imo c4/100r-90 thermal/mag motor circuit breaker 70-90a

imo c4/100r-90 thermal/mag motor circuit breaker 70-90a

IMO C4/100R-90 thermal magnetic motor circuit breaker with 70-90 A adjustable current range and 1170 A magnetic trip release for industrial motor protection and control panel applications.

SKU: C4/100R-90Alt SKU: C4100R90MPN: C4/100R-90
Price
List Price £299.52 ex VAT
Your Price (ex VAT) Save 30%
£209.66 30% OFF
You save £89.86 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £209.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£209.66

Why Choose the IMO C4/100R-90 Thermal Magnetic Motor Circuit Breaker?

The IMO C4/100R-90 is a robust thermal magnetic motor circuit breaker designed to provide reliable protection for industrial motors, control panels and machinery applications. As part of the IMO C4 motor protection circuit breaker range, it combines adjustable thermal overload protection with magnetic short-circuit protection in a compact, panel-friendly format.

This motor protection circuit breaker helps safeguard motors against overloads, phase failure conditions and high fault currents, reducing the risk of equipment damage and unplanned downtime. Its rotary handle design, DIN rail mounting capability and accessory compatibility make it suitable for use in modern motor control centres and industrial automation panels.

With an adjustable current range of 70-90 A and a magnetic trip rating of 1170 A, the C4/100R-90 is ideal for protecting larger three-phase motors used in production machinery, pumps, fans, compressors and material handling systems.

Key Advantages

  • Reliable thermal magnetic motor circuit breaker for industrial motor protection.
  • 70-90 A adjustable current range for larger motor loads.
  • 1170 A magnetic short-circuit release for fault protection.
  • Rotary handle operation for clear switching and isolation.
  • DIN rail mounting for straightforward control panel installation.
  • Suitable for motor control, automation and machinery applications.

Key Features

  • IMO C4 motor protection circuit breaker series.
  • Thermal magnetic trip technology.
  • Adjustable overload setting from 70-90 A.
  • Magnetic trip release rated at 1170 A.
  • Three-pole motor protection design.
  • Rotary knob operation for secure switching.
  • Compatible with selected IMO C4 accessories.
  • Designed for DIN rail and panel mounting applications.

Reliable Protection for Industrial Motors

Motor protection circuit breakers such as the IMO C4/100R-90 are used to protect electric motors from overload and short-circuit conditions. The adjustable thermal setting allows the device to be matched to the motor current, while the magnetic trip mechanism provides fast disconnection during high fault current events.

The C4 range is widely used in motor starter assemblies, control panels and machine installations where dependable switching, overload protection and compact installation are required. Its design supports efficient panel building while helping maintain safe and reliable motor operation.

Typical Applications

  • Industrial motor starter panels.
  • Pumps, fans and compressors.
  • Conveyors and material handling systems.
  • Manufacturing and production machinery.
  • Motor control centres and automation panels.
  • Machine building and electrical distribution systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current Range 63–100 A
Device Type Motor protection breaker
Application Motor protection
Actuator Type Rotary
Terminal Type Screw Terminal
Current 90 A
Poles 3-pole
Manufacturer IMO
Series C4 Motor Protection Circuit Breakers
Model C4/100R-90
Alternative SKU C4100R90
Product type Thermal magnetic motor circuit breaker
Current adjustment range 70-90 A
Magnetic trip release 1170 A
Poles 3-pole
Operation Rotary handle
Mounting type DIN rail / panel mounting
DIN rail compatibility 35 mm and 70 mm DIN rail
Application Motor protection and isolation
Manufacturer part number C4/100R-90
Barcode 5056207414619
HS Code 8536209090
Country of Manufacture South Korea

Frequently Asked Questions

What is the IMO C4/100R-90 used for?

The IMO C4/100R-90 is used to protect three-phase motors against overload and short-circuit conditions in industrial control panels and machinery.

What current range does this motor circuit breaker cover?

This model has an adjustable thermal current range of 70-90 A.

What is the magnetic trip rating?

The C4/100R-90 has a magnetic short-circuit release rating of 1170 A.

How is the C4/100R-90 installed?

It is designed for installation in electrical control panels using DIN rail or panel mounting methods.

What types of equipment is it suitable for?

It is suitable for larger industrial motors used with pumps, fans, compressors, conveyors, production machinery and motor starter panels.

Trusted by Industrial Control Engineers Worldwide

IMO C4 motor protection circuit breakers are used by panel builders, maintenance engineers and machine builders to provide dependable motor protection, safe switching and reliable control in demanding industrial environments.