PMV70NA240 - RELE' PROT.RETE 3F/N 208/240V MULTIFUNZ.

PMV70NA240 – RELE’ PROT.RETE 3F/N 208/240V MULTIFUNZ.

Lovato PMV70NA240 self-powered multifunction three-phase voltage monitoring relay for 208–240 V AC systems with or without neutral, providing undervoltage, overvoltage, asymmetry, phase-loss, neutral-loss and incorrect phase-sequence protection.

SKU: PMV70NA240MPN: PMV70NA240
Price
List Price £410.60 ex VAT
Your Price (ex VAT) Save 40%
£246.36 40% OFF
You save £164.24 per unit
Manufacturer Lead Time Please contact us for a delivery time before you order
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £246.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£246.36

Why Choose the Lovato PMV70NA240 Voltage Monitoring Relay?

The Lovato PMV70NA240 is a multifunction three-phase voltage monitoring relay designed to provide comprehensive protection for electrical systems operating with or without a neutral conductor. As part of the Lovato PMV70N monitoring relay series, it combines minimum-voltage, maximum-voltage and voltage-asymmetry monitoring with phase-loss, neutral-loss and incorrect phase-sequence detection.

This self-powered relay continuously supervises a 208–240 V AC three-phase supply and de-energises its output contacts when an abnormal voltage or phase condition is detected. Adjustable voltage, asymmetry and timing controls allow the protection settings to be tailored to motors, machinery, distribution systems and industrial automation equipment.

With adjustable 80–95% undervoltage, 105–115% overvoltage and 5–15% voltage-asymmetry thresholds, the PMV70NA240 combines several essential protection functions within one compact device. Two changeover relay outputs provide flexible shutdown and alarm signalling, while its neutral-loss monitoring is particularly valuable in systems supplying phase-to-neutral loads.

Key Advantages

  • Monitors three-phase 208–240 V AC systems with or without neutral.
  • Detects undervoltage, overvoltage and voltage asymmetry.
  • Provides phase-loss, neutral-loss and incorrect phase-sequence protection.
  • Self-powered operation eliminates the need for a separate auxiliary supply.
  • Independently adjustable voltage and asymmetry thresholds.
  • Adjustable tripping and resetting delays help reduce nuisance operation.
  • Two changeover outputs support separate control, shutdown and alarm circuits.
  • Automatic resetting restores operation when normal supply conditions return.

Key Features

  • Lovato PMV70N multifunction voltage monitoring relay series.
  • 208–240 V AC rated monitoring range.
  • Suitable for three-phase systems with or without neutral.
  • Minimum and maximum AC voltage monitoring.
  • Adjustable voltage-asymmetry monitoring.
  • Phase-loss, neutral-loss and incorrect phase-sequence detection.
  • 80–95% adjustable undervoltage threshold.
  • 105–115% adjustable overvoltage threshold.
  • 5–15% adjustable asymmetry threshold.
  • 0.1–20 second adjustable tripping delay.
  • 0.1–20 second adjustable resetting time.
  • Automatic reset with resetting hysteresis.
  • Two normally energised SPDT changeover relay outputs.
  • Front-mounted potentiometers for straightforward configuration.
  • Green and red LED operating and fault indication.
  • 35 mm DIN rail mounting with screw terminals.

Reliable Three-Phase and Neutral Protection

Undervoltage can cause motors to lose torque, draw excessive current and overheat, while overvoltage can place damaging stress on insulation and electronic equipment. Voltage asymmetry can also produce uneven phase currents, excessive heating and reduced motor efficiency. The Lovato PMV70NA240 monitors all of these conditions from one multifunction relay.

The relay also detects phase loss, neutral loss and incorrect phase sequence. Neutral-loss supervision is especially important where single-phase loads are distributed across a three-phase network, as a disconnected neutral can create damaging voltage imbalance across connected equipment.

Typical Applications

  • Three-phase systems with distributed neutral conductors.
  • Industrial motor protection circuits.
  • Electrical control panels and switchboards.
  • Commercial and industrial distribution boards.
  • Pumps, fans and compressor systems.
  • Production and packaging machinery.
  • HVAC and refrigeration installations.
  • Automation systems requiring separate alarm and control outputs.

Technical Specifications

Tick the specs you need, then view products that match.

Reset Type Automatic
Monitoring Function Three-phase supply
Monitored Supply Three-phase
Time Delay Adjustable
Voltage 240 V
Phase Three Phase
Manufacturer Lovato Electric
Series PMV70N
Model PMV70NA240
Product type Multifunction three-phase voltage monitoring relay
Monitored system Three-phase with or without neutral
Rated control voltage 208–240 V AC
Operating voltage range 0.7–1.2 × Ue
Rated frequency 50 / 60 Hz
Auxiliary supply Self-powered
Programming method Front-mounted potentiometers
Monitoring functions Minimum voltage, maximum voltage, voltage asymmetry, phase loss, neutral loss and incorrect phase sequence
Minimum-voltage set-point 80–95% of Ue
Maximum-voltage set-point 105–115% of Ue
Asymmetry set-point 5–15% of Ue
Tripping delay 0.1–20 seconds
Resetting time 0.1–20 seconds
Reset type Automatic
Number of relay outputs 2
Relay operating state Normally energised, de-energises on trip
Contact arrangement 2 changeover SPDT contacts
Rated operational contact voltage 250 V AC
Maximum switching voltage 400 V AC
Conventional free-air thermal current 8 A
Status indication Green operating LED and red fault LEDs
Terminal type Screw terminals
Maximum terminal tightening torque 0.8 N·m
Conductor size 0.2–4 mm²
Rated insulation voltage 600 V
Rated impulse withstand voltage 6 kV
Operating temperature -20 to +60 °C
Storage temperature -30 to +80 °C
Protection rating IP40 front, IP20 terminals
Mounting type 35 mm DIN rail
Modular width 3 modules
Dimensions (W × H × D) approximately 53.5 × 104.7 × 64.9 mm
Weight approximately 200 g
Conformity IEC/EN 60255-5, IEC/EN 61000-6-2, IEC/EN 61000-6-3 and IEC/EN 60335-2-89
HS Code 85364900

Frequently Asked Questions

What is the Lovato PMV70NA240 used for?

The PMV70NA240 monitors a three-phase 208–240 V AC system for undervoltage, overvoltage, voltage asymmetry, phase loss, neutral loss and incorrect phase sequence.

Can the PMV70NA240 operate without a neutral conductor?

Yes. The relay is suitable for three-phase systems with or without neutral, making it suitable for a wide range of industrial electrical installations.

Does the PMV70NA240 require an auxiliary power supply?

No. The relay is self-powered directly from the monitored electrical supply.

Can the voltage and asymmetry thresholds be adjusted?

Yes. The undervoltage threshold is adjustable from 80% to 95% of Ue, the overvoltage threshold from 105% to 115% of Ue and the asymmetry threshold from 5% to 15% of Ue.

How many output contacts does the PMV70NA240 provide?

The relay provides two SPDT changeover outputs, allowing separate shutdown, alarm or control circuits to be connected.

How is the Lovato PMV70NA240 installed?

The relay mounts onto a standard 35 mm DIN rail and occupies three modular units inside an electrical control panel or switchboard.

Trusted Industrial Voltage Monitoring

Lovato multifunction monitoring relays are widely used by panel builders, machine manufacturers and electrical engineers to provide dependable voltage, phase and neutral protection in industrial electrical systems.