 provides substantial electrical separation between the low-voltage control coil and the switched contact circuit.

The standard design incorporates 8 mm creepage and clearance between coil and contacts, together with a specified 6 kV impulse withstand voltage.

These characteristics support applications where electronic control circuitry must switch a separate higher-voltage electrical load.

The complete equipment must still meet applicable electrical safety requirements, including PCB clearances, conductor ratings, protective devices and enclosure design.

Understanding the .1300 Construction Variant

The .1300 suffix forms part of Finder's complete ordering code and identifies a specific construction configuration.

Finder Series 40 relays can be supplied with different contact materials, environmental protection classifications and terminal arrangements.

Some variants are intended for standard PCB assembly, while others may provide additional protection for specified cleaning processes or different application requirements.

For the 40.61.9.005.1300, the precise meaning of the .1300 suffix should be checked against the manufacturer's current ordering information.

It is particularly important not to assume that the .1300 version is interchangeable with .1000, .1001 or other construction variants simply because the contact rating and coil voltage are the same.

Compact PCB and Socket Mounting

The Finder Type 40.61 belongs to a compact relay family designed for printed circuit boards and compatible plug-in socket installations.

The standard relay body measures approximately 29 × 12.4 × 25 mm, with a 5 mm contact pin pitch.

Selected Finder Series 95 sockets provide additional installation flexibility, including DIN rail mounting where the correct socket is used.

Before specifying a PCB footprint or socket, the exact terminal arrangement and pin dimensions associated with the .1300 construction suffix should be confirmed.

Any socket, PCB copper track, connector or terminal used with the relay must also be rated for the intended current and operating conditions.

Typical Applications

  • Printed circuit board power switching.
  • Industrial automation systems.
  • Electronic equipment control boards.
  • 5 V DC control circuits.
  • Machine control electronics.
  • Building automation equipment.
  • Heating and ventilation control systems.
  • Electrical load changeover circuits.
  • Industrial monitoring and signalling equipment.
  • Electronic appliance control assemblies.
  • OEM electrical and electronic equipment.
  • Compatible motor and actuator control circuits.
  • Industrial maintenance and equipment repair.
  • Replacement of matching Finder Series 40 relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Plug-in Relay
Load Voltage 400 V AC
Switching Current (A) 16 A
Manufacturer Finder
Series 40 Series
Relay type 40.61
Manufacturer part number 40.61.9.005.1300
Product category Miniature electromechanical power relay
Relay technology Electromechanical
Operating principle Monostable / non-latching
Number of poles 1
Contact configuration 1 CO / SPDT
Contact form Form C
Rated contact current 16 A
Maximum peak contact current 30 A for the standard Type 40.61 contact specification; alternative contact materials may have different peak ratings
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated AC-1 switching capacity 4000 VA
Rated AC-15 switching capacity at 230 V AC 750 VA for the standard Type 40.61 contact specification
Single-phase motor rating at 230 V AC 0.55 kW for the standard Type 40.61 contact specification
DC-1 breaking capacity at 30 V DC 16 A
DC-1 breaking capacity at 110 V DC 0.3 A
DC-1 breaking capacity at 220 V DC 0.12 A
Minimum switching load 500 mW for the standard contact specification
Nominal coil voltage 5 V DC
Coil supply type DC
Coil classification Standard DC
Coil code 9.005
Nominal coil resistance 38 Ω
Nominal coil current 130 mA
Nominal coil consumption Approximately 0.65 W
Minimum specified coil operating voltage 3.65 V DC
Maximum specified coil operating voltage 7.5 V DC
Typical operate time 7 ms
Typical release time 3 ms
Mechanical life Up to 20,000,000 operations for the standard DC-coil Type 40.61 design
Electrical life at rated AC-1 load 100,000 operations under specified conditions
Coil-to-contact impulse withstand voltage 6 kV (1.2/50 µs)
Coil-to-contact creepage and clearance 8 mm
Dielectric strength between open contacts 1000 V AC
Standard Series 40 operating temperature range −40 to +85 °C, subject to variant and load derating
Contact pin pitch 5 mm for the Type 40.61 layout
Approximate Type 40.61 body dimensions 29 × 12.4 × 25 mm
Mounting family PCB / compatible plug-in socket
Compatible accessory family Selected Finder Series 95 sockets
Contact material Exact .1300 variant to be confirmed against Finder's ordering documentation
Enclosure classification Exact .1300 variant to be confirmed against Finder's ordering documentation
Applicable general relay standard EN 61810-1

Frequently Asked Questions

What is the Finder 40.61.9.005.1300 used for?

The Finder 40.61.9.005.1300 is a miniature electromechanical power relay used to switch compatible electrical loads from a 5 V DC control circuit. Typical applications include PCB assemblies, industrial automation, electronic equipment and electrical control systems.

What coil voltage does the Finder 40.61.9.005.1300 require?

The relay uses a nominal 5 V DC standard coil. Its specified operating voltage range is approximately 3.65 to 7.5 V DC, subject to the manufacturer's conditions.

What is the contact current rating of the Finder 40.61.9.005.1300?

The Finder Type 40.61 has a 16 A rated contact current. The permissible switching current depends on the load type, operating voltage, ambient temperature and installation conditions.

What contact configuration does the Finder 40.61.9.005.1300 have?

The relay features one changeover contact (1 CO / SPDT), providing common, normally open and normally closed switching connections.

Can the Finder 40.61.9.005.1300 switch 230 V AC?

The Finder Type 40.61 has a 250 V AC rated contact voltage and can switch compatible 230 V AC loads within the manufacturer's specified current and utilisation ratings.

What is the coil resistance of the Finder 40.61.9.005.1300?

The standard 5 V DC coil has a nominal resistance of 38 Ω, drawing approximately 130 mA at its rated voltage.

What is the coil power consumption of the Finder 40.61.9.005.1300?

The relay's standard DC coil consumes approximately 0.65 W at its nominal 5 V DC supply voltage.

Is the Finder 40.61.9.005.1300 a latching relay?

No. It is a monostable electromechanical relay. Its contacts return to their normal position when the coil supply is removed.

What does the 1300 suffix mean?

The .1300 suffix identifies a specific Finder Series 40 construction variant. Its exact contact material, enclosure classification and terminal configuration should be confirmed using Finder's current ordering documentation.

Is the Finder 40.61.9.005.1300 wash-tight?

The exact enclosure classification of the .1300 variant has not been independently confirmed. Do not assume RT III wash-tight protection without checking the manufacturer's part-number specification.

What is the difference between the Finder 40.61.9.005.1300 and 40.61.7.005.1300?

Both part numbers identify Finder Type 40.61 relays with nominal 5 V DC coils. The key difference is the coil version: the 9.005 designation indicates a standard DC coil, while 7.005 indicates a sensitive DC coil. Their coil resistance and current requirements differ.

Can the Finder 40.61.9.005.1300 be controlled by a microcontroller?

Yes, provided an appropriately rated relay-driver circuit is used. The standard 5 V DC coil draws approximately 130 mA, so the microcontroller output should not be assumed capable of driving it directly.

A Compact 5 V DC Relay for Industrial and Electronic Switching

The Finder 40.61.9.005.1300 combines a 5 V DC standard coil, 16 A changeover contact and compact Finder Series 40 construction. It is a practical choice for compatible PCB-based power switching, industrial automation and electronic control systems requiring dependable electromechanical operation. Confirm the exact .1300 construction details and applicable load ratings before installation or substitution.