Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
Finder 72.01.8.240.5002 is a 230–240 V AC conductive liquid level control relay featuring adjustable 5–450 kΩ sensitivity, filling and emptying functions, a 16 A changeover output, gold-plated contacts for switching signals down to 5 V and 1 mA, selectable 0.5 s or 7 s delay and 35 mm DIN rail mounting for industrial tank and pump control applications.
£62.15
The Finder 72.01.8.240.5002 is a versatile liquid level monitoring and control relay designed for automatic filling, emptying and level supervision of tanks containing electrically conductive liquids. Part of the Finder 72 Series monitoring relay range, it provides reliable liquid level detection for industrial automation, water management, pumping installations and process control systems.
Featuring an adjustable sensitivity range of 5–450 kΩ, this specialised level control relay can detect conductive liquids with relatively low electrical conductivity. Its 230–240 V AC supply, selectable filling or emptying functions and 16 A changeover output contact make it suitable for a wide range of liquid level control applications. The relay can operate with two electrodes for single-level monitoring or three electrodes for minimum and maximum level control.
The Finder 72.01.8.240.5002 also features gold-plated silver nickel (AgNi + Au) output contacts, enabling dependable switching of low-level control signals down to 5 V and 1 mA. This makes it particularly useful for integration with electronic control circuits and the Finder 72.42 pump priority change relay. Its compact 35 mm DIN rail housing, adjustable sensitivity and selectable delay provide a practical solution for industrial tank monitoring and automatic pump control.
The Finder 72.01.8.240.5002 monitors liquid levels by measuring electrical conductivity between sensing electrodes installed inside a tank or reservoir. When the liquid reaches or falls below the selected electrode positions, the relay responds according to its configured filling or emptying function. This allows pumps, valves and control circuits to be operated automatically without requiring continuous manual supervision.
The relay supports two-electrode and three-electrode sensing arrangements. A two-electrode installation can monitor a single liquid level, while a three-electrode configuration provides minimum and maximum level control. In suitable conductive metal tanks, the tank itself may serve as the common electrode, simplifying the sensing arrangement.
Its adjustable 5–450 kΩ sensitivity is particularly valuable when monitoring liquids with varying conductivity. The extended sensitivity range enables the relay to detect liquids with relatively low conductivity, making it more flexible than standard fixed-sensitivity level controllers. Correct sensitivity adjustment depends on the liquid characteristics, electrode installation and electrical conditions.
The filling mode can be used to start a pump when the liquid falls to a minimum level and stop it when the required maximum level is reached. In emptying mode, the relay can operate a pump to remove liquid from a tank or sump when the level rises, stopping the pump once the lower level is reached. These functions help automate water management and reduce unnecessary pump operation.
The selectable 0.5 s or 7 s delay helps prevent unwanted relay switching caused by waves, splashing or temporary changes in liquid contact with the electrodes. Selecting the appropriate delay can improve the stability of pump control systems and reduce unnecessary switching cycles.
A distinguishing feature of the 72.01.8.240.5002 is its gold-plated AgNi + Au changeover contact. Unlike standard contacts intended primarily for larger electrical loads, this version supports reliable switching of low-level signals down to 5 V and 1 mA. This makes it especially suitable for electronic control inputs and applications involving the Finder 72.42 pump priority change relay, where low-current control signals are used to coordinate pump operation.
With its 16 A changeover output, compact DIN rail design and adjustable sensing characteristics, the Finder 72.01.8.240.5002 can form part of a dependable liquid level automation system. Where pumps or other loads exceed the relay's switching capability, a suitably rated contactor or motor starter should be used. The relay is intended for conductive liquids and is not suitable for direct detection of non-conductive liquids such as oils.
