Finder 40.61.8.024.1000 Series 40 miniature electromechanical power relay with a 24 V AC 50/60 Hz coil, 16 A rated contact current, one SPDT changeover contact, AgNi contact material and RT II flux-proof construction for compatible industrial automation and electronic control applications.
The Finder 40.61.8.024.1000 is a compact 16 A, 24 V AC miniature electromechanical power relay from the Finder Series 40 range. Designed for printed circuit boards, electrical control systems and industrial automation equipment, it combines a high-current changeover contact with a dependable AC-operated coil.
Featuring one changeover contact (1 CO / SPDT), the relay allows a common connection to switch between normally closed and normally open circuits. Its 16 A rated contact current, 250 V AC rated contact voltage and 4000 VA AC-1 switching capacity make it suitable for a wide range of compatible electrical loads.
The 24 V AC coil operates at 50/60 Hz and has a nominal consumption of approximately 1.2 VA. This makes the relay particularly useful in control systems that use 24 V AC transformers, including building services equipment, machinery and industrial electrical installations.
The 40.61.8.024.1000 also features silver nickel (AgNi) contacts, a compact PCB and plug-in construction, and an RT II flux-proof enclosure classification. Its miniature dimensions allow integration into equipment where installation space is limited.
Technical note: The 16 A contact rating and 4000 VA AC-1 capacity apply under specified electrical conditions. Inductive, capacitive and high-inrush loads require separate assessment. The maximum switching voltage is not a continuous operating recommendation, and compatible socket ratings may be lower than the relay's standalone rating.
The Finder 40.61.8.024.1000 uses a 24 V AC coil designed for operation at 50/60 Hz.
Low-voltage AC control supplies are widely used in electrical control panels, building services installations and automation equipment. A 24 V AC relay can therefore be useful where a control transformer provides the operating supply.
The relay's nominal coil resistance is 320 Ω, with a nominal apparent power consumption of approximately 1.2 VA.
When selecting the control transformer, designers should account for the relay coil's apparent power requirements, transformer regulation, voltage drop in the wiring and any other loads connected to the same supply.
Important: This is an AC-coil relay. It should not be substituted for a 24 V DC version simply because the nominal voltage is the same. AC and DC coils have different electrical characteristics and must be matched to the control supply.
The Finder Type 40.61 incorporates one changeover contact, also known as a single-pole double-throw (SPDT) contact.
The contact arrangement provides three electrical connections:
When the 24 V AC coil is energised, the relay transfers the common connection from the normally closed contact to the normally open contact. When the coil supply is removed, the contacts return to their original position.
This allows the relay to be used for load switching, electrical changeover, interlocking and signalling functions.
The 16 A rated contact current is suitable for compatible loads within the manufacturer's specified ratings. However, motors, transformers, solenoids, LED drivers and capacitive equipment may produce significant inrush currents or switching transients.
These applications should be assessed against the relevant load-specific switching characteristics rather than the resistive-load current rating alone.
The Finder 40.61.8.024.1000 uses silver nickel (AgNi) contacts.
Silver nickel is a widely used contact material in electromechanical relays, offering a practical combination of electrical conductivity, mechanical durability and resistance to contact wear under suitable operating conditions.
AgNi contacts are used in a range of industrial control and general-purpose switching applications.
The suitability of the contact material depends on the electrical load. Low-level signals, highly inductive loads and circuits with substantial inrush current may require different contact specifications or additional protective components.
For replacement applications, the contact material should be considered alongside the coil voltage, contact arrangement and mounting dimensions.
The 40.61.8.024.1000 has an RT II flux-proof enclosure classification.
Flux-proof construction is intended to help protect the relay's internal components against flux penetration during appropriate PCB soldering processes.
This is particularly useful in electronic manufacturing, where relays may be fitted to printed circuit boards alongside other through-hole components.
It is important to distinguish RT II flux-proof from RT III wash-tight construction.
An RT II relay should not automatically be subjected to PCB washing processes intended for wash-tight components. Manufacturers should follow Finder's current soldering and cleaning recommendations to avoid damaging the relay.
The Finder 40.61.8.024.1000 is designed for through-hole PCB mounting and compatible plug-in socket arrangements.
Its approximate dimensions of 29 × 12.4 × 25 mm make it suitable for electronic assemblies where installation space is limited.
