1SVR740774R1300 ABB CM-PAS.31P Three-Phase Monitoring Relay

1SVR740774R1300 ABB CM-PAS.31P Three-Phase Monitoring Relay

ABB CM-PAS.31P three-phase monitoring relay 1SVR740774R1300 for 160–300 V AC systems with phase failure, phase sequence and adjustable phase-unbalance monitoring, adjustable tripping delay and two changeover outputs.

SKU: 1SVR740774R1300Alt SKU: CM-PAS.31PMPN: 1SVR740774R1300
Price
List Price £220.67 ex VAT
Your Price (ex VAT) Save 35%
£143.44 35% OFF
You save £77.23 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £143.44
Trade pricing is personalised to your account

Manufacturer Lead Time

£143.44

Why Choose the ABB CM-PAS.31P Three-Phase Monitoring Relay?

The ABB CM-PAS.31P is a compact three-phase monitoring relay designed to supervise critical phase conditions in three-phase electrical supplies. Supplied under ABB order code 1SVR740774R1300, it monitors phase failure, phase sequence and phase unbalance to help protect motors, machinery and electrical equipment against unsuitable supply conditions.

The CM-PAS.31P is designed for three-phase systems with a 160–300 V AC line-to-line measuring range, with the measuring voltage also serving as the relay's control supply. The phase-unbalance threshold is adjustable from 2–25%, allowing the protection level to be matched to the requirements of the connected equipment.

An adjustable tripping delay of 0 s or 0.1–30 s helps prevent unwanted operation during brief disturbances, while two changeover (SPDT) output contacts provide flexible integration with contactors, alarms and control systems. Easy Connect push-in terminals and a slim 22.5 mm DIN rail housing simplify installation in industrial control panels.

Key Advantages

  • Monitors phase failure, phase sequence and phase unbalance.
  • Designed for 3 × 160–300 V AC three-phase systems.
  • 2–25% adjustable phase-unbalance threshold for application-specific protection.
  • Adjustable 0 s or 0.1–30 s tripping delay.
  • Fast 200 ms start-up delay.
  • Two changeover (SPDT) contacts provide flexible control and signalling.
  • Measuring voltage also provides the control supply, simplifying wiring.
  • Maintenance-free Easy Connect push-in terminals.
  • Compact 22.5 mm width conserves DIN rail space.
  • Three LEDs provide clear operational-state indication.

Key Features

  • ABB CM-PAS three-phase monitoring relay series.
  • ABB order code 1SVR740774R1300.
  • Phase failure detection.
  • Phase sequence monitoring.
  • Phase unbalance monitoring.
  • 2–25% adjustable phase-unbalance threshold.
  • 160–300 V AC line-to-line measuring range.
  • Rated control supply voltage equal to the measuring voltage.
  • 0 s or 0.1–30 s adjustable tripping delay.
  • 200 ms start-up delay.
  • 2 c/o (SPDT) output contacts.
  • 250 V / 4 A output contact rating.
  • Push-in / screwless terminal technology.
  • Three LED indicators for operational states.
  • Tool-free DIN rail mounting and removal.

Reliable Three-Phase Supply Monitoring

Three-phase motors and machinery can be affected by incorrect phase sequence, loss of a phase or excessive voltage unbalance. The ABB CM-PAS.31P continuously monitors these phase conditions and changes the state of its output contacts when the monitored supply moves outside the configured operating conditions, allowing connected control equipment to initiate an alarm or disconnect the load.

The adjustable 2–25% phase-unbalance threshold allows the relay to be configured for the required level of supply symmetry, while the selectable instantaneous or 0.1–30 s tripping delay helps distinguish persistent faults from short-duration disturbances. This combination provides flexible three-phase protection for motors, pumps, compressors and industrial machinery.

Typical Applications

  • Three-phase motor protection circuits.
  • Pumps, fans and ventilation systems.
  • Compressors and refrigeration machinery.
  • Conveyors and material handling systems.
  • Industrial machinery and production equipment.
  • Motor control centres and electrical control panels.
  • Phase-sequence verification in three-phase installations.
  • Applications requiring phase-failure and phase-unbalance supervision.

Technical Specifications

Tick the specs you need, then view products that match.

Time Delay Adjustable
Monitored Supply Three-phase
Signal / Input Range 3 × 160–300 V AC
Monitoring Function Three-phase supply
Series CM-PAS
ABB order code 1SVR740774R1300
Product group 310921-Measuring & Monitoring Relays
Product type Three-phase monitoring relay
Monitoring functions Phase failure, phase sequence and phase unbalance
Measuring range 3 × 160–300 V AC line-to-line
Rated control supply voltage 3 × 160–300 V AC
Rated frequency 50 / 60 Hz
Phase-unbalance threshold 2–25%, adjustable
Start-up delay 200 ms
Tripping delay 0 s or 0.1–30 s, adjustable
Outputs 2 changeover (SPDT) contacts
Contact rating 250 V / 4 A
Maximum output circuit operating voltage UL/CSA 300 V AC
UL/CSA contact rating B300
Status indication 3 LEDs
Connection technology Easy Connect push-in terminals
Protection rating Housing IP50, terminals IP20
Ambient operating temperature -20 to +50 °C
Storage temperature -40 to +85 °C
Mounting DIN rail
Dimensions (W × H × D) 22.5 × 85.6 × 103.7 mm
Net weight 0.124 kg
EAN / UPC 4016779851978

Frequently Asked Questions

What does the ABB CM-PAS.31P monitor?

The CM-PAS.31P monitors phase failure, phase sequence and phase unbalance in three-phase AC supplies.

What voltage range does the CM-PAS.31P monitor?

The CM-PAS.31P is designed for a 3 × 160–300 V AC line-to-line measuring range, with the measuring voltage also serving as its control supply.

Is the phase-unbalance threshold adjustable?

Yes. The CM-PAS.31P provides an adjustable 2–25% phase-unbalance threshold, allowing the monitoring sensitivity to be matched to the application.

Can the CM-PAS.31P delay tripping after a fault is detected?

Yes. The relay provides a selectable 0 s instantaneous setting or an adjustable 0.1–30 s tripping delay.

What outputs does the CM-PAS.31P provide?

The CM-PAS.31P provides two changeover (SPDT) output contacts rated at 250 V / 4 A for integration with contactors, alarms and control circuits.

Trusted ABB Three-Phase Monitoring Technology

ABB CM-PAS three-phase monitoring relays provide dependable supervision of phase sequence, phase failure and phase unbalance, helping protect motors and industrial equipment from unsuitable three-phase supply conditions.