1SVR550882R9500 ABB CM-PBE Phase Loss Monitoring Relay 380–440 V AC

1SVR550882R9500 ABB CM-PBE Phase Loss Monitoring Relay 380–440 V AC

ABB CM-PBE 1SVR550882R9500 is a 380–440 V AC three-phase phase loss monitoring relay with one normally open output contact for reliable supervision of industrial three-phase mains.

SKU: 1SVR550882R9500Alt SKU: CM-PBEMPN: 1SVR550882R9500
Price
List Price £77.33 ex VAT
Your Price (ex VAT) Save 35%
£50.26 35% OFF
You save £27.07 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £50.26
Trade pricing is personalised to your account

Manufacturer Lead Time

£50.26

Why Choose the ABB CM-PBE Phase Loss Monitoring Relay?

The ABB CM-PBE 1SVR550882R9500 is a compact and reliable three-phase phase loss monitoring relay designed to supervise phase failure in industrial three-phase mains. As part of the ABB CM-PBE three-phase monitoring relay series, it provides a straightforward method of detecting supply faults that could otherwise disrupt or damage motors, machinery and electrical installations.

This CM-PBE version monitors a 380–440 V AC phase-to-phase supply and is powered directly by the measuring circuit, eliminating the need for a separate auxiliary control supply. It is the version without neutral monitoring and is specifically intended for monitoring three-phase mains.

The relay provides one normally open (N/O) output contact and operates according to the closed-circuit principle. A 500 ms start-up delay and 150 ms tripping delay support dependable operation, while its slim 22.5 mm housing, DIN-rail mounting and screw terminals make it well suited to industrial control panels.

Key Advantages

  • Dedicated three-phase phase loss monitoring relay.
  • 380–440 V AC phase-to-phase measuring range for industrial three-phase supplies.
  • Helps protect motors and machinery against phase failure.
  • Powered directly by the measuring circuit with no separate auxiliary supply required.
  • One normally open output contact for control and signalling circuits.
  • Fast 150 ms tripping delay following fault detection.
  • Compact 22.5 mm wide housing conserves DIN-rail space.
  • Screw-terminal connections simplify installation in control cabinets.

Key Features

  • ABB CM-PBE phase loss monitoring relay.
  • Designed for phase failure detection in three-phase mains.
  • 380–440 V AC L-L rated control supply and measuring voltage.
  • Version without neutral monitoring.
  • 1 N/O output contact.
  • Closed-circuit operating principle.
  • 500 ms start-up delay.
  • 150 ms tripping delay.
  • Powered by the monitored measuring circuit.
  • LED indication for operational status.
  • Screw terminals for electrical connections.
  • Compact DIN-rail format for industrial control panels.

Reliable Phase Loss Monitoring for Three-Phase Systems

Phase failure can cause three-phase motors and other electrical equipment to operate incorrectly, overheat or stop unexpectedly. The ABB CM-PBE continuously supervises the three-phase supply and changes the state of its output relay when a phase failure condition is detected, enabling the associated control system to respond appropriately.

Because the CM-PBE is powered directly by the measuring circuit, installation is straightforward and requires no independent auxiliary supply. Its compact construction makes it particularly suitable for panel builders, machine builders and industrial installations where dependable phase supervision is required without occupying excessive DIN-rail space.

Typical Applications

  • Three-phase motor protection circuits.
  • Industrial machinery and production equipment.
  • Pumps, compressors and ventilation systems.
  • Phase failure detection in electrical distribution systems.
  • Industrial automation and machine control panels.
  • Conveyors and material handling equipment.
  • Three-phase power supply supervision.

Technical Specifications

Tick the specs you need, then view products that match.

Time Delay Fixed
Monitored Supply Three-phase
Signal / Input Range 380–440 V AC
Monitoring Function Three-phase supply
Series CM-PBE
ABB order code 1SVR550882R9500
Product type Phase loss monitoring relay
Monitoring function Phase failure detection
Rated control supply voltage 380–440 V AC L-L
Measuring range 380–440 V AC L-L
Rated frequency 50 / 60 Hz
Neutral monitoring No
Output 1 normally open contact
Operating principle Closed-circuit principle
Start-up delay 500 ms
Tripping delay 150 ms
Supply principle Powered by measuring circuit
Terminal type Screw terminals
Mounting type DIN rail
Product width 22.5 mm
Product height 78 mm
Product depth 78.5 mm
Net weight approx. 0.066 kg

Frequently Asked Questions

What is the ABB CM-PBE 1SVR550882R9500 used for?

It is a three-phase phase loss monitoring relay designed to detect phase failure in industrial three-phase electrical supplies.

What voltage range does this CM-PBE monitor?

ABB order code 1SVR550882R9500 monitors a phase-to-phase voltage range of 380–440 V AC.

Does the ABB CM-PBE 1SVR550882R9500 monitor the neutral conductor?

No. This specific CM-PBE version is designed without neutral monitoring and monitors the three phase conductors.

What output does the CM-PBE provide?

The relay provides one normally open contact operating according to the closed-circuit principle for integration with industrial control and protection circuits.

Does the CM-PBE require a separate auxiliary supply?

No. The CM-PBE is powered directly by the measuring circuit, so a separate auxiliary control supply is not required.

Trusted ABB Monitoring Technology

ABB CM series measuring and monitoring relays provide dependable supervision of electrical parameters in industrial systems, helping machine builders, panel builders and operators protect equipment and maintain reliable operation.