Tick the specs you need, then view products that match.
| Terminal Type | Screw | |
|---|---|---|
| Mounting Type | DIN rail | |
| Monitoring Function | Liquid level | |
| Manufacturer | Finder | |
| Series | 72 Series Monitoring Relays | |
| Model | 72.01.8.240.5002 | |
| Product type | Liquid level control relay | |
| Relay type | 72.01 | |
| Monitoring principle | Conductive liquid level detection | |
| Supply voltage | 230–240 V AC | |
| Supply frequency | 50/60 Hz | |
| Rated supply consumption | 2.5 VA | |
| Output configuration | 1 changeover contact (1 CO / SPDT) | |
| Rated output current | 16 A | |
| Rated contact voltage | 250 V AC | |
| Contact material | Silver nickel with gold plating (AgNi + Au) | |
| Minimum switching voltage | 5 V | |
| Minimum switching current | 1 mA | |
| Sensitivity adjustment range | 5–450 kΩ | |
| Low-conductivity detection capability | Down to approximately 2 µS | |
| Operating functions | Filling / emptying | |
| Selectable delay | 0.5 s or 7 s | |
| Electrode sensing voltage | 4 V AC | |
| Electrode sensing current | 0.2 mA | |
| Electrode inputs | 3 | |
| Single-level control | Two-electrode arrangement | |
| Minimum/maximum level control | Three-electrode arrangement | |
| Protection rating | IP20 | |
| Mounting type | 35 mm DIN rail | |
| Connection type | Screw terminals | |
| Housing width | 35 mm | |
| Housing height | 84 mm | |
| Housing depth | 54.6 mm | |
| Operating temperature | −20 to +60 °C | |
| Insulation between supply, contacts and electrodes | Reinforced insulation | |
| Impulse withstand voltage | 6 kV | |
| Compatible control accessory | Finder 72.42 priority change relay | |
| EAN | 8012823364186 |
The Finder 72.01.8.240.5002 is a liquid level control relay used to monitor conductive liquids and automatically control filling, emptying and level alarm functions in tanks, reservoirs, sumps and industrial pumping systems.
The relay operates from a 230–240 V AC supply at 50/60 Hz. It must be connected to an appropriately protected supply circuit in accordance with the manufacturer's installation instructions.
The relay has an adjustable sensitivity range of 5–450 kΩ. This extended range supports monitoring of conductive liquids with relatively low conductivity, including suitable liquids down to approximately 2 µS under specified conditions.
Yes. The relay supports selectable filling and emptying functions. Filling mode can maintain a tank between minimum and maximum levels, while emptying mode can operate a pump to remove liquid when the level rises above the selected threshold.
The relay can operate with two electrodes for single-level monitoring or three electrodes for minimum and maximum level control. In suitable conductive metal tanks, the tank body may be used as the common electrode.
The relay features one 16 A changeover contact (SPDT / 1 CO). The connected load must remain within the applicable contact ratings, and larger motors should be controlled through a suitably rated contactor or motor starter.
This model uses silver nickel contacts with gold plating (AgNi + Au) to improve switching reliability at low electrical loads. It supports control signals down to 5 V and 1 mA, making it suitable for sensitive electronic inputs and compatible pump control relays.
The relay provides selectable 0.5 s and 7 s delay settings. These can help prevent unwanted switching caused by temporary liquid movement, splashing or fluctuations around the sensing electrodes.
Yes. Finder specifically recommends the 72.01.8.240.5002 for certain applications with the Finder 72.42 priority change relay because its gold-plated contacts can reliably switch the low-current control signals used by the pump alternation system.
Both models provide a 230–240 V AC supply and an extended 5–450 kΩ adjustable sensitivity range. The main difference is the output contact material: the 72.01.8.240.5002 has gold-plated AgNi + Au contacts for reliable low-level signal switching down to 5 V and 1 mA, while the 72.01.8.240.0002 uses standard contact material.
No. The relay operates by detecting electrical conductivity between electrodes and is intended for conductive liquids. Non-conductive liquids such as oils generally require a different sensing technology, such as a float switch or another suitable level sensor.
Yes. The relay features a 35 mm wide modular housing designed for DIN rail installation, making it suitable for electrical control panels, pump control cabinets and industrial automation enclosures.
Finder 72 Series monitoring relays provide dependable liquid level control for industrial pumping systems, water treatment equipment and automated tank installations. With adjustable 5–450 kΩ sensitivity, filling and emptying functions, a 16 A changeover output and gold-plated contacts suitable for low-level control signals, the Finder 72.01.8.240.5002 offers a versatile solution for electrical engineers, pump system installers, control panel builders and industrial automation professionals.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.