imo c4/100r-75 thermal/mag motor circuit breaker 55-75a

imo c4/100r-75 thermal/mag motor circuit breaker 55-75a

IMO C4/100R-75 thermal magnetic motor protection circuit breaker with adjustable overload range of 55.0 to 75.0A and 975A magnetic trip for industrial motor protection.

SKU: C4/100R-75Alt SKU: C4100R75MPN: C4/100R-75
Price
List Price £279.41 ex VAT
Your Price (ex VAT) Save 30%
£195.59 30% OFF
You save £83.82 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £195.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£195.59

Why Choose the IMO C4/100R-75 Motor Protection Circuit Breaker?

The IMO C4/100R-75 is a heavy-duty thermal magnetic motor protection circuit breaker (MPCB) designed to provide reliable protection for three-phase electric motors against overloads, short circuits and phase failure. As part of the IMO C4 Motor Protection Circuit Breaker series, it is engineered for demanding industrial machinery, motor starter assemblies, automation systems and OEM control panels.

This motor protection circuit breaker features an adjustable thermal overload setting from 55.0 to 75.0A together with a fixed 975A magnetic short-circuit trip. Its thermal magnetic protection provides accurate overload sensing while delivering rapid fault clearance to protect motors, cables and associated equipment.

Designed for industrial panel mounting, the C4/100R-75 combines overload protection, short-circuit protection and manual motor isolation within one compact device. Its robust construction makes it suitable for larger motors operating in demanding manufacturing and process applications.

Key Advantages

  • Heavy-duty thermal magnetic motor protection circuit breaker.
  • Adjustable overload range of 55.0 to 75.0A.
  • 975A magnetic short-circuit trip.
  • Protects against overload, short circuit and phase failure.
  • Manual motor isolation and switching capability.
  • Suitable for industrial motor starter and automation panels.

Key Features

  • IMO C4 Motor Protection Circuit Breaker series.
  • 55.0 to 75.0A adjustable thermal setting.
  • 975A instantaneous magnetic trip.
  • Three-pole motor protection.
  • Thermal magnetic trip mechanism.
  • Phase failure sensitivity.
  • Short-circuit breaking capacity up to 50kA at 400V AC.
  • Compatible with auxiliary contacts and control accessories.

Reliable Motor Protection for Industrial Applications

Motor protection circuit breakers combine overload protection, short-circuit protection and manual isolation within one compact device. The IMO C4 series simplifies motor control panel design while providing dependable protection for electric motors operating in industrial automation, manufacturing and process control environments.

The C4/100R-75 is ideally suited to protecting motors with a full load current between 55.0A and 75.0A, helping reduce downtime, improve operational safety and maximise equipment reliability.

Typical Applications

  • Industrial motor starters.
  • Large pumps and compressors.
  • Material handling and conveyor systems.
  • Industrial fans and ventilation equipment.
  • Manufacturing and processing machinery.
  • OEM automation systems.

Technical Specifications

Tick the specs you need, then view products that match.

Current Range 40–63 A, 63–100 A
Application Motor protection
Actuator Type Rotary
Terminal Type Screw Terminal
Current 75 A
Poles 3-pole
Device Type Motor protection breaker
Breaking Capacity 50 kA
Manufacturer IMO Precision Controls
Series C4 Motor Protection Circuit Breakers
Model C4/100R-75
Product type Thermal magnetic motor protection circuit breaker
Thermal adjustment range 55.0 to 75.0A
Magnetic trip 975A
Suitable motor power Up to approximately 37kW at 400V AC
Number of poles 3
Rated operational voltage Up to 690V AC
Rated insulation voltage 1000V
Frequency 50 / 60Hz
Short-circuit breaking capacity Up to 50kA at 400V AC
Protection Overload, short circuit and phase failure
Mounting type Panel mounting
Protection rating IP20
Standards IEC/EN 60947-1, IEC/EN 60947-2 and IEC/EN 60947-4-1
HS Code 8536209090
Country of Manufacture South Korea

Frequently Asked Questions

What is the IMO C4/100R-75 used for?

It protects three-phase electric motors against overloads, short circuits and phase failure while providing manual motor isolation.

What overload range does this motor protection circuit breaker provide?

The adjustable thermal setting range is 55.0 to 75.0A.

What is the magnetic trip setting?

The magnetic short-circuit release is factory set at approximately 975A.

What size motor is this breaker suitable for?

It is suitable for protecting motors up to approximately 37kW at 400V AC, depending on the application.

Where is this breaker typically installed?

It is typically installed in industrial motor control centres, machinery control panels and OEM automation systems.

Trusted by Industrial Engineers Worldwide

IMO C4 motor protection circuit breakers are trusted by panel builders, OEMs and industrial engineers for dependable motor protection, safe isolation and reliable long-term performance in demanding industrial applications.