Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB CM-IWN.1P insulation monitoring relay with a 24–240 V AC/DC control supply, selectable 1–100 kΩ and 2–200 kΩ measuring ranges, two configurable changeover contacts and push-in terminals for continuous insulation supervision of unearthed AC and DC electrical systems.
£474.79
The ABB CM-IWN.1P is a high-performance insulation monitoring relay designed for continuous supervision of insulation resistance in unearthed electrical distribution systems. As part of the ABB CM-IWN insulation monitoring relay series, it provides reliable detection of insulation deterioration and earth faults in industrial AC, DC and combined AC/DC electrical networks.
This multifunctional insulation monitoring relay helps improve electrical safety, equipment availability and preventive maintenance by identifying insulation faults before they develop into more serious electrical problems. The CM-IWN.1P features adjustable insulation resistance thresholds, configurable output contacts, fault memory functionality and interrupted measuring-wire detection. Its advanced measuring principle uses a superimposed square-wave signal to monitor insulation resistance in unearthed IT systems.
With a 24–240 V AC/DC control supply, two selectable insulation resistance measuring ranges of 1–100 kΩ and 2–200 kΩ, and compatibility with unearthed networks up to 400 V AC or 600 V DC, the CM-IWN.1P is suitable for industrial power distribution, machinery, control systems and electrical installations requiring dependable insulation supervision. Its compact DIN rail-mounted design and push-in connection terminals simplify installation inside electrical control panels.
Insulation monitoring relays such as the ABB CM-IWN.1P continuously supervise the insulation resistance between active conductors and earth in unearthed electrical networks. When insulation resistance falls below a configured threshold, the relay provides an output signal that can activate an alarm, initiate a control response or notify maintenance personnel of a developing insulation fault.
Unlike conventional earth fault protection devices used in earthed distribution systems, insulation monitoring devices are specifically designed for unearthed IT electrical networks. These systems can often continue operating after an initial insulation fault, making early fault detection particularly important for maintaining process availability and preventing subsequent electrical failures.
The CM-IWN.1P uses a superimposed square-wave measuring signal to monitor insulation resistance in AC, DC and mixed AC/DC systems. Its selectable measuring ranges, configurable relay outputs and non-volatile fault memory provide flexibility for industrial applications where continuous electrical supervision and dependable fault signalling are required.
For systems operating above the relay's standard monitored voltage range, the compatible ABB CM-IVN.P coupling unit can extend the monitored network voltage capability up to 690 V AC or 1000 V DC when installed according to ABB specifications.
Tick the specs you need, then view products that match.
| Monitoring Function | Insulation |
|---|
The ABB CM-IWN.1P is an insulation monitoring relay used to continuously measure insulation resistance and detect earth faults in unearthed AC, DC and mixed AC/DC electrical distribution systems.
The relay operates from a 24–240 V AC/DC control supply, making it suitable for a wide range of industrial electrical control and monitoring applications.
The CM-IWN.1P monitors unearthed IT electrical systems with nominal voltages up to 400 V AC or 600 V DC. It also supports mixed AC/DC networks with galvanically connected circuits.
The relay provides two selectable insulation resistance measuring ranges of 1–100 kΩ and 2–200 kΩ, allowing the monitoring thresholds to be adjusted for different electrical installations.
The CM-IWN.1P features two changeover relay contacts that can be configured for common or separate signalling, enabling integration with alarm circuits, PLC inputs and industrial control systems.
Yes. The relay includes configurable non-volatile fault memory, allowing insulation fault information to be retained when this function is enabled.
Yes. The CM-IWN.1P includes configurable interrupted-wire detection to help identify problems with the insulation monitoring connections.
The relay uses push-in screwless terminals with ABB Easy Connect Technology, providing secure connections and simplifying wiring during electrical panel installation.
Yes. When used with the compatible ABB CM-IVN.P coupling unit, the monitored system voltage range can be extended up to 690 V AC or 1000 V DC, subject to ABB installation requirements.
The relay is designed for DIN rail mounting inside electrical distribution boards, industrial control panels and automation cabinets where continuous insulation monitoring is required.
ABB CM-IWN insulation monitoring relays provide dependable insulation resistance supervision for unearthed industrial electrical networks. With adjustable measuring ranges, configurable fault signalling, universal control supply compatibility and convenient push-in terminals, the CM-IWN.1P supports safer electrical operation, improved equipment availability and effective preventive maintenance.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.