40.61.7.005.1001 Finder Miniature PCB relay 1pole 16A DC 5V

40.61.7.005.1001 Finder Miniature PCB relay 1pole 16A DC 5V

Finder 40.61.7.005.1001 Series 40 miniature electromechanical power relay with a 5 V DC sensitive coil, 16 A rated contact current and one SPDT changeover contact for compatible electronic control, automation and electrical power-switching applications.

SKU: 40.61.7.005.1001Alt SKU: 406170051001MPN: 40.61.7.005.1001
Price on application Contact us for pricing and availability.
Call 01708 343600

Why Choose the Finder 40.61.7.005.1001 PCB Power Relay?

The Finder 40.61.7.005.1001 is a compact 16 A, 5 V DC electromechanical power relay from the Finder Series 40 range. Designed for PCB-based electrical control and power switching applications, the relay combines a high-current changeover contact with a sensitive DC coil in a space-efficient miniature housing.

Based on the Finder Type 40.61 design, this relay features one changeover contact (1 CO / SPDT), allowing a common connection to switch between normally closed and normally open terminals. Its 16 A rated contact current makes it suitable for a range of compatible electrical loads, including control circuits, automation equipment, appliances and electronic switching systems.

The 5 V DC sensitive coil allows the relay to be operated by a suitably rated low-voltage electronic control circuit. The Series 40 design also provides substantial electrical separation between the control coil and switching contacts, making it useful in equipment that requires low-voltage control of separate electrical loads.

The 40.61.7.005.1001 is a specific variant within the Series 40 family. The exact contact-material and enclosure options associated with the .1001 suffix should be checked against Finder's current product documentation before selecting it as a replacement for another 40.61 relay.

Key Advantages

  • 16 A rated contact current for compatible power-switching applications.
  • 5 V DC sensitive coil for low-voltage electronic control circuits.
  • Single changeover contact (1 CO / SPDT) provides flexible switching functionality.
  • 250 V AC rated contact voltage for compatible mains-voltage circuits.
  • 400 V AC maximum switching voltage under the manufacturer's specified conditions.
  • 4000 VA AC-1 switching capacity for suitable resistive loads.
  • Miniature relay housing for compact electronic equipment.
  • 5 mm contact pin pitch for compatible PCB layouts and relay sockets.
  • 6 kV impulse withstand insulation between coil and contacts.
  • 8 mm creepage and clearance between coil and contact circuits.
  • Monostable operation provides predictable switching and automatic return when coil power is removed.
  • Finder Series 40 construction suitable for a wide range of industrial and electronic applications.

Key Features

  • Finder Series 40 miniature power relay.
  • Type 40.61 single-pole changeover design.
  • 16 A rated contact current.
  • 5 V DC nominal coil voltage.
  • Sensitive DC coil version.
  • 1 CO / SPDT contact arrangement.
  • 250 V AC rated contact voltage.
  • 400 V AC maximum switching voltage.
  • 4000 VA rated AC-1 switching capacity.
  • 750 VA rated AC-15 switching capacity at 230 V AC.
  • 0.55 kW single-phase motor rating at 230 V AC.
  • 6 kV coil-to-contact impulse withstand voltage.
  • 8 mm coil-to-contact creepage and clearance.
  • 5 mm contact pin pitch.
  • Monostable, non-latching electromechanical operation.
  • Compatible with appropriate Finder Series 95 socket arrangements, subject to the exact pin configuration.

Technical note: The principal electrical ratings above are based on Finder's published Type 40.61 Series 40 specifications. The precise contact material, enclosure classification, pin length and approval status of the .1001 configuration should be verified against the manufacturer part-number documentation. When mounted in a socket, the permissible contact current may be lower than the relay's standalone 16 A rating.

5 V DC Sensitive Coil for Electronic Control Systems

The Finder 40.61.7.005.1001 uses a 5 V DC sensitive coil, allowing it to be incorporated into compatible low-voltage electronic control systems.