The relay uses a 5 mm contact pin pitch. The correct PCB footprint should be confirmed using the manufacturer's dimensional drawing before board manufacture.
Compatible Finder Series 95 sockets may also be used to provide plug-in installation and easier relay replacement.
Where a socket is used, its current rating, terminal capacity, insulation characteristics and mechanical compatibility must be checked. The permissible current through a socket may be lower than the relay's 16 A contact rating.
Tick the specs you need, then view products that match.
| Device Type | Plug-in Relay | |
|---|---|---|
| Mounting Type | PCB, Plug-in socket | |
| Switching Current (A) | 16 A | |
| Load Voltage | 400 V AC | |
| Manufacturer | Finder | |
| Series | 40 Series | |
| Type | 40.61 | |
| Manufacturer part number | 40.61.8.024.1000 | |
| Product category | Miniature PCB / plug-in power relay | |
| Relay technology | Electromechanical | |
| Operating principle | Monostable / non-latching | |
| Number of poles | 1 | |
| Contact configuration | 1 CO / SPDT | |
| Contact form | Form C | |
| Rated contact current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Maximum switching voltage | 400 V AC | |
| Maximum AC-1 switching capacity | 4000 VA | |
| Contact material | Silver nickel (AgNi) | |
| Nominal coil voltage | 24 V AC | |
| Coil supply type | AC | |
| Coil frequency | 50/60 Hz | |
| Nominal coil resistance | 320 Ω | |
| Nominal coil consumption | Approximately 1.2 VA | |
| Typical operate time | Approximately 7 ms | |
| Typical release time | Approximately 3 ms | |
| Coil-to-contact insulation | High-isolation Series 40 design; verify the applicable dielectric and impulse test ratings in Finder's current datasheet | |
| Enclosure classification | RT II flux-proof | |
| IP protection classification | IP20, as listed for this relay configuration | |
| Contact pin pitch | 5 mm | |
| Mounting | Through-hole PCB / compatible plug-in socket | |
| Approximate dimensions | 29 × 12.4 × 25 mm | |
| Approximate weight | 17.1 g | |
| Socket compatibility | Selected Finder Series 95 sockets | |
| EAN | 8012823447278 | |
| Country of origin | Italy |
The Finder 40.61.8.024.1000 is a miniature electromechanical power relay used to switch compatible electrical loads from a 24 V AC control circuit. Typical applications include industrial automation, PCB assemblies, building control systems and electrical equipment.
The relay requires a nominal 24 V AC supply at 50/60 Hz. It is designed for AC control circuits rather than DC coil operation.
No. The Finder 40.61.8.024.1000 is specified for a 24 V AC coil. A suitable DC-coil relay should be selected for a 24 V DC control supply.
The relay has a 16 A rated contact current. The permissible switching load depends on the operating voltage, load type, ambient temperature and installation conditions.
The relay has one changeover contact (1 CO / SPDT), providing common, normally open and normally closed switching connections.
Yes. The relay has a 250 V AC rated contact voltage and can switch compatible 230 V AC loads within its specified current and utilisation ratings.
The relay uses silver nickel (AgNi) contacts, a contact material commonly used in general-purpose electromechanical switching applications.
The 24 V AC coil has a nominal resistance of 320 Ω and an approximate apparent power consumption of 1.2 VA.
No. It is a monostable electromechanical relay. Its contacts return to their normal position when the coil supply is removed.
No. This specific relay is listed with an RT II flux-proof enclosure classification, which is different from RT III wash-tight construction. It should not automatically be subjected to PCB washing processes.
Yes. It is designed for through-hole PCB mounting and uses a 5 mm contact pin pitch. The manufacturer's dimensional drawing should be used to confirm the correct PCB footprint.
Both models belong to the Finder Series 40 Type 40.61 family and feature a 16 A changeover contact. The main difference is the nominal coil voltage: the 40.61.8.024.1000 uses a 24 V AC coil, while the 40.61.8.012.1000 uses a 12 V AC coil. They are not directly interchangeable without matching the control supply.
The Finder 40.61.8.024.1000 combines a 24 V AC coil, 16 A silver nickel changeover contact and compact PCB/plug-in construction. With its RT II flux-proof enclosure and versatile SPDT switching arrangement, it provides a practical solution for industrial automation, building control systems and electronic power-switching applications requiring dependable electromechanical operation.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.