Finder 70.42.8.400.2032 - 70 Series Line Monitoring relays

Finder 70.42.8.400.2032 – 70 Series Line Monitoring relays

Finder 70.42.8.400.2032 is a DIN rail-mounted three-phase voltage monitoring relay for 380–415 V AC supplies, featuring phase failure, phase sequence, phase asymmetry, undervoltage and overvoltage monitoring, two 8 A changeover contacts and an adjustable 0.5–60 second actuation delay.

SKU: 70.42.8.400.2032Alt SKU: 704284002032MPN: 70.42.8.400.2032
Price
List Price £143.50 ex VAT
Your Price (ex VAT) Save 35%
£93.28 35% OFF
You save £50.23 per unit
Manufacturer Lead Time Standard Manufacturer Lead Time 6-8 Weeks, Call For Express Delivery Options
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £93.28
Trade pricing is personalised to your account

Manufacturer Lead Time

£93.28

Why Choose the Finder 70.42.8.400.2032 Three-Phase Voltage Monitoring Relay?

The Finder 70.42.8.400.2032 is an electronic three-phase voltage monitoring relay designed to supervise the condition of industrial three-phase electrical supplies. Part of the Finder Series 70 monitoring relay range, this device detects potentially damaging supply abnormalities, including phase failure, incorrect phase sequence, phase asymmetry, undervoltage and overvoltage.

Designed for three-phase 380–415 V AC, 50/60 Hz electrical systems, the Finder 70.42.8.400.2032 monitors the connected supply and provides two changeover (DPDT) output contacts rated at 8 A at 250 V AC. Its adjustable 0.5–60 s contact actuation delay supports integration into control systems requiring a defined response to supply abnormalities.

With a compact 35 mm DIN rail mounting arrangement, screw terminals, an IP20 protection rating and an operating temperature range of −20 to +60 °C, this monitoring relay is suitable for industrial control panels, motor control centres, electrical distribution equipment and automated machinery installations.

Key Advantages

  • Five monitoring functions: phase failure, phase sequence, phase asymmetry, undervoltage and overvoltage.
  • Three-phase 380–415 V AC monitoring for industrial electrical systems.
  • Two changeover (DPDT) output contacts for flexible control and signalling.
  • 8 A at 250 V AC contact rating for compatible control circuit loads.
  • Adjustable 0.5–60 s contact actuation delay for application-specific response timing.
  • Supply derived from the monitored electrical system, eliminating the need for a separate auxiliary supply in the specified configuration.
  • 35 mm DIN rail mounting for straightforward panel installation.
  • 35 mm housing width for efficient use of control cabinet space.
  • IP20 protection rating for installation within appropriate electrical enclosures.
  • −20 to +60 °C operating temperature range for industrial environments.

Key Features

  • Finder Series 70 electronic monitoring relay.
  • Three-phase voltage supervision.
  • Phase failure detection.
  • Incorrect phase sequence detection.
  • Phase asymmetry monitoring.
  • Undervoltage monitoring.
  • Overvoltage monitoring.
  • Rated three-phase supply voltage of 380–415 V AC.
  • Rated supply frequency of 50/60 Hz.
  • Two independent changeover output contacts (2 CO / DPDT).
  • 8 A output contact rating at 250 V AC.
  • Adjustable contact actuation delay from 0.5 to 60 s.
  • Electronic voltage monitoring operation.
  • DIN rail mounting for industrial control cabinets.
  • Screw-type electrical terminals.
  • IP20 degree of protection.
  • Compact modular housing.

Reliable Three-Phase Voltage and Phase Sequence Monitoring

The Finder 70.42.8.400.2032 helps improve the reliability of industrial electrical installations by continuously supervising the three-phase supply. Abnormal voltage conditions can affect motors, contactors, control equipment and connected machinery, potentially causing unexpected shutdowns, overheating or equipment damage.

Phase failure monitoring detects the loss of a phase in the electrical supply. This is particularly important for three-phase motors, where operation under phase-loss conditions can cause excessive current in the remaining phases and potentially damage the motor.

Phase sequence monitoring identifies an incorrect phase rotation order. In motor-driven applications, incorrect phase sequence can result in unintended reverse rotation, which may be hazardous for pumps, compressors, conveyors and other rotating machinery.

Undervoltage and overvoltage monitoring help identify supply conditions outside acceptable operating limits, while phase asymmetry monitoring detects voltage imbalance between phases. These functions provide useful supervisory information for industrial electrical protection and automation systems.

