imo mcor-2-42 thermal overload relay for mc24-mc40 contactors 28-42 amps

imo mcor-2-42 thermal overload relay for mc24-mc40 contactors 28-42 amps

IMO MCOR-2-42 thermal overload relay with adjustable 28-42A current range, manual or automatic reset and 1NO plus 1NC auxiliary contacts for industrial motor protection applications.

SKU: MCOR-2-42Alt SKU: MCOR242MPN: MCOR-2-42
Price
List Price £98.94 ex VAT
Your Price (ex VAT) Save 30%
£69.26 30% OFF
You save £29.68 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £69.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£69.26

Why Choose the IMO MCOR-2-42 Thermal Overload Relay?

The IMO MCOR-2-42 is a high-performance thermal overload relay engineered to provide reliable motor protection for industrial control and automation systems. Designed specifically for use with the IMO MC contactor series, this overload relay protects motors against overload conditions, phase failure and excessive current draw, helping extend motor life and reduce downtime in demanding industrial environments.

Part of the proven IMO MCOR overload relay range, the MCOR-2-42 features an adjustable current setting range of 28 to 42A, with star-delta protection support up to 48 to 73A. It includes manual and automatic reset functionality together with integrated 1NO + 1NC auxiliary contacts for flexible control circuit integration.

Its compact direct-mount design allows seamless installation onto compatible IMO contactors from the MC24 to MC40 range, creating a safe and efficient motor starter solution for industrial machinery, pumps, fans and automation equipment.

Key Advantages

  • Reliable thermal overload motor protection for industrial applications.
  • Adjustable overload range from 28 to 42A.
  • Supports star-delta motor protection from 48 to 73A.
  • Manual or automatic reset operation.
  • 1NO + 1NC auxiliary contacts included.
  • Compact direct mounting onto IMO MC contactors.

Key Features

  • IMO MCOR thermal overload relay series.
  • 28 - 42A adjustable current range.
  • 48 - 73A YD star-delta protection range.
  • Suitable for MC24 to MC40 contactors.
  • Manual/automatic reset selector.
  • 1NO + 1NC auxiliary contacts.
  • Integrated thermal motor protection.
  • Compact industrial direct-mount design.

Reliable Motor Protection for Industrial Systems

Thermal overload relays such as the IMO MCOR-2-42 are designed to protect motors from overheating caused by overload conditions, stalled rotors or phase imbalance. By disconnecting the motor before thermal damage occurs, overload relays help improve system reliability and minimise costly downtime in industrial environments.

The MCOR range is specifically designed to integrate directly with IMO MC contactors, creating a compact and reliable motor starter assembly suitable for machinery, conveyors, HVAC systems and automation equipment.

Typical Applications

  • Industrial motor starters.
  • Pumps and ventilation systems.
  • Conveyors and material handling equipment.
  • HVAC and refrigeration systems.
  • Industrial automation machinery.
  • Three-phase motor protection systems.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type Direct mount on contactor
Device Type Thermal Overload Relay
Current Range 28–42 A
Compatible With MC24–MC40
Reset Type Manual / Automatic
Phase Three Phase
Poles 3-pole
Series MCOR Thermal Overload Relays
Product type Thermal overload relay
Adjustable current range 28 - 42A
Star-delta range 48 - 73A
Compatible contactors IMO MC24 to MC40
Auxiliary contacts 1NO + 1NC
Reset mode Manual or automatic selectable
Mounting type Direct mounting or remote mounting using terminal block
Number of poles 3 pole
Rated operational voltage up to 690V AC
Terminal type Screw clamp terminals
Protection function Thermal overload and phase failure protection
Flexible cable capacity 0.75 - 6mm² power circuit
Control circuit cable capacity 0.5 - 2.5mm²
Operating temperature -25°C to +60°C
Weight approx. 0.3kg
Standards IEC/EN 60947-4-1
Approvals CE, UL, cUL, RoHS compliant
HS Code 8536303000
Country of Manufacture Austria

Frequently Asked Questions

What is the IMO MCOR-2-42 used for?

This thermal overload relay protects industrial motors against overload conditions and phase failure in motor starter applications.

What current range does this overload relay support?

The MCOR-2-42 has an adjustable overload protection range from 28 to 42A.

Does this relay support star-delta motor starters?

Yes. The MCOR-2-42 supports star-delta applications from 48 to 73A.

Which contactors are compatible with this relay?

This overload relay is designed for use with IMO MC24 to MC40 contactors.

Does the relay support manual and automatic reset?

Yes. The MCOR-2-42 includes selectable manual and automatic reset modes.