The sensitive DC coil version of the Series 40 is designed to reduce coil power requirements compared with higher-consumption relay configurations. With a nominal coil consumption of approximately 0.5 W, the relay can be driven using an appropriately rated electronic switching stage.

For microcontroller, PLC or embedded control applications, the relay should normally be operated through a suitable transistor, MOSFET or relay-driver circuit rather than directly from a low-current logic output.

Appropriate coil transient suppression should also be considered to protect the associated control electronics when the relay is switched off. The selected suppression arrangement must be compatible with the required relay release characteristics.

16 A Changeover Contact for Flexible Power Switching

The Type 40.61 relay features one changeover contact, commonly described as SPDT (single-pole double-throw).

In its normal, de-energised state, the common contact is connected to the normally closed terminal. When the coil receives its rated control voltage, the relay operates and transfers the common connection to the normally open terminal.

This arrangement allows the relay to perform several useful functions, including:

  • Switching a load on when a control signal is applied.
  • Disconnecting a circuit when the relay is energised.
  • Changing between two alternative circuit paths.
  • Providing an electrical interlock or control status signal.
  • Operating compatible electrical loads from low-voltage electronics.

The 16 A contact rating applies under the manufacturer's specified conditions. Different load types, including motors, solenoids, transformers and LED drivers, can impose additional switching demands. The appropriate utilisation rating and inrush current must therefore be considered during circuit design.

High Electrical Isolation Between Coil and Contacts

A key feature of the Finder Series 40 relay design is its electrical separation between the low-voltage coil circuit and the switched contacts.

The Type 40.61 provides 8 mm creepage and clearance and a specified 6 kV impulse withstand voltage between coil and contacts.

These characteristics make the relay useful in electronic equipment where a low-voltage control circuit must operate a separate higher-voltage electrical load.

Electrical isolation within the relay does not replace the need for correct PCB layout, protective earthing where applicable, suitable insulation distances, overcurrent protection and compliance with the safety standards governing the complete equipment.

PCB and Socket Mounting Options

The Finder Series 40 range supports direct PCB installation and compatible plug-in socket arrangements. The Type 40.61 uses a 5 mm contact pin pitch, allowing integration into suitable printed circuit board designs.

Compatible Finder Series 95 sockets can provide additional mounting flexibility, including installation on a DIN rail when the correct socket is selected.

When choosing a mounting arrangement, engineers should verify the exact relay pin length, socket compatibility and current-carrying capability. The maximum current permitted through a socket may be lower than the standalone relay contact rating.

The .1001 suffix should be checked against Finder's ordering information to ensure the correct mounting and construction options are selected.

Typical Applications

  • Industrial electronic control equipment.
  • Printed circuit board power switching.
  • Low-voltage control of compatible mains-powered loads.
  • PLC output interface circuits.
  • Electronic appliance control systems.
  • Building automation equipment.
  • Machine control electronics.
  • Heating and ventilation control equipment.
  • Power supply and load switching circuits.
  • Electronic monitoring and alarm systems.
  • OEM electronic product manufacturing.
  • Industrial automation control assemblies.
  • Compatible motor and actuator switching.
  • Maintenance and replacement of matching Finder Series 40 relays.

Technical Specifications

Tick the specs you need, then view products that match.