The relay's two changeover output contacts can be connected to compatible contactor control circuits, alarm indicators or programmable logic controllers. Its adjustable 0.5–60 s actuation delay allows the monitoring response to be configured for the requirements of the installation.

As a monitoring relay, the Finder 70.42.8.400.2032 does not itself provide short-circuit or overload protection. It should be incorporated into a properly designed electrical protection system using appropriately rated contactors, circuit breakers, fuses and other protective devices.

Typical Applications

  • Three-phase industrial electrical supply monitoring.
  • Motor control centres and industrial motor starter panels.
  • Phase failure detection in three-phase machinery.
  • Phase sequence supervision for pumps, compressors and conveyors.
  • Overvoltage and undervoltage monitoring in electrical distribution systems.
  • Industrial automation and PLC-controlled equipment.
  • HVAC and ventilation control installations.
  • Industrial pumping and water treatment systems.
  • Manufacturing machinery and process equipment.
  • Electrical control cabinets and switchgear assemblies.
  • Supply abnormality alarm and signalling circuits.
  • OEM machinery requiring three-phase voltage supervision.

Technical Specifications

Tick the specs you need, then view products that match.

Mounting Type DIN rail
Monitoring Function Three-phase supply
Monitored Supply Three-phase
Manufacturer Finder
Series 70
Type 70.42
Manufacturer part number 70.42.8.400.2032
Product category Voltage Monitoring Relays
Product type Three-phase voltage monitoring relay
Monitored electrical system Three-phase AC
Rated supply voltage 3 × 380–415 V AC
Rated frequency 50/60 Hz
Supply arrangement Powered from monitored electrical system
Monitored conditions Overvoltage, undervoltage, phase failure, phase sequence and phase asymmetry
Output contact configuration 2 CO (DPDT)
Number of changeover contacts 2
Rated output contact current 8 A
Rated output contact voltage 250 V AC
Rated AC-1 switching capacity 2,000 VA
Rated AC-15 switching capacity at 230 V AC 400 VA
Motor load rating at 230 V AC 0.3 kW
Adjustable contact actuation delay 0.5–60 s
Operating temperature −20 to +60 °C
Degree of protection IP20
Mounting method 35 mm DIN rail
Electrical connection Screw terminals
Terminal tightening torque 0.8 Nm
Width 35 mm
Height 88.8 mm
Depth 60.8 mm
EAN / GTIN-13 8012823398945

Frequently Asked Questions

What is the Finder 70.42.8.400.2032 used for?

The Finder 70.42.8.400.2032 is a three-phase voltage monitoring relay used to detect overvoltage, undervoltage, phase failure, incorrect phase sequence and phase asymmetry in industrial electrical systems.

What voltage range does the Finder 70.42.8.400.2032 monitor?

This relay is designed for three-phase 380–415 V AC electrical systems operating at 50/60 Hz.

How many output contacts does this monitoring relay have?

The Finder 70.42.8.400.2032 provides two changeover output contacts (2 CO / DPDT), each with an 8 A rating at 250 V AC.

Can this relay detect incorrect phase sequence?

Yes. The relay monitors phase sequence and can detect an incorrect phase rotation order, making it useful for electrical systems containing three-phase motors and rotating machinery.

Does the Finder 70.42.8.400.2032 detect phase failure?

Yes. Phase failure detection is one of the relay's monitoring functions, allowing the control system to respond when a phase is lost from the monitored supply.

What is the adjustable delay range?

The Finder 70.42.8.400.2032 has an adjustable contact actuation delay of 0.5–60 s, allowing its response timing to be configured for the application.

How is the Finder 70.42.8.400.2032 installed?

The relay is designed for 35 mm DIN rail mounting inside a suitable electrical control enclosure and uses screw-type terminals for electrical connections.

Does this monitoring relay replace a circuit breaker or motor overload relay?

No. The Finder 70.42.8.400.2032 monitors supply conditions and provides relay outputs for control or signalling. It does not replace appropriately rated short-circuit protection, overload protection or electrical isolation equipment.

Designed for Professional Three-Phase Electrical Monitoring

The Finder 70.42.8.400.2032 provides comprehensive three-phase voltage supervision in a compact DIN rail-mounted monitoring relay. With phase failure, phase sequence, phase asymmetry, undervoltage and overvoltage detection, together with two 8 A changeover contacts and an adjustable response delay, it offers a practical solution for electrical engineers, industrial panel builders, automation specialists and maintenance professionals.