imo c4/100r-63 thermal/mag motor circuit breaker 45-63a

imo c4/100r-63 thermal/mag motor circuit breaker 45-63a

IMO C4/100R-63 thermal magnetic motor protection circuit breaker with adjustable overload range of 40.0 to 63.0A for three-phase industrial motor protection.

SKU: C4/100R-63Alt SKU: C4100R63MPN: C4/100R-63
Price
List Price £254.31 ex VAT
Your Price (ex VAT) Save 30%
£178.02 30% OFF
You save £76.29 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £178.02
Trade pricing is personalised to your account

Manufacturer Lead Time

£178.02

Why Choose the IMO C4/100R-63 Motor Protection Circuit Breaker?

The IMO C4/100R-63 is a robust thermal magnetic motor protection circuit breaker (MPCB) designed to provide reliable protection for three-phase electric motors against overloads, short circuits and phase failure. As part of the IMO C4 Motor Protection Circuit Breaker series, it is engineered for industrial machinery, motor starter assemblies, automation panels and OEM control systems requiring dependable motor protection.

This motor protection circuit breaker features an adjustable thermal overload setting from 40.0 to 63.0A with a high instantaneous magnetic short-circuit trip level. The thermal magnetic design provides accurate overload protection while ensuring rapid disconnection under fault conditions, helping protect motors, cables and connected equipment.

Designed for panel installation in industrial control systems, the C4/100R-63 combines overload protection, short-circuit protection and manual motor isolation within a compact and durable device. It is suitable for larger motors and higher-current applications where reliable switching, protection and isolation are essential.

Key Advantages

  • Heavy-duty thermal magnetic motor protection circuit breaker.
  • Adjustable overload range of 40.0 to 63.0A.
  • Designed for higher-current three-phase motor protection.
  • Protects against overload, short circuit and phase failure.
  • Manual motor isolation and switching capability.
  • Suitable for industrial motor starters and control panels.

Key Features

  • IMO C4 Motor Protection Circuit Breaker series.
  • 40.0 to 63.0A adjustable thermal setting.
  • Three-pole motor protection.
  • Thermal magnetic trip mechanism.
  • Phase failure sensitivity.
  • High short-circuit breaking capacity.
  • Manual reset and isolation functionality.
  • Compatible with industrial motor control accessories.

Reliable Motor Protection for Industrial Applications

Motor protection circuit breakers combine overload protection, short-circuit protection and manual isolation in one dedicated device. The IMO C4 series helps simplify motor control panel design while providing dependable protection for electric motors used in industrial automation, manufacturing, pumping and processing applications.

The C4/100R-63 is suited to protecting motors with a full load current between 40.0A and 63.0A, helping reduce downtime, improve operational safety and extend motor service life in demanding industrial environments.

Typical Applications

  • Industrial motor starters.
  • Machine building and OEM equipment.
  • Automation and process control panels.
  • Pumps, fans and compressors.
  • Conveyor and material handling systems.
  • Manufacturing and production equipment.

Technical Specifications

Tick the specs you need, then view products that match.

Current Range 40–63 A
Application Motor protection
Actuator Type Rotary
Terminal Type Screw Terminal
Current 63 A
Poles 3-pole
Device Type Motor protection breaker
Manufacturer IMO Precision Controls
Series C4 Motor Protection Circuit Breakers
Model C4/100R-63
Product type Thermal magnetic motor protection circuit breaker
Thermal adjustment range 40.0 to 63.0A
Number of poles 3
Rated operational voltage Up to 690V AC
Rated insulation voltage 690V AC
Frequency 50 / 60Hz
Protection Overload, short circuit and phase failure
Mounting type Panel mounting
Application Three-phase motor protection
Standards IEC/EN 60947-1, IEC/EN 60947-2 and IEC/EN 60947-4-1
HS Code 8536209090
Country of Manufacture South Korea

Frequently Asked Questions

What is the IMO C4/100R-63 used for?

It is used to protect three-phase electric motors against overloads, short circuits and phase failure while providing manual motor isolation.

What overload range does this motor protection circuit breaker provide?

The adjustable thermal setting range is 40.0 to 63.0A.

How many poles does the C4/100R-63 have?

The C4/100R-63 is a three-pole motor protection circuit breaker for three-phase motor circuits.

Where is this breaker typically installed?

It is typically installed in industrial motor starter panels, machinery control cabinets and automation systems.

What protection functions are included?

The breaker provides overload protection, short-circuit protection and phase failure protection for electric motors.

Trusted by Industrial Engineers Worldwide

IMO C4 motor protection circuit breakers are trusted by panel builders, OEMs and industrial engineers for dependable motor protection, safe isolation and reliable long-term performance in industrial control systems.