Device Type Plug-in Relay
Load Voltage 400 V AC
Switching Current (A) 16 A
Manufacturer Finder
Series 40 Series
Type 40.61
Manufacturer part number 40.61.7.005.1001
Product category Miniature power relay
Relay technology Electromechanical
Operating principle Monostable / non-latching
Number of poles 1
Contact configuration 1 CO / SPDT
Contact form Form C
Rated contact current 16 A
Maximum peak contact current 30 A for the standard Type 40.61 contact specification
Rated contact voltage 250 V AC
Maximum switching voltage 400 V AC
Rated AC-1 switching capacity 4000 VA
Rated AC-15 switching capacity at 230 V AC 750 VA
Single-phase motor rating at 230 V AC 0.55 kW
DC-1 breaking capacity at 30 V DC 16 A
DC-1 breaking capacity at 110 V DC 0.3 A
DC-1 breaking capacity at 220 V DC 0.12 A
Nominal coil voltage 5 V DC
Coil supply type DC
Coil version Sensitive DC
Nominal sensitive-coil consumption 0.5 W
Approximate nominal coil current 100 mA
Approximate nominal coil resistance 50 Ω
Coil-to-contact impulse withstand voltage 6 kV (1.2/50 µs)
Coil-to-contact creepage and clearance 8 mm
Dielectric strength between open contacts 1000 V AC
Contact pin pitch 5 mm
Mounting arrangement PCB / compatible plug-in socket, subject to exact variant
Contact material Confirm .1001-specific configuration against manufacturer documentation
Environmental protection Confirm .1001-specific enclosure classification
Operating temperature Check the current variant-specific datasheet
Socket family Finder Series 95, where compatible
Applicable relay standard EN 61810-1

Frequently Asked Questions

What is the Finder 40.61.7.005.1001 used for?

The Finder 40.61.7.005.1001 is a miniature electromechanical power relay used for switching compatible electrical loads through a low-voltage control circuit. Typical applications include PCB assemblies, automation equipment, electronic appliances and industrial control systems.

What coil voltage does the Finder 40.61.7.005.1001 require?

The relay uses a 5 V DC sensitive coil. The control circuit must provide the appropriate DC voltage and sufficient coil current for reliable operation.

What is the contact current rating of the Finder 40.61.7.005.1001?

The Finder Type 40.61 has a 16 A rated contact current. The permissible load depends on the switching voltage, load characteristics and mounting arrangement. Compatible relay sockets may have a lower current rating.

What contact configuration does the Finder 40.61.7.005.1001 have?

The relay has one changeover contact (1 CO / SPDT), providing a common terminal and normally open and normally closed switching paths.

Can the Finder 40.61.7.005.1001 switch 230 V AC?

The Type 40.61 has a 250 V AC rated contact voltage and can switch compatible 230 V AC loads within its specified electrical ratings. The load current, utilisation category and installation safety requirements must be checked before use.

Is the Finder 40.61.7.005.1001 a latching relay?

No. It is a monostable electromechanical relay. Its contacts return to their normal position when the coil is de-energised.

Can the Finder 40.61.7.005.1001 be controlled by a microcontroller?

Yes, when an appropriate relay-driver circuit is used. The 5 V DC coil requires more current than most microcontroller output pins can safely supply directly, so a suitably rated transistor or relay-driver stage is normally required.

Can the Finder 40.61.7.005.1001 be mounted on a PCB?

The Finder Type 40.61 belongs to a PCB and plug-in relay range with a 5 mm contact pin pitch. The exact pin length and mounting arrangement for the .1001 variant should be checked against the manufacturer's dimensional drawing.

Can this relay be installed on a DIN rail?

The Finder Series 40 can be used with selected Finder Series 95 DIN rail sockets. The relay itself is not a standalone DIN rail module, and the correct socket must be chosen for the exact relay variant.

What is the difference between the Finder 40.61.7.005.1001 and 40.61.7.005.0000?

Both part numbers identify Finder Type 40.61 relays with 5 V DC sensitive coils. The different suffixes indicate variant-specific construction or ordering options. Their contact material, enclosure and mounting details should be compared using Finder's current ordering information before substitution.

What electrical isolation does the Finder Type 40.61 provide?

The Type 40.61 design provides 8 mm creepage and clearance between coil and contacts, together with a specified 6 kV impulse withstand voltage. The complete equipment must still meet the relevant electrical safety and insulation requirements.

Designed for Electronics Engineers and Industrial Automation Professionals

The Finder 40.61.7.005.1001 combines a sensitive 5 V DC coil, 16 A changeover contact and compact Series 40 construction. It provides a practical solution for electronic power switching, industrial control equipment and PCB-based automation systems where dependable electromechanical operation and effective separation between control and load circuits are important.